—18—
3.3 TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two causes.
One is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning
caused by a defect in the refrigeration circuit and/or improper application.
Unit is running but cooling is ineffective
Ineffective Cooling
Check outdoor coil
(heat exchanger) & the fan
operation.
Check gas leakage.
Repair gas leak.
Replacement of unit if the
unit is beyond repair.
Satisfactory operation with
temperature difference of
inlet & outlet air ; 18-26
°
F
Check heat load increase.
Unexpected residue
Overloaded Circuit
Check inside gas pressure.
Adjusting of refrigerant
charge
Malfunction of compressor
Replacement of
compressor
Check cold air circulation
for smooth flow.
Dirty indoor coil
(Heat exchanger)
Malfunction of fan
Clogged air filter
Obstruction at air outlet
Correct above troubles
Check for a clog in
refrigeration circuit.
Repair for a clog in
refrigeration circuit.