3. Piping Diagrams
Heating
Heat Exchanger
Gas pipe connection port
F l a r e connection
Cooling
M
- - 3
- - 1
Sirocco Fan
- - 2
Liquid pipe connection port
Flare connection
LOC.
Description
PCB Connector
Th1
Thermistor for suction air temperature
CN_ROOM
Th2
Thermistor for evaporator inlet temperature
CN_PIPE
Th3
Thermistor for evaporator outlet temperature
CN_PIPEOUT
- 4 -
Содержание MD12Y3JM
Страница 6: ...5 Exploded View 6...