AD Corinte W - ADCS

6

100

126

1700/2200

1670/2170

75

Cu ø22

Cu ø22

Min 180 mm

50

75

376

Min 180 mm

Fig 6a

Fig 6b

Left connection

Right connection

Wall

Содержание Thermozone AD Corinte W ADCS17WH

Страница 1: ...AD Corinte W ADCS 16 SE 46 IT 28 RU 22 NO 25 FR 34 NL 37 ES 43 FI 19 GB 40 PL 31 DE 49 DK ...

Страница 2: ...AD Corinte W ADCS 2 M8 M8 Cu ø22 VL A VL B VR A VR B Min 180 225 125 72 116 Min 180 225 125 72 116 Doorway Wall Wall Top Bottom seen from above Top Bottom seen from above Fig 1 ...

Страница 3: ...AD Corinte W ADCS 3 1 2 80 60 1 2 60 80 3 Ø22 Cu PH2 1 4 Fig 2 Fig 3 Ø22 Cu 2200 2450 500 350 ...

Страница 4: ...AD Corinte W ADCS 4 1 2 3 4 5 6 7 8 9 10 A B C Fig 4 ...

Страница 5: ...AD Corinte W ADCS 5 Fig 5 ...

Страница 6: ...AD Corinte W ADCS 6 100 126 1700 2200 1670 2170 75 Cu ø22 Cu ø22 Min 180 mm 50 75 376 Min 180 mm Fig 6a Fig 6b Left connection Right connection Wall ...

Страница 7: ...AD Corinte W ADCS 7 Fig 6c Fig 6d 360 243 Ø22 Ø10 15 5 10 Fig 7 80 35 ø12 180 35 25 40 ...

Страница 8: ... bovenkant 2 opcio nes de sujeción a la parte superior 2 opcje montażu w części górnej 2 vaihtoehtoista kiinnitystapaa 2 alternative per il montaggio sulla parte superiore 2 alternativer til fastgørelse foroven 2 Ø8 för stagning i luftridån Ø8 for montering på luftporten Ø8 pour fixation du rideau d air Для крепления к завесе Ø 8 zur Befestigung am Luftschleier Ø8 voor bevestiging aan het lucht go...

Страница 9: ...AD Corinte W ADCS 9 ADCS SIRe Fig 8 SIRe ...

Страница 10: ...IReAC SIReAA SIReRTX SIReUR SIReWTA SIReCC SIReCJ4 SIReCJ6 VKF SDM24 ST23024 SD230 BPV10 VKF VLSP VLP Type RSK nr SE NRF nr NO Connection VLSP15LF 670 45 35 DN15 VLSP15NF 670 45 36 850 26 36 DN15 VLSP20 670 45 37 850 26 37 DN20 VLSP25 670 45 38 850 26 38 DN25 VLSP32 670 45 39 850 26 39 DN32 VLP15LF 670 45 30 673 09 47 DN15 VLP15NF 670 45 31 850 26 31 DN15 VLP20 670 45 32 850 26 32 DN20 VLP25 670 4...

Страница 11: ...ring diagram ADCS W 230V SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L N ...

Страница 12: ...Unit ID ACTUATOR SUPPLY N L N L PE L 230V C2 X5 C1 X4 ROOM X3 Pot Unit ID ACTUATOR SUPPLY N L N L PE L 230V SIReCC6XX max 50 m SIReB1 B2 B1EC SIReB1 B2 B1EC SIReB1 B2 B1EC SIReCC6XX max 50 m SIReCC6XX max 50 m SIReUB1 SIReRTX optional SD230 SD230 SD230 L 1 5m L 2m Wiring diagrams for SIReAC Competent and SIReAA Advanced see manuals for SIRe ...

Страница 13: ...00 13 6 27 0 04 0 3 38 2 64 6 0 31 10 3 Supply water temperature 90 C Room temperature 18 C Outlet air temperature 35 C 1 Water temperature 90 70 C Room temperature 18 C Type Fan position Airflow m3 h Output kW Return water temp C Water flow l s Pressure drop kPA Output 2 kW Outlet air temp C Water flow l s Pressure drop kPA ADCS17WH max 3200 18 1 39 0 09 0 8 32 47 3 0 39 11 7 min 1500 8 7 35 0 04...

Страница 14: ... 6 min 2400 13 7 27 0 08 0 9 27 2 51 2 0 33 10 6 Supply water temperature 60 C Room temperature 18 C Outlet air temperature 35 C 1 Water temperature 60 40 C Room temperature 18 C Type Fan position Airflow m3 h Output kW Return water temp C Water flow l s Pressure drop kPA Output 2 kW Outlet air temp C Water flow l s Pressure drop kPA ADCS17WL max 3200 18 7 37 0 20 3 4 20 4 36 6 0 25 4 8 min 1500 8...

Страница 15: ...area 200 m At lowest highest airflow 5 t temperature rise of passing air at maximum heat output and lowest highest airflow 6 Applicable at water temperature 80 60 C air temperature in 18 C 7 Applicable at water temperature 60 40 C air temperature in 18 C Protection class IP20 CE compliant Type Output 6 kW Airflow 3 m3 h t 5 6 C Water volume l Sound level 4 dB A Motor W Voltage motor V Amperage mot...

Страница 16: ...n see Figure 4 1 Remove the two screws that secure the intake grille A and remove this 2 Undo the screws holding the front panel C on the exhuast side B 3 Undo the two screws in the front panel and remove it 4 Place the edging in level on the floor and secure it through the countersunk holes see Fig 7 Place the air curtain on the edging 5 A flat bar is included for securing the air curtain Fixate ...

Страница 17: ...e connection from below can be done the following way Flexible hoses may be drawn through drilled holes in the floor and connected to the air curtain pipes The flexible hoses are connected to the system beneath the floor Note At connection from below avoid placing hoses or pipes so that they obstruct the air flow to the fans If necessary secure them to avoid vibrations and prevent them from being ...

Страница 18: ... undertake cleaning at least twice a year Safety Ensure that the area around the intake and exhaust grille is kept free from material wich could prevent the air to flow through the unit During operation the surfaces of the unit are hot This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowle...

Страница 19: ...8033 2017 02 28 CH LE Main office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se ...