59
PB
FAULT
CODE
PROBLEM
CONTROL BOARD'S ACTION
1
Front Panel Button Stuck For More
Than 20 Seconds
Continue to monitor for "OPEN" (Unstuck) switch. Do not process
switch input. ENSURE FRONT COVER DOES NOT DEPRESS
BUTTONS
3
Indoor Temperature Sensor is Open
or Shorted
Set temp to 75°F in COOLING or 68°F in HEATING. Unit continues
to operate
4
Indoor Coil Temperature Sensor is
Open or Shorted
Control Board sets temp to a default of 40°F. Override sensor.
Unit continues to operate.
5
Outdoor Coil Temperature Sensor is
Open or Shorted
Sets temp to 20°F. Override sensor. Continue operation. Use Elec
Heat if available for HEATING. If not available use HEAT PUMP if
outdoor temp allows.
6
Outdoor Coil > (greater than) 175 F
Shut down for 5 min.
7
Indoor Coil < (less than) 30 F for 2
consecutive minutes
Turn compressor off. When coil temp reachs 45°F resume
operation after lockout time.
8
Unit Cycles > (grater than) 9 Times
per hour
Continue operation. Continue to monitor. Take no action. Log
Only.
9
Unit Cycles < (less than) 3 Times per
Hour
Continue operation. Continue to monitor. Take no action. Log
Only.
12
Discharge Air > (greater than) 185 F Shutdown electric heater until temp is 100°F. Resume
operation.
14
Discharge Air Temperature Sensor
is Open or Shorted
Override Sensor. Set temp to 75°F. Continue to monitor. Set
error code 14 ON.
16
Temperature Beyond Operating
Limits
Ambient temp < (less than) 0°F and ambient temp > (greater
than) 130°F. Set error code 16 ON. When cleared return unit to
normal.
22
Outdoor Coil Temperature < 30 F
for 2 consecutive Minutes
Unit will use electric heat to satisfy heating demands until temp
is greater than 45°F. Unit must be a Heat Pump with electric
heat.
23
Frost Protection.
Unit will run active defrost for up to 6 minutes when Heat Pump
run time is greater than 60 minutes and outdoor coil temp is 26 F
or less.
TROUBLESHOOTING
Diagnostic Codes
Figure 710 (Fault Codes)
Содержание Kuhl KCQ06A10A
Страница 68: ...68 PARTS CATALOG FIgure 901 5 10 15 20 25 35 A Detail A 30 40 45 50...
Страница 70: ...70 FIgure 902 PARTS CATALOG 5 10 15 20 35 45 40 50 55 25 30 65 60...
Страница 72: ...72 FIgure 903 PARTS CATALOG 90 95 60 JHUI 5 10 15 20 40 45 50 55 60 65 70 75 80 100 100 105...
Страница 77: ...77 THIS PAGE LEFT INTENTIONALLY BLANK...