Thermocassette HP

9

GB  

pole switch in accordance with existing 
regulations (not applicable to versions with 
a cord and plug).

3.  Measure, drill and screw the two loose 

brackets to the ceiling. Do not tighten the 
screws yet. It is important that the holes 
come at right angles, cross measure. (fig. 
3A)

4.  Hook the panel brackets to the ones on the 

ceiling (only the side nearest to the cable 
gland). Allow panel to hang vertical. (fig. 
3B)

5.  Connect the panel.
6.  Swing up the panel, and adjust the lateral  

position of the ceiling mounted brackets. 
(fig. 3C)

7.  Swing down the panel and tighten the 

screws in the ceiling. (fig. 3D)

8.  Swing up the panel again and hook the 

panel bracket ends in the ceiling brackets. 
NOTE! Make sure that the brackets do not 
become unhooked at the other end.

9.  Secure the panel with a screw (enclosed 

on  delivery) at each hanging point. (fig. 
3E)

10.The second last page in this mounting 

instruction is to be filled out and fixed 
adjacent to the distribution board and it 
has to contain (drawing) the locations of 
the heating units.

Replacement of cable for HP305 or HP605

1.  Because of limitations in the IP55 category 

the cable cannot be changed.

2.  If the cable is damaged the unit has to be 

scrapped.

Safety

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they 
have been given supervision or instruction 
concerning use of the appliance by a person 
responsible for their safety. Children should 
be supervised to ensure that they do not play 
with the appliance.

Содержание Thermocassette HP Series

Страница 1: ...Thermocassette HP 6 14 10 12 8 GB FR NO DE SE 16 FI 18 RU ...

Страница 2: ...te HP 2 HP605 HP305 False ceiling HP300 600 Min distance mm Ceiling 80 Wall long side of the unit 50 Wall short side of the unit 50 Obstacle 500 Floor 1800 Fig 1 Minimum mounting distance Minimum mounting distance ...

Страница 3: ...Thermocassette HP 3 Mounting Min 1 5 mm Max 2100W Fig 3 A B C D E Fig 1 Fig 2 ...

Страница 4: ... IP55 jet proof design CE compliant Complies with the requirements for flammable areas according to SEMKO 111FF 1 SE Effekt GB Output NO Effekt FR Puissance DE Heizleistung RU Мощность FI Lämmitysteho 2 SE Spänning GB Voltage NO Spenning FR Tension DE Spannung RU Напряжение FI Jännite 3 SE Ström GB Amperage NO Strøm FR Intensité DE Stromstärke RU Ток FI Virta 4 SE Maximal yttemperatur GB Max surfa...

Страница 5: ...ring diagrams HP L N HP K 1 2 U 3 4 U K G G L N 230V ERP HP L N HP L N HP L N HP L N HP P 230V N Thermostat Control by thermostat Output control Internal wiring diagram ERP T10S TK10S 230V HP300 HP600 HP300 HP600 L N HP 230V ...

Страница 6: ...he cable section has to be at least 1 5 mm2 Units with cable and plug can be inter connected using the sockets on the back of the heaters The maximum power in inter connection is 2100 W If the units are to be extra insulated then this insulation must not exceed a value of R 5 m2 K W Mounting Integrated in ceiling put in exposed grid See fig 2 1 Lateral distance to wall shall be at least 50 mm 2 Th...

Страница 7: ...ts NOTE Make sure that the brackets do not become unhooked at the other end 9 Secure the panel with a screw enclosed on delivery at each hanging point fig 3E 10 The second last page in this mounting instruction is to be filled out and fixed adjacent to the distribution board and it has to contain drawing the locations of the heating units Replacement of cable for HP305 or HP605 1 Because of limita...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...d OBS do not restrict the thermal emission of the heated ceiling do not affix materials other than those recommended do not insert nails or screws HP300 300W 220 240V HP305 300W 220 240V HP600 600W 220 240V HP605 600W 220 240V Drawing of the installation ...

Страница 12: ...100601 HH Main office Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se ...

Отзывы: