background image

Learn more about ductless

visit www.friedrich.com
to see an online video that explains the advantages 
of Friedrich ductless split systems

All models use

environmentally 

friendly R-410A 

refrigerant.

R-410A

Variable capacity advantages

Inverter Technology allows each system to 
adjust capacity and cooling output to provide 
only the amount of cooling needed at a given 
time. For example, an 18,000 BTU/h system 
will operate even more efficiently as a 

15,500 if that is all that’s needed.

Zero duct loss

The DOE reports that ducted systems lose 

an average of 25-40% in performance due to 
leaks, cracks or disconnections in ductwork. 
No ductwork means zero duct loss– ultra 
high efficiency delivers directly to the room. 

No dirty air ducts

Now there’s no need to clean dirty air ducts 
that can harbor dust, germs and allergens 
that are eventually blown into your home or 
office.

• Room additions/renovations

• Homes without ductwork

• Bedrooms and family rooms

• Garage workshops

• Sunrooms

• Guest quarters

• Wine cellars

Residential 

applications

Commercial 

applications

• Computer rooms/server 

rooms

• Restaurant kitchen and prep 

areas

• Offices in warehouse spaces

• Storage facilities

• Buildings where security 

concerns prevent the use of 
window units

• Internal areas without 

exterior wall access

Содержание C24YF

Страница 1: ...DUCTLESS SPLIT SYSTEMS SINGLE and MULTI ZONE WALL MOUNTED FLOOR CEILING UNIVERSAL CEILING CASSETTE and CEILING SUSPENDED...

Страница 2: ...d startup 3rd startup 1st shutdown 2nd shutdown Inverter Technology Standard Technology Standard Energy Usage Inverter reaches setpoint faster then adjusts capacity as required to maintain accurate te...

Страница 3: ...s lose an average of 25 40 in performance due to leaks cracks or disconnections in ductwork No ductwork means zero duct loss ultra high efficiency delivers directly to the room No dirty air ducts Now...

Страница 4: ...600 M30TYF 9300 9300 11800 30400 15 0 11000 11000 14000 36000 M33TYF 9400 11800 11800 33000 15 0 10700 13600 13600 37900 M36TYF1 9100 9100 17000 35200 15 0 9800 9800 18400 38000 M36TYF2 11700 11700 11...

Страница 5: ...or ceiling universal heat pump Universal system may be located low against the wall or on the ceiling Features Auto swing louvers up down left right Continuous Air Sweep Auto restart after power inter...

Страница 6: ...ht lbs 21 21 26 40 OUTDOOR UNIT W x H x D in 26 x 21 1 4 x 11 3 8 26 x 21 1 4 x 11 3 8 31 1 8 x 22 3 4 x 12 3 8 31 1 8 x 22 3 4 x 12 3 8 Net Weight lbs 55 71 88 97 Shipping Weight lbs 63 78 98 106 PER...

Страница 7: ...Net Weight lbs 21 ea 21 ea 21 21 21 ea 21 ea 21 21 ea Shipping Weight lbs 26 ea 26 ea 26 26 26 ea 26 ea 26 26 ea OUTDOOR UNIT W x H x D in 35 3 8 x 32 5 8 x 13 35 3 8 x 32 5 8 x 13 35 3 8 x 32 5 8 x...

Страница 8: ...5 8 5 8 Factory Precharge ft 50 50 50 Max Line Length ft 165 165 165 Max Height Difference ft 66 98 66 DIMENSIONS WEIGHT INDOOR UNIT W x H x D in 39 x 7 7 8 x 25 3 4 65 3 8 x 9 1 2 x 27 1 2 32 5 8 x...

Отзывы: