20 – AUTO CHANGEOVER SET POINT OFFSET (DEAD BAND)
00-04
(01°F* default setting) Select the difference between the
guest-selected set point and the heat and the cool set point when the
thermostat is in the automatic temperature control mode.
This value plus the 1st stage differential defi ned in steps 02 and 04,
defi nes the temperature at which the thermostat would automatically
change heating/cooling modes.
This feature allows adjusting the deadband between the heat and the
cool set points in automatic changeover mode in order to avoid the
system from bouncing back and forth between heating and cooling
under normal operating conditions.
.