Control Panel Operation

Dehumidifying and cooling operation

The operating range for cooling operation is 63°F - 88°F (or 
17°C - 31°C) and the operating range for dehumidifying is 
68°F - 88°F (or 20°C - 31°C).

Power source

•  The AC socket must be fi rm and reliable.

•  Don’t connect the portable air conditioner to a multiple socket 

outlet which is also being used for other electrical appliances.

•  Insert the AC power plug securely into the AC socket before 

using the unit, when it beeps after two seconds, press ON/
OFF button, the unit begins to run.

LCDI power cord information

All Friedrich portable air conditioners are shipped from the 
factory with a Leakage Current Detection Interrupter (LCDI) 
equipped power cord. The LCDI device meets the UL and NEC 
requirements for cord connected air conditioners effective Au-
gust 2004.

To test your power supply cord:
1.   Plug power supply cord into a grounded 3 prong outlet.

2.  Press RESET (See drawing below).

3.  Press TEST (listen for click; Reset button trips and pops 

out).

4.  Press and release RESET (listen for click; Reset button 

latches and remains on). The power supply cord is ready for 
operation.

NOTE: LCDI device is not intended to be used as a switch.

Once plugged in the unit will operate normally without the need 
to reset the LCDI device.

If the device fails to trip when tested or if the power supply cord 
is damaged it must be replaced with a new supply cord from the 
manufacturer. We recommend you contact our Technical Assis-
tance Line at (800) 541-6645. To expedite service, please have 
your model and serial number available.

Cooling operation

1.  Press MODE button to choose the cooling mode, LCD 

window will show “cool”.

 

During the cooling operation, always place the air exhaust 
hose through an open window.    

2.  Repeatedly press TEMP+ or TEMP- button to set a proper 

room TEMP. between 63°F - 88°F. 

3.  Press FAN SPEED button to choose a proper fan speed: 

high, middle, low speed.

4.  Press  SWING button to adjust the air delivery direction, The 

LCD window will show “ 

 ”.

NOTE:

In order to improve the cooling effi ciency:
a)    If  your  room  is  directly  exposed  to  the  sun,  draw  the  cur-

tains.

b)  Do not place near other heat source.

Dehumidifying Operation

1.   Keep the windows and the doors closed to aid in effectively 

dehumidifying the room.

2.   Press MODE button to choose the dehumidifying mode, LCD 

window will show  “DRY”, the fan speed cannot be adjusted.

When used as dehumidifi er only it is not necessary to install the 
exhaust hose.

TEST

RESET

Test Button

Reset Button

Time Set Function

To set the time to start the machine, with the unit off (but pow-
er supplied), press TIMER button, the LCD window will show 

”, continually press the TIMER button, set the preferred 

start time.  The setting range is 1-12 hours.

To set the time to stop the machine, with the unit running, press 
TIMER button, the LCD window will show “

”, continually 

press the TIMER button ,set the preferred time to stop the ma-
chine.  The setting range is 1-12 hours

NOTE: During timer mode, if the TIMER button is pressed again, 

it will cancel the timer operation.

WARNING: NEVER CUT OR REMOVE THE GROUNDING 
PRONG FROM PLUG. NEVER USE EXTENSION CORDS TO 
OPERATE AN AIR CONDITIONER.

Содержание ZoneAir P-12

Страница 1: ...Portable Air Conditioner Model P 12 Installation Operation Manual Rev 6 07...

Страница 2: ...fe prac tice which can result in severe personal injury or death This symbol refers to a hazard or unsafe prac tice which can result in personal injury or prod uct or property damage Table of Contents...

Страница 3: ...3 Unit Identification and Function Front Back Lower air intake grille Lower air intake grille Upper air intake grille Hot air outlet Base stopper Condensate pump hose connection...

Страница 4: ...either auto swing or fixed direction mode Display FAN SPEED Button Choose high medium or low fan speed ON OFF Button TIMER Button Set the time for switch on switch off or to clear the timer WATER FUL...

Страница 5: ...e When batteries are inserted the time is automatically set to 12 00 AM EX Set to 10 30 AM Press this button to select auto swing or fixed air delivery Press this button to choose high medium or low s...

Страница 6: ...ine at 800 541 6645 To expedite service please have your model and serial number available Cooling operation 1 Press MODE button to choose the cooling mode LCD window will show cool During the cooling...

Страница 7: ...ue to function normally with the internal recirculation pump run ning to evaporate the water You may hear the pump run at times 3 If the water level is in the high area the unit will function nor mall...

Страница 8: ...ere any other heat source in the room Move the unit away from heat source Are air filters dirty Clean the air filter Is SET TEMP suitable Set to a suitable temperature Is indoor fan speed set at low S...

Страница 9: ...e as straight and horizontal as possible Instructions to install hose If the hose becomes disconnected from the hose fitting it must be reinserted Fit the hose to the hose fitting then rotate it 2 3 r...

Страница 10: ...ndow kit installation Your window kit has been designed to fit most standard verti cal and horizontal window applications However it may be necessary for you to improvise modify some aspects of the in...

Страница 11: ...inage hole in the back of the unit Installation accessories Flexible exhaust hose with adapters 1 set Stretches from 19 1 2 50cm up to 78 3 4 200cm overall Window exhaust adapter flat mouth 1pc Adjust...

Страница 12: ...2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or mainten...

Отзывы: