- 2 -
Only for training and service purposes
1. Specification
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7℃(80℉) DB / 19.4℃(67℉) WB
Outdoor 35℃(95℉) DB / 23.9℃(75℉) WB
- Heating Temperature : Indoor 21.1℃(70℉) DB / 15.6℃(60℉) WB
Outdoor 8.33℃(47℉) DB / 6.11℃(43℉) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation.
Model Name
AUUW36GD2
[MR36UY3J]
Power Supply
V , Ø , Hz
208-230 / 1 / 60
Starting Current
Cooling
Max.
A
-
Heating
Max.
A
-
Wiring Connections
Power Supply Cable (included Earth)
No. x mm
2
(AWG)
3C x 5.0 (10)
Casing Color
-
Warm Gray
Dimensions
W x H x D
mm
W x H x D
inch
Net Weight
kg (lbs)
Compressor
Type
-
Twin Rotary
Model
Model x No.
Motor type
-
Motor Output
W x No.
Refrigerant
Type
-
Precharged Amount
g (oz)
Chargeless-Pipe Length
m (ft)
Additional Charging Volume
g/m (oz/ft)
Control
-
Electronic Expansion Valve
Refrigerant Oil
Type
-
Charged volume
cc x No.
Heat Exchanger
(Row x Column x Fins per inch) x No.
-
Fan
Type
-
Air Flow Rate
m
3
/min(ft
3
/min) x No.
Fan Motor
Type
Output
W x No.
Sound Pressure Level
Cooling
Rated
dB(A)
Heating
Rated
dB(A)
Sound Power Level
Rated
dB(A)
Piping Connections
Liquid
Outer Dia.
mm(inch)
Gas
Outer Dia.
mm(inch)
Piping Length
Max.
m (ft)
Maximum Height Difference
Outdoor Unit ~ Indoor
Unit
Max.
m (ft)
30 (98.4)
Operation Range (Outdoor Temperature)
Cooling
Min. ~ Max.
℃ DB (℉ DB)
-15 (5.0) ~ 48 (118.4)
Heating
Min. ~ Max.
℃ WB (℉ WB)
-18 (-0.4) ~ 18 (64.4)
950 × 1,380 × 330
37-13/32 × 54-11/32 × 13
92.0 (202.8)
GPT442MBA x 1
BLDC
4,000 x 1
R410A
3,400 (119.9)
7.5 (24.6)
40 (0.43)
FVC68D
1,300 x 1
(2 x 32 x 14) x 2
Propeller
55(1942)×2
BLDC
124.0 x 2
52
54
67
Ø 9.52 (3/8)
Ø 15.88 (5/8)
75 (246.1)
Indoor Unit
ABNH36GRLA2
[MD36Y3J]
ATNH36GMLE2
[MC36Y3J]
Capacity
Cooling
Min. ~ Rated ~ Max.
kW
4.7~10.5~12.1
4.10 ~ 10.5 ~ 12.3
Min. ~ Rated ~ Max.
Btu/h
16,200 ~ 36,000 ~ 41,400
14,000 ~ 36,000 ~ 42,000
Heating
Min. ~ Rated ~ Max.
kW
5.2 ~ 11.7 ~ 13.4
4.25 ~ 11.7 ~ 13.1
Min. ~ Rated ~ Max.
Btu/h
18,000 ~ 40,000 ~ 46,000
14,500 ~ 40,000 ~ 45,000
Power Input
Cooling
Rated
kW
2.97
2.97
Heating
Rated
kW
3.36
3.2
EER / COP
Btu/h·W
12.1/-
13.5 / -
SEER / HSPF
Btu/h·W
17.6 / 9.2
19.0 / 9.5
Содержание AUUW36GD2
Страница 6: ...P No MFL67690608...