commencing any electrical work!

  Risk of fire! 
• The device is secured and held in the ceiling 

cut-out by means of four retaining clamps. 
The edge of the ceiling cut-out must have a 
sufficient load-bearing capacity for securing 
the radiant heater.

• The ceiling cut-out must have the 

dimensions 305 to 310 mm x 510 to 580 
mm.

• When installing the device, no supporting 

elements such as joists, rafters or roof 
battens should be damaged.

• Under no circumstances should the cavity 

above the radiant heater be filled with 
insulating material or other materials.

• Sufficient air exchange for heat dissipation 

must be ensured in the cavity above the 
radiant heater.

• The device is equipped with a mains lead 

fitted with a grounding type plug without a 
switch. The device must be switched on and 
off by means of a locally installed switch.

  Only commission the device after it has 

been fully installed.

COMMISSIONING

• After switching on the device when 

commissioning it for the first time as well 
as after a lengthy period of non-use, it is 
possible that odors may be emitted for a 
short while. 

CLEANING

• First disconnect the device from the mains. 
• Once cooled down, it is possible to wipe 

down the frame dry. 

• Do not touch quartz bars with fingers, as 

doing so can leave marks and cause them to 
fail. 

• The reflector should be cleaned at regular 

intervals from outside with a paint brush. 

• Do not use abrasive or caustic detergents! 
• Never immerse the device in water! Risk of 

fatal injury! 

CUSTOMER SERVICE

• Only authorized professionals are permitted 

to perform repairs to the device! 

Important! Unprofessional tampering 

invalidates all warranty entitlement. 

• Improper repairs can result in considerable 

risks for the user! 

TECHNICAL DATA

Color: White or silver
Casing: Sheet steel, varnished
Cord length: 2.9 m with grounding type plug
Switching on/off: Via separate light switch to 
be installed (locally) by the electrician
Application: Indoors

Technical Data

Connection/fuse: 230/240 Volt (50/60 Hz) 
with 16 Amp B or  C (= slow-blowing fuse)
Output: 1500 Watt / 2000 Watt
Infrared tube: HANA ‘Gold Tube’
Guaranteed service life: 5000 hours (approx. 
10-15 years with average use)
Type of protection: IP 20

Dimensions (W x D x H): 600 mm x 325 mm x 
110 mm
Weight: 4.55 kg

Installation depth: min. 450 mm
Cut-out length/width: 305 to 310mm x 510 to 
580 mm
Ceiling panel/panel thickness: max. 15 mm