Application area

The fan heater is approved for rooms with 
high surrounding temperature, up to 70 °C, for 
example test rooms for electronic equipment. For 
both fixed installation and portable use.

The fan heater should be installed for easy 

maintenance and inspection. For portable use, 

mount a suitable terminal with approperiate 

protection class. The fan heater is tested and 

aproved according to the EMC- and SEMKO 

regulations and is CE compliant.

Protection class: IP44

The casing and heating rods are made of 

stainless steel SS2320. 

Operation

The fan is running constantly unless the output 
selector is set in 0 position. The heat output is 
controlled by the built-in thermostat (0 – +70 °C) 
or with an external thermostat ELRT.

The on/off mode, and half or full heat output can 

be controlled with the output selector on the unit. 

External thermostat is ordered separately.

  

Off

 

Only fan

 

Fan + half output

 

Fan + full output

Mounting

Elektra H can be mounted permanently on the 
wall or be used as a portable fan heater. 

Wall mounting

The fan heater must not be placed directly under 
a wall outlet. Remove the plastic feet on the 
brackets.

1.  Drill four holes in the wall with a c-c distance  

  according to fig. 2 on page 2. Fit the screws in  

  the upper two holes. 

2.  Attach the brackets on to the fan heater   

  according to fig. 3 on page 3 with three screws  

  on each side.

3.  Hang the heater by using the keyholes in the   

bracket and lock with the two lower screws.
Note! The minimum distances according to fig. 1 
on page 2.

Portable use

Mount the enclosed brackets according fig. 4 on 
page 3. 

Electrical installation

The electrical installation should be carried out 
by a qualified electrician in conformity with 
prevailing regulations. The appliance should be 
preceded by an all-pole switch with at least 3 mm 
breaking gap. 

Use the knock-outs on the back of the appliance 

for installation of external thermostat (ELRT). 

Cable-glands used must guarantee the protection 

class requirements.

Overheating 

The heater is equipped with an overheat 
protection with manual reset. If it is released due 
to overheating, reset as follows:

•  Disconnect the power with the fully isolated  

 switch.

•  Investigate the matter and repair the fault.

•  Reset cut-out by pressing the red button until  

  a click is heard. The reset button is located  

  on the back side of the unit.

•  Restart the unit and check the operation. 

  If the fault continues, please contact a    

  qualified technician.

Safety cut-out 

If the installation is protected by means of a 
safety cut-out, which trips when the appliance is 
connected to RCD, this may be due to moisture 
in the heating element. When an appliance 
containing a heating element, has not been 
used for a long period and is stored in a damp 
environment, moisture can enter the element. 
This should not be seen as a fault, but is simply 
rectified by connecting the appliance to the 
mains supply via a socket without a safety cut-
out, so that the moisture can be driven out of the 
element. 

The drying time can vary from a few hours to 

a few days. As a preventive measure the heater 

should occasionally be run for a short time when 

it is not being used for an extended period of time.

Maintenance

Note! Opening the heater cover should only be 
done by a qualified installer.

Always disconnect the power supply before 
opening the cover or doing any maintenance 
work.
The appliance should be cleaned regularly both 
inside and outside, to prevent overheating and 
risk of fire but also to guarantee long life of the 
heater.

Содержание Elektra H Sereis

Страница 1: ...Elektra H 7 9 GB 11 NO 17 DE 19 PL 13 FR 21 FI 15 RU SE 27 IT 25 ES 23 NL...

Страница 2: ...Elektra H 2 ELH623 ELH633 ELH933 min 500 mm min 300 mm min 300 mm 445 375 430 Fig 1...

Страница 3: ...Elektra H 3 405 465 390 545 3 10 405 525 425 485 9 16 50 300 240 445 336 9 28 c c 350 274 Fig 3 Fig 4 Fig 2...

Страница 4: ...Output steps kW Voltage V Amperage A Airflow m3 h Sound level 3 dB A t 2 C Weight kg ELH623 6 0 3 6 230V3 7 8 15 4 1000 551 24 20 ELH633 6 0 3 6 400V3N 4 5 8 9 1000 551 24 20 ELH933 9 0 4 5 9 400V3N...

Страница 5: ...Elektra H 5 1 Element 2 Fan motor 3 Switch 4 Thermostat 5 Overheat protection Elektra H ELRT 230V3 Elektra H 230V3 ELH623 Remove...

Страница 6: ...Elektra H 6 Elektra H ELRT 400V3 Elektra H 400V3 ELH633 ELH933 Remove 1 Element 2 Fan motor 3 Switch 4 Thermostat 5 Overheat protection...

Страница 7: ...on should be carried out by a qualified electrician in conformity with prevailing regulations The appliance should be preceded by an all pole switch with at least 3 mm breaking gap Use the knock outs...

Страница 8: ...etc should only be done by a qualified installer This fan heater must not be used next to a shower bath or swimming pool Place the fan heater away from flammable materials Ensure that the area around...

Страница 9: ...ain office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se 20141103 HH...

Отзывы: