3. To use with a transformer powered chime circuit 

Some installations may require this method of connection, for example, to add 
a wire-free door chime to extend the use of a wired chime.
Connect the converter across the existing door chime, or use it in place 
of the existing wired chime. Use terminals 1 and 3.

230v

~

8v

~

1 2 3

230v

~

8v

~

1 2 3

Or

Alternative Connection

Fig. 3

Transformer

4. Installation.

For wire exit, remove the breakout area (B) at the bottom left of the base (or inside
the cover). Mount the converter vertically and clip the battery into its holder, + side
facing out (Fig. 4). Then replace the cover, clipping in the top first, then pressing
down so that the bottom clips in.

5. Test the converter

The unit operates when the door push is pressed,
but only as the push is released. 
The indicator (A) on the front of the unit lights
when the unit operates.