Service, repairs and maintenance

For all service, repair and maintenance first 
carry out the following:
1. Disconnect the power supply. Note! Units 

with electrical heaters can be supplied from 
more than one connection.

2. The front panel/service hatch is opened by 

slackening off the screws on the unit.

Maintenance

Since fan motors and other components are 
maintenance free, no maintenance other 
than regular cleaning is necessary. The 
frequency of cleaning can vary depending on 
local conditions, but undertake cleaning at 
least twice a year. Inlet and exhaust grilles, 
impeller and elements can be vacuum cleaned 
or wiped using a dry cloth. Use a brush when 
vacuuming to prevent damaging sensitive 
parts. Avoid the use of strong alkaline or 
acidic cleaning agents.

Overheating

 

The motors in all the air curtain units 
have a built-in thermal safety cut-out to 
protect against overheating. This will reset 
automatically once the motor has cooled.

Fan replacement

1. Determine which of the fans is not 
functioning.
2. Disconnect the cables to the relevant fan.
3. Remove the screws securing the fan and lift 
the fan out.
4. Install the new fan in reverse order to the 
above.

Changing the water coil (AGI  W)

1. Turn of the units water supply.
2. Disconnect the cables to the water coil.
3. Remove the mounting screws securing the 

water coil in the unit and lift the water coil 
out.

4 Install the new water coil in reverse order to 

the above.

Draining the water coil (AGI W)

The drain valve is on the underside of the coil 
on the connector side. It can be accessed via 
the service hatch.

Troubleshooting

If the fans are not working or not blowing 
enough, check the following:

• 

Operating power supply to the unit; 
check fuses, circuit-breaker, time 
switch/thermostat (if any) that starts 
and stops the unit.

• 

That the speed regulator is correctly 
set.

• 

That any position limit switch is 
working.

• 

That the thermal safety cut-out for the 
motors has not been deployed.

• 

That the intake grille/filter is not dirty.

If there is no heat, check the following:

• 

Check that the settings for the 
thermostat, switches etc. are set so that 
the unit can produce heat. 

For units with water coil, also check the 
following:

• 

That the water coil is bled.

• 

That there is a sufficient water flow. 

• 

That the incoming water is sufficiently 
hot.

If the error cannot be fixed, please contact a 
qualified service technician.

Safety

•  Keep the areas around the air intake 

and exhaust grilles free from possible 
obstructions!

•  During operation the surfaces of the unit 

are hot!

•  The unit must not be fully or partially 

covered with clothing, or similar 
materials, as overheating can result in a 
fire risk! 

•  This appliance is not intended for use by 

persons (including children) with reduced 
physical or mental capabilities, or lack 
of experience and knowledge, unless they 
have been given supervision or instruction 
concerning use of the appliance by 
a person responsible for their safety. 
Children should be supervised to ensure 
that they do not play with the appliance.

AGI A/W

15

Содержание AGI A Series

Страница 1: ...AGI 12 SE 14 GB...

Страница 2: ...A W 2 L L 2 25 25 25 25 575 75 75 485 185 730 300 160 M10 Horizontal mounting Connection dimensions inside thread 1 DN25 1 1 4 DN32 AGI2 X AGI3 X AGI4 X AGI5 X L mm AGI2 1200 AGI3 1800 AGI4 2400 AGI5...

Страница 3: ...GI A W 3 300 485 185 730 160 50 L 25 25 25 75 75 575 25 Vertical mounting Connection dimensions inside thread 1 DN25 1 1 4 DN32 AGI2 X AGI3 X AGI4 X AGI5 X L mm AGI2 1200 AGI3 1800 AGI4 2400 AGI5 3000...

Страница 4: ...AGI A W 4 296 717 50 302 5 56 56 302 5 18 14 148 148 8x 13 2 min 300 mm Fig 1 Fig 2...

Страница 5: ...speed RTI2 85 811 44 Electronic thermostat IP44 T10S 85 809 33 672 84 99 Room thermostat IP30 KRT1900 85 810 12 672 70 40 Room thermostat IP55 MDC 87 511 98 Magnetic door contact with time relay IP44...

Страница 6: ...U V TK W TK PE U V TK W TK PE U V TK W TK PE U V TK W TK PE Fan 2 Fan 3 Fan 4 Fan 5 M 3 PE L1 L2 L3 5 6 6 5 6 5 6 5 6 5 AGIV5 AGIH5 13 14 AGB Wiring diagram valid for all AGI Number of motors correspo...

Страница 7: ...PE U V TK W TK PE U V TK W TK PE U V TK W TK PE Fan 2 Fan 3 Fan 4 Fan 5 M 3 PE L1 L2 L3 5 6 6 5 6 5 6 5 6 5 AGIV5 AGIH5 230V A B 2 4 4 t C 6 2 7 T10S 13 14 AGB 1 2 3 KRT1900 Wiring diagram valid for...

Страница 8: ...options Level 2 RTI2 TVVS20 25 SD20 MDC RTRDU AGIV5 AGIH5 230V 230V 400V3N Wiring diagram valid for all AGI Number of motors corresponds with the number in the type label To terminals L1 L2 and L3 in...

Страница 9: ...AGI A W 9 Wiring diagrams AGI W Convertible connection 230V3...

Страница 10: ...28 5 34 0 0 19 0 7 44 5 44 4 0 54 4 3 AGI5WL max 17500 100 9 45 0 0 98 6 3 110 4 36 7 1 34 11 1 min 6300 36 1 34 9 0 25 0 5 56 1 44 4 0 68 3 2 Supply water temperature 60 C Room temperature 18 C Outl...

Страница 11: ...IH2A 0 7000 69 400V3 2 4 1200 51 AGIH3A 0 10500 71 400V3 3 5 1800 75 AGIH4A 0 14000 72 400V3 4 7 2400 97 AGIH5A 0 17500 73 400V3 5 9 3000 120 Type Output 3 kW Airflow m3 h t 2 3 C Water volume l Sound...

Страница 12: ...Electrical installation The installation which should be preceded by an omnipolar switch with a contact separation of at least 3 mm should only be wired by a competent electrician in accordance with t...

Страница 13: ...se order to the above Draining the water coil AGI W The drain valve is on the underside of the coil on the connector side It can be accessed via the service hatch Troubleshooting If the fans are not w...

Страница 14: ...CH Main office Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact w...

Отзывы: