Страница 1: ...PLS Competent Quick guide PLSAC GB...

Страница 2: ...SUPPLY N L N L PE L 230V C2 X5 C1 X4 ROOM X3 Pot Unit ID ACTUATOR SUPPLY N L N L PE L 230V C NC SIReDC SIReRTX optional SIReC1X SIReCC6XX max 10 m SIReB1 B2 B1EC SIReB1 B2 B1EC SIReB1 B2 B1EC SIReCC6X...

Страница 3: ...t Unit ID ACTUATOR SUPPLY N L N L PE L 230V C2 X5 C1 X4 ROOM X3 Pot Unit ID ACTUATOR SUPPLY N L N L PE L 230V C NC SIReUA1 SIReC1X SIReDC SIReRTX optional SIReC1X SIReCC6XX max 10 m SIReB1 B2 B1EC SIR...

Страница 4: ...4 PLS Competent 1 SE GB Wiring diagram Advanced SIRe B1 B2 B1EC 2 PLSB1 B2...

Страница 5: ...5 PLS Competent OK OK 4 3a Wiring diagram Advanced 8 7 0 1 2 3 4 5 6 9 3b 1 0 OK...

Страница 6: ...6 PLS Competent 5 Svenska Polski Norsk English English Deutsch e tina Fran ais Sloven ina Italiano T rk e Espa ol Deutsch Nederlands Rom n Suomi Magyar Dansk UA1Y UA1Z...

Страница 7: ...ch is set in the ID selector of the PLSB1 B2 Each unit should have a unique ID on its PLSB1 B2 card 3 Power up all units 4 The start up wizard runs and basic settings are made The system check identif...

Страница 8: ...PLSUA1 CC PLSRTX CJ4 CJ6 CC Type Description HxWxD L m PLSRTX External room temperature sensor 70x33x23 10 CJ4 Joint piece for two pcs RJ11 4 4 CJ6 Joint piece for two pcs RJ12 6 6 CC603 Modular cabl...

Страница 9: ...TAC15NF AV15 DN15 VKF20 TAC20 AV20 DN20 VKF25 TAC25 AV25 DN25 VKF32 TAC32 AV32 DN32 SD230 Actuator on off 230V BPV10 By pass valve DN10 VOT15 Three way valve and actuator on off DN15 VOT20 Three way v...

Страница 10: ...t OFF Fan speed step Back Forward Confirm Alarm Red led Run signal Green led Heating step Week program Day Week program Night Week program Out of operation Overview Control unit PLSUA1 Air curtains 19...

Страница 11: ...ntrol and over run functions Main menu Reset alarm Note Before resetting check that the fault is rectified and there is nothing to prevent the unit from being recommissioned Press and select reset ala...

Страница 12: ...larm has been reached External alarm input terminal 9 10 on PLSC1X has been activated External alarm Check that nothing is obstructing the unit s air intake and exhaust Check that nothing is obstructi...

Страница 13: ...gram error No program Try to reset the alarm Disconnect power set ID 0 and reconnect power to test the B1 B2 pc board result If the unit is running act as if it was an E1 Communication error If it is...

Страница 14: ...the system Make sure all units are from the same release contact technical support Internal sensor Error Room sensor error Room sensor error Communication error Cables are not original Logging tool or...

Страница 15: ...rnal filter guard On Always active Setback temperature External voltfree dry contact Close to activate night temperature Always active Door contact Mandatory External voltfree dry contact DC included...

Страница 16: ...Art no 212001 2016 06 29 HH CH Technical Support tel 46 313368600...