1

Retaining screw

2

Wedging block

3

Wedging block

Cleaning

Switch off the unit and remove the plug from 

the socket before cleaning. 

1. Clean the surface of AC with a wet soft 

cloth. Don't use chemicals, such as benzene, 

alcohol, gasoline, etc.; otherwise, the surface 

will be damaged or even the whole AC will be 

damaged.

2. If the filter screen is clogged with dust, and 

the effectiveness of the AC is reduced, be sure 

to clean the filter screen once every two weeks.

2.1 Clean the upper filter screen frame

• 

Clasp the wedging block of the EVA filter 

screen frame with hands. Force down from 

the outside to remove the EVA filter screen 

frame. Unscrew four screws fixing the 

EVA filter  screen and the rear housing to 

remove the EVA filter screen (as shown in 

the below figure).

• 

Put the EVA filter screen into warm water 

with neutral detergent (about 40 °C /104 °F) 

and dry it in the shade after rinsing clean.

2.2 Clean the lower filter screen frame

• 

Hold the handle of the CON filter screen 

frame, and pull it outward gently to remove 

it.

• 

Put the CON filter screen into 

warm water with neutral detergent  

(about 40  °C /104 °F)  and dry it in the 

shade after rinsing clean.

Storage

•  Unscrew the drainage cover, unplug the 

water plug, and discharge the water in the 

water pan into other water containers or 

directly tilt the unit to discharge the water 

into other containers.

•  Tum on the AC, adjust it to low-fan 

ventilation mode, and maintain this state 

until the drainage pipe becomes dry, so as 

to keep the inside of the unit in a dry state 

and prevent it from mildewing.

•  Tum off the AC, unplug the power plug, and 

wrap the power cord around the wrapping 

hooks; install the water plug and the 

drainage cover.

•  Remove the vent hose and keep it properly.

•  Cover the AC with a plastic bag. Store in 

a dry place, keep it out of the reach of 

children, and take dust control measures.

•  Remove batteries of the remote control and 

keep them properly.

Note: ensure that the unit is placed in a dry 

place and keep all AC components properly.

Содержание Climobile

Страница 1: ...Climobile 2 EN 11 SE Original instructions 20 DE ...

Страница 2: ...ct into the air inlet and outlet of the AC Keep the air inlet and outlet free from obstructions When drainage pipes are installed ensure that the drainage pipes are properly connected and are not distorted or bended Use a water trap if the hose is connected to the drainage system While adjusting the upper and lower wind guide strips of the air outlet pluck it with hands gently to avoid damaging wi...

Страница 3: ...ion and ventilation function Automatic swing hatch in the outlet has automatic air swing function and the outlet can be covered when the AC is turned off to prevent dust from entering the unit LCD screen and LCD remote control to facilitate operation The remote control can be placed on the back of the unit Handles on both sides The hooks to wrap the power cord on the back facilitates users to hang...

Страница 4: ...ious components of it 1 3 Install the unit 1 Move the unit with installed vent hose and fittings before the window and the distance between the unit and walls or other objects shall be least 50 cm as shown in fig 4 2 Elongate the vent hose and snap the flat end of the vent hose joints into the elliptical hole of the window cover plate as shown in fig 5 and fig 6 Notes The flat end of the vent hose...

Страница 5: ...as follows While setting temperature press up key or down key to select the required temperature not available in ventilation or dehumidification mode Simultaneously press both keys to switch between Celsius C and Fahrenheit F Fan In cooling heating and ventilation mode press the key to select high medium or low fan speed operation In dehumidification mode low fan speed operation is automatically ...

Страница 6: ...ration 3 2 Overflow Protection Function When water in the water pan exceeds the warning level the AC will automatically sound an alarm and the LDC screen will show FL At this point you need to move the drainage pipe connecting the AC or the water outlet to a sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter After the water is emptied the A...

Страница 7: ...n be tilted slightly backwards If the container cannot hold all the water before it is full block the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet 4 When the water is emptied insert the water plug and tighten the drainage cover Notes Restart the AC after the water plug and drainage cover are installed otherwise condensate water will ...

Страница 8: ...ng clean 2 2 Clean the lower filter screen frame Hold the handle of the CON filter screen frame and pull it outward gently to remove it Put the CON filter screen into warm water with neutral detergent about 40 C 104 F and dry it in the shade after rinsing clean Storage Unscrew the drainage cover unplug the water plug and discharge the water in the water pan into other water containers or directly ...

Страница 9: ... of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air does not pass freely through the unit Make sure the air inlet and outlet are not obstructed Big noise The unit is not placed on a flat surface Put the unit on a flat and hard surface to reduce noise The compressor does not work Overheat protection is activated Wait fo...

Страница 10: ...ment and are therefore recyclable Handling of product at end of working life This product may contain substances necessary for the functionality of the product but potentially dangerous for the environment The product should not be disposed of mixed with general household waste but delivered to a designated collection point for environmental recycling Please contact the local authority for further...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ... 23 HH CH Main office Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net ...

Отзывы: