background image

Model

Circuit Rating 

Breaker or

T-D Fuse

Plug Face 

(NEMA#)

Wall Outlet 

Appearance

CP05, CP06, CP08, CP10, CP12 and CP14. 
All XQ MODELS.
KS12L10 and KS15L10. SS08L10, SS10L10, 
SS12L10 and SS14L10. EQ08L11A. YS09L10.

125V - 15A

5 - 15P

CP18. KM18L30.
SS12L30, SS16L30, SM18L30A and SM21L30.

250V - 15A

6 - 15P

CP24. KM24L30. SM24L30 and SL28L30.  
ES12L33 and ES16L33. YS13L33. 

250V - 20A

6 - 20P

SL36L30A.  EM18L34, EM24L34 and EL36L35A. 
YM18L34 and YL24L35.

250V - 30A

6 - 30P

Installation Information / Sleeve Dimensions

† 

Sleeve P1 does not have thru-the-wall hole dimensions, as these units are fixed chassis and should not be installed thru-the-wall.

Circuit rating/ Breaker

TWINTEMP

®

 models include accessories for thru-the-wall 

installation only. Window mounting requires use of optional 

accessory kit as listed above.

Window Mounting Kits

room air Conditioner Model Identification Guide

S L 28 L 3 0 A

FUNCTION
S
–Straight Cool 

C–Straight Cool 

X–Straight Cool 

K–Straight Cool

Y–Heat Pump 

E–Electric Heat

CHASSIS
Q
–Portable 

P–Programmable

S–Small Chassis 

M–Medium Chassis 

L–Large Chassis 

 

 

MODEL SERIES

APPROXIMATE

BTUS (000) Cooling

VOLTAGE

1–115 Volts  3–230/208 Volts

0 – Straight Cool and

    115V Heat Pump Models

1 – 1 KW heat strip, Nominal
3 – 3 KW heat strip, Nominal
4 – 4 KW heat strip, Nominal
5 – 5 KW heat strip, Nominal

Letter at end of model number indicates 

a modification to an existing model.

Sleeve

Height

Width  

Depth

 

with Front

Depth

Hood to

Louvers

Minimum

Extension

Into Room

Minimum

 

Extension

Outside

Window Width

Thru-the-wall

Finished Hole

Minimum

Maximum

Height

Width

Q

14"

19 ¾"

21 

3

8

"

8 ½"

5 ½"

10 ¾"

26"

42"

14 ¼"

20"

  P1†

12 ¼"

18 ½"

15"

5"

3 ½"

10 ¾"

22"

36"

NOT FOR THRU-WALL

P4

17 ½"

26"

27 

5

8

"

7

8

"

5 ½"

16 

5

8

"

27"

42"

17 ¾"

26 ¼"

P5

17 ½"

26"

29 ¾"

7

8

"

5 ½"

19 ½"

27"

42"

17 ¾"

26 ¼"

P6

13 

5

8

"

18 ½"

20 

5

8

"

1

8

"

4 ½"

11"

22"

36"

13 

7

8

"

18 ¾"

P7

15"

23 

5

8

"

22 

1

8

""

8 ¾"

4 ½"

12

27"

39"

15 ¼"

23 

7

8

"

S

15 

15

16

"

25 

15

16

"

27 

3

8

"

8 ¾"

1

16

"

16 

15

16

"

27  

7

8

"

42"

16 

3

16

"

26 

3

16

"

M

17 

15

16

"

25 

15

16

"

27 

3

8

"

8 ¾"

1

16

"

16 

15

16

"

27 

7

8

"

42"

18 

3

16

"

26 

3

16

"

L

20 

3

16

"

28"

33 

5

8

"

16 ½"

3

16

"

18 

15

16

"

29 

7

8

"

42"

20 

3

8

"

28 ¼"

TwinTemp Model

Kit No.

EQ08L11A

WIKQ

ES12L33, ES16L33, YS09L10 and YS13L33.

WIKS

EM18L34, YM18L34 and EM24L34.

WIKM

EL36L35A and YL24L35.

WIKL

Содержание Twin Temp EM24L34

Страница 1: ...ROOM AIR CONDITIONERS cool only heat pumps electric heat...

Страница 2: ...n the sound of rainfall 50 db SS10 sound power rating on low fan speed Extra thick rubber grommets Absorbs motion and sound to reduce unwanted noise Vibration isolator Vibration and noise isolating te...

Страница 3: ...ompressor stops saving money by operating only when required High tech fins Sine wave lanced louvers increase energy efficiency by increasing surface area for heat exchange Rifled copper tubing Greate...

Страница 4: ...n only when the compressor is running Select the SMART FAN setting and your Friedrich will automatically adjust the fan speed to deliver a constant comfortable temperature in any environment Built to...

Страница 5: ...cycling the fan with the compressor Memory backup saves settings if power is interrupted Check filter reminder light DELUXE FEATURES Ultraquiet operation 8 way air flow control Fresh air intake stale...

Страница 6: ...solution Want to clear the room of stale air or cooking smoke Slide the vent lever to EXHAUST and set the fan to FAN ONLY out goes the bad air Sometimes the air outside is cooler than the air inside...

Страница 7: ...ng speeds plus fan only setting Heat anticipating thermostat 8 way air flow control Defrost control heat pumps Fresh air intake and stale air exhaust vents Rotary controls Washable antimicrobial filte...

Страница 8: ...10 8 REMOTE CONTROL 12 HR TIMER MONEY SAVER FEATURE SLIDE OUT CHASSIS Four EnergyStar models F R I E D R I C H CP R O O M A I R C O N D I T I O N E R S RESIDENTIAL GRADE programmable control models C...

Страница 9: ...ide out chassis for easy window or wall installation Expandable side curtains included Easy access lift out filter 14 000 to 23 500 BTU h EERs up to 9 8 quality that lasts that s Friedrich Have a Frie...

Страница 10: ...16200 15900 230 208 7 4 8 0 1653 1656 9 8 9 6 4 7 360 S 119 SM18L30A 17500 17300 230 208 7 2 7 7 1620 1570 10 8 10 8 4 5 375 M 163 SM21L30 20600 20200 230 208 9 4 10 1 2081 2020 9 9 10 0 6 0 425 M 15...

Страница 11: ...t CHASSIS Q Portable P Programmable S Small Chassis M Medium Chassis L Large Chassis MODEL SERIES APPROXIMATE BTUS 000 Cooling VOLTAGE 1 115 Volts 3 230 208 Volts 0 Straight Cool and 115V Heat Pump Mo...

Страница 12: ...r Conditioners Energy efficient and extremely quiet Friedrich PTACs offer programmable electronics with a large LED display that provides precise temperature control and energy savings Installs thru t...

Отзывы: