Room Air Conditioner

Service and Parts

Manual

KP Line

 KP05 / KP06 (03/03)

KP05A10    KP06A10

Содержание KP05A10 KP06A10

Страница 1: ...Room Air Conditioner Service and Parts Manual KP Line KP05 KP06 03 03 KP05A10 KP06A10...

Страница 2: ...FAN 6 2 2 3 MOTOR 7 2 2 4 AIR GUIDE 7 2 3 ELECTRICAL PARTS 7 2 3 1 OVERLOAD PROTECTOR 7 2 3 2 COMPRESSOR 8 2 3 3 CAPACITOR 8 2 3 4 THERMOSTAT 8 2 3 5 ROTARY SWITCH 8 2 3 6 POWER CORD 9 2 4 REFRIGERAN...

Страница 3: ...THE SIMPLE INSTALLATION AND SERVICE BUILT IN ADJUSTABLE THERMOSTAT WASHABLE ONE TOUCH FILTER COMPACT SIZE 1 2 SPECIFICATIONS MODELS ITEMS COOLING CAPACITY BTU h 5 100 5 700 POWER SUPPLY Phase V Hz 1...

Страница 4: ...2 The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and sample the room air to determine if more cooling is needed TEMPERATURE SETTING 1 These buttons...

Страница 5: ...denser See Figure 3 4 Lift the cabinet from the unit 5 Re install by referring to the procedures above 2 1 3 CONTROL BOARD 1 Disconnect the unit from the power source 2 Remove the front grille Refer t...

Страница 6: ...ction 2 1 2 4 Remove the control board Refer to Section 2 1 3 5 Remove the air guide upper Refer to Section 2 2 1 6 Remove 2 screws that secure the base pan to condenser See Figure 7 7 Remove screw th...

Страница 7: ...2 1 2 4 Remove the control board Refer to Section 2 1 3 5 Remove the air guide upper Refer to Section 2 2 1 6 Remove the compressor turbo fan fan and shroud Refer to Section 2 2 2 7 Remove the motor R...

Страница 8: ...oss the capacitor terminals 4 Remove the screw which fastens the capacitor clamp 5 Remove all the leads of capacitor terminals 6 Re install the components by referring to the removal procedure above S...

Страница 9: ...uring the clip with cord to the control board 8 Pull the power cord 9 Re install by referring to procedures above 2 4 REFRIGERANT CYCLE 2 4 1 CONDENSER 1 Remove the cabinet Refer to Section 2 1 2 2 Di...

Страница 10: ...slowly with the two full turns counter clock wise This will keep oil from foaming and being drawn into the vacuum pump 6 3 Operate the vacuum pump for 20 to 30 min utes until 600 micron vacuum is obta...

Страница 11: ...proof seal leak detector tubing cutter hand tools to remove components and service valve B A B A B A COMPOUND GAUGE SEE INSETS BELOW CAPILLARY TUBE EVAPORATOR LOW PRESSURE SIDE COMPRESSOR CONDENSER HI...

Страница 12: ...llow a clear vertical opening of 13 from the bot tom of the sash to the window stool 2 If storm window presents interference fasten a 2 wide wood strip to the inner window sill across the full width o...

Страница 13: ...ackets behind the inner window sill with the short side of bracket as shown Use the 2 screws TYPE A provided b The bracket helps to hold unit securely in place Be sure to place bracket edge flush agai...

Страница 14: ...pening using 4 screws TYPE B to secure them as shown in Figure 31 5 INSTALL THE SASH SEAL AND SASH LOCK a Cut the sash seal TYPE E to the window width Stuff the sash seal between the glass and the win...

Страница 15: ...f potential safety hazards we strongly discourage the use of an extension cord However if you wish to use an extension cord use a CSA certified UL listed 3 wire grounding extension cord rated 15A 125V...

Страница 16: ...AIR MOTOR COMPRESSOR ROOM AIR HEAT LOAD CAPILLARY TUBE LIQUID REFRIGERANT LIQUID OUTLET VAPOR INLET COMPLETE LIQUID BOIL OFF POINT SUCTION LINE COOL LOW PRESSURE VAPOR LIQUID PRESSURE DROP DISCHARGE...

Страница 17: ...ce of inlet outlet air 55 59 F 13 15 C Replacement of unit if the unit is beyond repair Check outdoor coil heat exchanger and fan operation Check heat load increase Check cold air circulation for smoo...

Страница 18: ...ompressor capacitor Replacement of compressor Motor damaged Irregular motor insulation Irregular motor resistance Check of circuit breaker and fuse Gas leakage of feeler bulb of thermostat Check contr...

Страница 19: ...an blade hitting shroud or blower wheel hitting scroll Re align assembly Units using slinger ring condenser fans must have 0 22 0 25 inch clearance to the base If necessary shim up the bottom of the f...

Страница 20: ...diagram correct the connections Thermistor Check the TEMP control If not at the lowest number set TEMP control to this setting and restart the unit Check the continuity of the thermistor Replace the t...

Страница 21: ...crease causing the compressor to cycle Straighten the fins or replace the coil Capacitor Test the capacitor Wiring Check the terminals If loose repair or replace Refrigeration system Check the system...

Страница 22: ...5V T2A TRANS FORMER ZNR 4 3 RY COMP MAIN P W B ASM BK BK WH BK RD BL BL OLP RD MOTOR CAPACITOR F R S COMP C C H 3854A20022K WIRING DIAGRAM RY MID FUSE 1 POWER CORD ASSY 2H00677P 1 2 FAN MOTOR 4681A100...

Страница 23: ...349480 352390 1 149980 559011 346811 554030 W48602 130910 550140 554160 567502 352115 552102 352111 352113 35211A 135313 135303 152302 135312 132111 2 132111 1 159900 2 145200 159900 1 264110 238310...

Страница 24: ...SINGLE 4681A10002R 4681A10012M R 349480 ORIFICE 4948A10007A 67303405 R 352113 TUBE DISCHARGE 5210A21100A 5211A10129A 67302306 R 352115 TUBE ASSEMBLY EVAPORATOR IN 5211A10063C 67302005 R 35211A TUBE A...

Страница 25: ...25 MEMO...

Страница 26: ...26 MEMO...

Страница 27: ...st Office Box 1540 4200 N Pan Am Expressway San Antonio Texas 78295 1540 210 357 4400 FAX 210 357 4480 FRIEDRICH AIR CONDITIONING CO Visit our web site at www friedrich com P NO 3828A20207D Use Factor...