background image

10 

1.      Transmission window

 

2.      Liquid crystal display

 

3.      Mode select key:

 

 Select from among the three functions: cooling, heating and dehumidifying. The fast key          
 function indicates the above operating modes in a cycle when the key is pressed without    
 being released. However, the transmission icon will not appear until the key is released and     
 the confirmed mode is transmitted. 

 

4.     Setting keys for room temperature:

 

The set temperature will rise by 1°F when the 

 key is pressed once and the set temperature  

will fall by 1°F when the 

 key is pressed once. Both keys have the fast key function and can 

make the set temperature rise or fall continuously when the keys are pressed without release. 

 

5.     Power key:

 

When this key is pressed, the memorized modes and other information about temperature, 
speed, direction of airflow, sleep, etc., in the remote control will be transmitted to the unit and 
it will operate correspondingly. When the key is pressed again, the main unit will stop 
immediately. 

 

6.     Sleep key

 

When this key is pressed, the air flow of the unit changes into sleep mode (low speed). 

 

   (1)  Press “SLEEP” key, set sleep function; press again, and cancel sleep setting.  

 

   (2)  The temperature will increase 2°F half an hour after setting sleep function, and will 

increase  at most 4°F every two hours after that. 

 

(3)  When the main power supply is cut off, the sleep function setting will be cancelled 

automatically. 

 

(4)  When you turn off the unit, sleep function setting will be cancelled automatically. 

 

 

REMOTE CONTROL FUNCTIONS 

Содержание ZoneAire Compact P08S

Страница 1: ...ety Guidelines 2 Introduction 3 Unpacking Instructions Contents 4 Parts 5 Display Functions 6 Remote Control Functions 9 Drain Pipe 12 Maintenance Cleaning 13 Installation 14 Troubleshooting 16 P08S P...

Страница 2: ...minutes before restarting this is to prevent the compressor from being damaged This unit is for indoor cooling heating and dehumidifying When turning on the unit the fan will operate but the compresso...

Страница 3: ...Offers cooling dehumidification bonus heat for year round conditioning and comfort Innovative design One side offers cooling simply turn the unit around and apply the exclusive heat clip for bonus hea...

Страница 4: ...se 4 Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam base 5 Lift and lean the unit slightly to take out exhaust hose from unit s bottom as...

Страница 5: ...PARTS 1 Control panel 2 Remote control receiver 3 Hot air outlet 4 Evaporator s filter 5 Cool air inlet 6 Air outlet s joint part 7 Cool air outlet 8 Condenser s filter 9 Hot air inlet 10 Drain hole 5...

Страница 6: ...ion This key lowers the preset temperature by 1 F each time it is pressed and the minimum limit is 63 F During heating function This key lowers the preset temperature by 1 F each time it is pressed an...

Страница 7: ...it automatically after the set time is over 1 Press the TIMER key at stand by status to set the time you desired 2 Once the set hour has come to an end the unit will turn on automatically 3 Press the...

Страница 8: ...ter 2 hours 3 Press the SLEEP key again to cancel the setting 9 ALARM When the water tank is full E4 will be displayed on the display panel To resume operation please remove the rubber cap of the drai...

Страница 9: ...9 REMOTE CONTROL FUNCTIONS Instruction for the operating keys When a remote control signal is transmitted a transmission icon on the display flashes once indicating the signal has been transmitted...

Страница 10: ...the keys are pressed without release 5 Power key When this key is pressed the memorized modes and other information about temperature speed direction of airflow sleep etc in the remote control will be...

Страница 11: ...will turn on TIMER OFF The timer off is used to turn off the unit automatically after the set time is over 1 Press the TIMER key at stand by status to set the time desired 2 Once the setting hour has...

Страница 12: ...ain pipe should be installed in order to improve heating 3 When operating the dehumidifying function the rubber cap on drain hose should be pulled out and proper drain hose should be installed Please...

Страница 13: ...ensuring all dust is removed CONDENSER EVAPORATOR Use a brush attachment with a vacuum cleaner CASING Wipe with a damp cloth and polish with a soft cloth To remove the air filter please follow the ar...

Страница 14: ...cut off device Please ensure the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect its performance dramatically Do not overextend the exh...

Страница 15: ...shown in Fig 01 2 As shown in Fig 02 slide the heat clip connector onto the cooling outlet side of the unit 3 As shown in Fig 03 attach the exhaust hose directly onto the onto heat clip connector 4 R...

Страница 16: ...Amps 9A 11A Moisture Removed 63 4 Pints Day 84 5 Pints Day Refrigerant R410A 15 9 ozs 450g R410A Dimensions 11 1 3 W 288mm x 16 6 7 D 428mm x 25 1 5 H 640mm CE N 842 2006 R410A is a kind of fluorinat...

Страница 17: ......