(Heat Pump & Electric Heat Models)
An e
ight position control switch i
s used t o
regulate the
operation
of t
he
fan motor and
compresso
r.
The compresso
r
can b
e
operated with the
fan
operating
at l
ow, medium
or
high speed in the cooling or heating mode. The fan motor
can
also
be operated independently
on
medium speed.
See
switch section as indicated on decorative control panel
.
NOTE:
Heat
pump
models
with
e
lectric heat
-
i
n
the heat
position, heating
element
only will b
e
energized whe
n
outdoor t
emperature is below
t
he operating range
of
the
heat pump.
Figure
Figure
Figure
System Control Panel
Heat Pump & Electric Heat Models
(YS, ES, YM, EM, YL & EL)
SYSTEM CONTROL SWITCH - TEST
Disconnect
leads from
control switch. T
urn
c
ontrol to
positio
n
being tested. There must be continuity as follows:
1. “
Of
f” Position - no continuity between terminals.
2.
“ Lo
C
ool” Position
-
between
t
erminals “C”
and
“3”, “C2”
and “2”, “LO” and “M/S”, “AR” and “5”.
3. “
Med
Cool” Position
-
between
t
erminals “C”
and
“3”,
“C2” and “2”, “M” and “M/S”, “AR” and “5”.
4.
“ Hi
C
ool” Position
-
between
t
erminals “C”
and
“3”, “C2”
and “2”, “H” and “M/S”, “AR” and “5”.
System Control Switch
(Heat Pump / Electric
Heat Models
5. “ Hi
H
eat” Position
-
between
t
erminals “C”
and
“1”, “C2”
and “4”, “H” and “M/S”, “AR” and “5”.
6. “
Med
Heat” Position
-
between
t
erminals “C”
and
“1”,
“C2” and “4”, “M” and “M/S”, “AR” and “5”.
7. “ Lo
C
ool” Position
-
between
t
erminals “C”
and
“1”, “C2”
and “4”, “LO” and “M/S”, “AR” and “5”.
8.
“ Fan Only” Position - between terminals “L1” and “M”.
TESTING ThE rOTArY CONTrOL SWITChES
Allow 3 min. between restarts
Money Saver
®
MAX
COOL
MAX
HEAT
Low
Cool
Med
Cool
High
Cool
Low
Heat
Med
Heat
High
Heat
Fan
Only
Yes
No
KS, KM, SL Models
A
six position c
ontrol s
witch is
used to r
egul
ate
the operation
of t
he
fan motor and
compresso
r.
The compressor ca
n
be
operated w ith the
fan
operating
at l
ow, medium
o r
high
speed. The
fan motor
ca
n also
b
e
operated independently
on m
edium speed.
See
switch
s
ection
a s
indica
ted on
de
corati
ve
control panel.
System Control Panel (KS, KM, SL)
Allow 3 min. between restarts
S P E E D
Sleep
Setting
Low
Cool
Medium
Cool
High
Cool
Fan
Only
MIN
MAX
Money Saver
®
Yes
No
19
12
13
14
(See Figure 14)
(See Figure 13)
(See Figure 12)
ELECTRIC SHOCK HAZARD
WARNING
Disconnect power to the unit before
servicing. Failure to follow this warning
could result in serious injury or death.
Содержание Twintemp
Страница 51: ...ELECTRONIC CONTROL COOL ONLY MODELS XQ05L10A C XQ06L10A C XQ08L10A B A E XQ10L10A C XQ12L10A B A C 49...
Страница 53: ...ELECTROMECHANICAL CONTROL COOL ONLY MODELS KS12L10 E F KS15L10 C D KM18L30 C D KM24L30 C D 51...
Страница 54: ...ELECTROMECHANICAL CONTROL COOL ONLY MODELS SL28L30 D E SL36L30A D A E 52...
Страница 55: ...ELECTROMECHANICAL CONTROL COOL WITH ELECTRIC HEAT MODEL EQ08L11A B A E 53...
Страница 56: ...ELECTROMECHANICAL CONTROL COOL WITH ELECTRIC HEAT MODELS ES12L33 D E ES16L33 C D EM18L34 C EM24L34 B 54...
Страница 57: ...ELECTROMECHANICAL CONTROL COOL WITH ELECTRIC HEAT MODELS EL36L35A D A E 55...
Страница 58: ...ELECTROMECHANICAL CONTROL HEAT PUMP ONLY MODELS YS09L10 F G 56...
Страница 59: ...ELECTROMECHANICAL CONTROL HEAT PUMP WITH ELECTRIC HEAT MODELS YS13L33 D E YM18L34 D E 57...
Страница 60: ...ELECTROMECHANICAL CONTROL HEAT PUMP WITH ELECTRIC HEAT MODELS YL24L35 E F 58...
Страница 66: ......