Max
.
length of connection pipe
Unit:
ft
3
1
1. Standard length of connection pipe
●
15ft, 22.5ft,24ft
4.
Additional refrigerant may be required when extending the line-set.
●
After the line-set has been extended 33ft past standard length of 25ft,
adding additional 5ml of refrigerant oil for each additional 16ft.
●
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
●
Basing on the length of standard pipe, add refrigerant according to the
Additional refrigerant charge amount = extended length of liquid line x
required additional amount per foot.
2.Min. length of connection pipe is
9Ft
.
3.Max. length of connection pipe.
Configuration of connection pipe
45
75
45
90
45
90
60
90
75
90
Cooling
capacity
Max
.
length
of connec-
tion pipe
Cooling
capacity
Max
.
length
of connec-
tion pipe
5000Btu/h
7000Btu/h
9000Btu/h
12000Btu/h
18000Btu/h
24000Btu/h
28000Btu/h
36000Btu/h
42000Btu/h
48000Btu/h
requirement as shown in the table. The additional refrigerant charging amount
per foot is different according to the diameter of liquid pipe. See the
following sheet.