HEATING LOAD FORM
FRIEDRICH ROOM UNIT HEAT PUMPS
BTU/HR PER
WALLS:
(Linear Feet
°F. TEMP. DIFFERENCE
2" Insulation
Lin. Ft. x 1.6
Average
Lin. Ft. x 2.6
WINDOWS & DOORS
(Area, sq. ft.
Single Glass:
Sq. Ft. x 1.13
Double Glass:
Sq. Ft. x 0.61
INFILTRATION - WINDOWS & DOORS: AVG.
Lin. Ft. x 1.0
Loose
Lin. Ft. x 2.0
CEILING
: (Area, Sq. Ft.)
Insulated (6")
Sq. Ft. x 0.07
Insulated (2")
Sq. Ft. x 0.10
Built-up Roof (2" insulated
Sq. Ft. x 0.10
Built-up Roof (1/2" insulated)
Sq. Ft. x 0.20
No Insulation
Sq. Ft. x 0.33
FLOOR:
(Area, Sq. Ft.)
Above Vented Crawl space
Insulated (1:)
Sq. Ft. x 0.20
Un-insulated
Sq. Ft. x 0.50
* Slab on Ground
Lin. Ft. x 1.70
1" Perimeter insulation
Lin. Ft. x 1.00
* Based on Linear Feet of outside wall
TOTAL HEAT LOSS PER °F BTU/HR/°F
Multiply total BTU/HR/°F X 30 and plot on the graph below at 40°F. Draw a straight line from the
70 base point thru the point plotted at 40°F. The intersection of this heat loss line with the unit
capacity line represents the winter design heating load.
Содержание 2000 TwinTemp EK12J33A-1
Страница 36: ...Page 36 WIRING DIAGRAM FOR MODEL YS09J10 1...
Страница 37: ...Page 37 WIRING DIAGRAM FOR MODELS YS13J33 YM18J34A YL24J35A...
Страница 38: ...Page 38 WIRING DIAGRAM FOR MODELS ES12J33 ES15J33A EM18J34A EL24J35 EL33J35 EK12J33A EK18J34A 2 EK18J34A 3...
Страница 39: ...Page 39 YS YM YL SERIES CHASSIS PARTS...
Страница 40: ...Page 40 YS YM YL SERIES CABINET MOUNTING PARTS...
Страница 46: ...Page 46 ES EM SERIES CHASSIS PARTS...
Страница 47: ...Page 47 ES EM SERIES CABINET MOUNTING PARTS...
Страница 51: ...Page 51 EL SERIES CHASSIS PARTS...
Страница 52: ...Page 52 EL SERIES CABINET MOUNTING PARTS...
Страница 56: ...Page 56 EK SERIES CHASSIS PARTS...
Страница 57: ...Page 57 EK SERIES CABINET MOUNTING PARTS...