background image

En-9

  To Cancel the Timer

Use the TIMER button to select “TIMER
RESET.”
The air conditioner will return to normal
operation.

  To Change the Timer Setting

1. Follow the instructions given in the

section “To Use the ON Timer or OFF
Timer” to select the timer setting you
wish to change.

2. Press the TIMER button to select either

OFF 

=

 ON or OFF 

+

 ON.

To Stop Air Conditioner Operation while
the Timer is Operating

Press the START/STOP button.

  To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting),
after making the timer setting wait until the
entire display reappears, then press the
a p p r o p r i a t e   b u t t o n s   t o   c h a n g e   t h e
operating condition desired.

  To Cancel the Timer

Use the TIMER button to select “TIMER
RESET.”
The air conditioner will return to normal
operation.

  To Change the Timer Setting

Perform steps 2 and 3.

To Stop Air Conditioner Operation while
the Timer is Operating

Press the START/STOP button.

  To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting),
after making the timer setting wait until the
entire display reappears, then press the
a p p r o p r i a t e   b u t t o n s   t o   c h a n g e   t h e
operating condition desired.

  To Use the ON timer or OFF timer

Press the START/STOP button (Fig. 6 

¡

).

(if the unit is already operating, proceed to step 2).

The indoor unit’s  OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

Press the TIMER button (Fig. 6 

_

) to select the OFF timer

or ON timer operation.

Each time the button is pressed the timer function changes in the following
order:

TIMER OPERATION

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See Page

 

6).

1

3

RESET  

OFF

ON

PROGRAM (OFF     ON, OFF      ON)

The indoor unit’s TIMER Indicator lamp (green) (Fig. 3 

6

) will light.

Use the SET TEMP.SET TIME  button (Fig. 6 

(

) to adjust

the desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue for
about five seconds).

 

 button: Press to advance the time.

 button: Press to reverse the time.

About five seconds later, the entire display will reappear.

2

  To Use the Program timer

Press the START/STOP button(Fig. 6 

¡

).

(if the unit is already operating, proceed to step 2).

The indoor unit’s  OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON Timer or OFF Timer” to set the desired mode
and times.
About three seconds later, the entire display will reappear.
The indoor unit’s  TIMER Indicator Lamp (green) (Fig. 3 

6

) will light.

Press the TIMER button (Fig. 6 

_

) to select the PROGRAM

timer operation (either OFF 

=

 ON or OFF 

+

 ON will

display).

The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.

÷

The PROGRAM timer will begin operation. (If the ON timer has been
selected to operate first, the unit will stop operating at this point).

About five seconds later, the entire display will reappear.

1

2

  About the Program timer

÷

The PROGRAM timer allows you to integrate OFF timer and ON timer operations
in a single sequence. The sequence can involve one transition from OFF timer to
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

÷

The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Control Unit’s
display (OFF 

=

 ON, or OFF 

+

 ON).

÷

One example of Program timer use might be to have the air conditioner
automatically stop (OFF timer) after you go to sleep, then start (ON timer)
automatically in the morning before you arise.

3

Содержание MR09C1E

Страница 1: ...N MANUAL FOR FUTURE REFERENCE P N9309278028 02 OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit MW09C1E MW12C1E Outdoor Unit MR0...

Страница 2: ...Refer to the fold out page on the cover...

Страница 3: ...g 5 Fig 1 Fig 2 Fig 3 Fig 4 0 9 3 SLEEP TIMER MASTER CONTROL SET TEMP SET TIME FAN CONTROL START STOP SWING LOUVER CLOCK CLOCK TIMER RESET AM PM PM OFF ON H M COOL DRY FAN AUTO HIGH MED LOW QUIET AUTO...

Страница 4: ...ARNING have the following meanings in these instructions WARNING Do not attempt to install this air conditioner by yourself Consult authorized service personnel for all installations Consult authorize...

Страница 5: ...bjects on the air conditioner Personal injury could result from a falling object or if the unit tips over Do not set flower vases or water contain ers on top of air conditioners Water leaking inside t...

Страница 6: ...ely wash with copious amounts of water and consult your physician Install the indoor unit and remote control unit at least one meter from any television sets or radio Signal radiation could be induced...

Страница 7: ...ly turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up...

Страница 8: ...the test operation mode press the START STOP button to stop the air conditioner Remote Control Unit Display Fig 8 Transmit Indicator Clock Display Operating Mode Display Timer Mode Display Fan Speed...

Страница 9: ...ing Range About 7 meters When a signal is properly received by the air conditioner a beep be heard If no beep is heard press the Remote Control Unit button again Remote Control Unit Holder 1 2 3 PREPA...

Страница 10: ...thermostat setting button Press to lower the thermostat setting Thermostat setting range Cooling Drying 64 F to 88 F Fan 62 F to 88 F About three seconds later the entire display will reappear NOTE T...

Страница 11: ...an operation stops If the air emitted feels too cool raise the thermostat setting AUTO Depending on the room temperature at the time operation begins the operating mode will be switched automatically...

Страница 12: ...ON PROGRAM OFF ON OFF ON The indoor unit s TIMER Indicator lamp green Fig 3 6 will light Use the SET TEMP SET TIME button Fig 6 to adjust the desired OFF time or ON time Set the time while the time d...

Страница 13: ...t five seconds later the entire display will reappear To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Stop the Air Conditioner Dur...

Страница 14: ...mode operation for the first minute after beginning operation airflow will be horizontal 1 the air direction cannot be adjusted during this period Right Left Louvers Knob 1 2 3 4 5 6 7 Cooling Dry mod...

Страница 15: ...s operated with the controls on the Main Unit it will operate under the same mode as the AUTO mode selected on the Re mote Control Unit see page 8 The fan speed selected will be AUTO and the thermosta...

Страница 16: ...00 F The body may warp or change color More than 100 F ON OFF ON Cleaning the Indoor Unit Clean the indoor unit by wiping with a cloth dipped in cool or warm water then wipe with another soft clean dr...

Страница 17: ...take Grille Mounting shaft Bearing Knob Intake Grille 3 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth Raise the horizontal Intake Gr...

Страница 18: ...to accumulate on the Air Filter air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the Air Filters should be cleaned every two weeks Air filter ha...

Страница 19: ...he air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner res...

Страница 20: ...r if you notice burning smells or the TIMER Indicator Lamp Fig 3 6 flashes immediately stop operation disconnect the Power and consult authorized service personnel TROUBLE SHOOTING OPERATING TIPS WARN...

Страница 21: ...r than the Cooling and Dehumidifying and air circulation of rooms in ordinary dwellings Indoor temperature Outdoor temperature Indoor humidity Maximum Minimum Maximum Minimum Outdoor Temperature 68 F...

Страница 22: ...Sp 11 emplee la posici n 2 LONGITUD DE LOS TUBOS 25ft ESPECIFICACIONES INDOOR OUTDOOR 80 F DB 67 F WB 95 F DB 75 F WB MODEL INDOOR UNIT OUTDOOR UNIT TYPE POWER COOLING CAPACITY INPUT CURRENT REFRIGERA...

Страница 23: ...Espa ol Fran ais English Friedrich Air Conditioning Co 4200 North Pan Am Expressway Post Office Box 1540 San Antonio Texas 78218 Tel 210 357 4400 FAX 210 357 4480 Visit us at www friedrich com...

Отзывы: