background image

USC Sleeve/Standard Grille 

       USC Sleeve/Replacement Grille*

stanDarD grille – expanded aluminum

For use with USC sleeve. (Ships with USC sleeve).

*replaCement grille – high-tech plastic

For use on existing sleeves without any grille.  (Ships with 
chassis).

important note: 

When installing into an existing sleeve, consult Installation 
Section of your Installation/Operation Manual to determine 
whether or  not the grille needs to be replaced and/or a 
baffle adapter should be used. 

Installation Accessories (WallMaster only)

DK / Drain Kit

Installed at the back of the unit and allows 

for attachment to permanent  condensate 

disposal system, if disposal is necessary 

or desired.

SB / Sub Base

Used as a base for the unit when 

it is desired to place the cord and 

receptacle within the installation, or 

simply as a base for the unit when 

mounted low in the wall.

BAK / Baffle Adapter Kit

Necessary when installing in a sleeve 

deeper than 16 3/4" deep, such as 

Fedders B sleeve (19 3/4" deep).

IDK / Internal Drain Kit

New construction applications  where 

a condensate drain system has been 

built into the wall interior.

16 3/4"

Fedders B

19 3/4”

important: 

Operating the air conditioner 
with incorrect rear grille or 
without Baffle Adapter Kit 
(on 19 3/4” deep sleeve) will 
recirculate discharge air and 
cause compressor overload 
to trip.

CORRECT Vertical Louvers

INCORRECT Horizontal Louvers

WSC Sleeve/Standard Grille  WSC Sleeve/Optional Architectural Grille, AG

Model

Height

Width   Depth

Depth 

with  

Front

Minimum 

Extension 

Into Room

Minimum 

Extension  

Outside

Thru-the-wall 

Finished Hole

Height

Width

WALLMASTER

WSC Sleeve 
Chassis

16 3/4"

27"

16 3/4"

23"

7 1/2"

 9/16"

17 1/4"

27 1/4"

15 3/4" 26 1/2"

21"

UNI-FIT

USC Sleeve

15 1/2" 25 7/8"

16 3/4"

20 1/2"

 1/2"

15 3/4"

26 1/8"

US Chassis

14 3/8"

24"

20 1/8"

3 3/4"

UE Chassis

14 3/8" 24 5/8"

19 5/8"

3 1/2"

important:

•  Sleeves are sold and shipped separately to accommodate 

new construction and replacement requirements

Sleeve/Chassis Dimensions

Exterior Grilles 

Exterior Grilles

 

When should you 

install a solid side 

sleeve?

SOLID SIDE wall sleeve 

allows for installation in thick 

exterior walls where the 

installation of room air units 

with side vents would effect 

performance and may even 

void the warranty.

Commercial 

and residential 

applications

ROOM AIR CONDITIONER

Blocked side vents restrict air flow

FRIEDRICH THRU-THE-WALL

Solid-side sleeve (no side vents)

Содержание Uni-Fit UE08A13B

Страница 1: ...THRU THE WALL AIR CONDITIONERS cool only heat pumps electric heat ...

Страница 2: ...y cycling the fan with the compressor Smart Fan auto adjusts fan speed to maintain desired temperature Auto memory backup REMOTE CONTROL features The Most Energy Efficient Solid side Air Conditioner Installs in existing 27 sleeves Units are shown installed in WSC sleeve sold and shipped separately Sleeve Dimensions Friedrich WSC Sleeve Fedders A Sleeve Fedders B Sleeve Height inches 16 3 4 16 3 4 ...

Страница 3: ...air exhaust Auto re start Washable reusable filter Seacoast protection HEAT COOL MODELS feature mechanical controls two cooling speeds two heating speeds plus one fan only setting COOLING MODELS feature electronic controls with remote control Money Saver setting that saves energy by cycling the fan with the compres sor and three cooling three fan only speeds TWO EnergyStar models 12 hour programma...

Страница 4: ... in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty Commercial and residential applications ROOM AIR CONDITIONER Blocked side vents restrict air flow FRIEDRICH THRU THE WALL Solid side sleeve no side vents ...

Страница 5: ...inasleeve deeper than 16 3 4 deep such as Fedders B sleeve 19 3 4 deep IDK Internal Drain Kit Newconstructionapplications where a condensate drain system has been built into the wall interior 163 4 FeddersB 193 4 IMPORTANT Operating the air conditioner with incorrect rear grille or without Baffle Adapter Kit on 19 3 4 deep sleeve will recirculate discharge air and cause compressor overload to trip...

Страница 6: ...12 0 1415 9 5 3 3 295 112 WS10B30A 10000 10000 230 208 4 6 5 0 1005 996 10 0 10 0 2 1 260 101 WS13B30B 12500 12000 230 208 6 3 6 7 1404 1379 8 9 8 7 3 3 280 109 WS16B30A 15800 15000 230 208 7 8 8 5 1756 1705 9 0 8 8 4 2 290 119 WE10B33C 10000 10000 11000 9100 230 208 4 6 5 0 1005 996 16 0 14 7 3550 2950 10 0 10 0 2 1 260 103 WE13B33C 12500 12000 11000 9100 230 208 6 3 6 7 1404 1379 16 0 14 7 3550 ...