Frico 74684 Скачать руководство пользователя страница 2

FCBC 

FCSC

FCDC

FCWTA

FCTXRF

FCLAP

FCSC10

FCRTX

FCSC10

FCOTX

FCBC10

FCBC05

FCDC

FCCF

FCPA - FC Pro

FCBA - FC Building

FCBC10

FCDC

FCCF

FCLAP

FCBC10

FCDC

FCCF

FCLAP

FCTXRF

FCBC10

FCDC

FCCF

FCBAP

FCCF control panel 

2

FC Frico Control - Quick guide

 

74684

FCDA

89x89x26 mm (FCCF)

74685

FCSA

89x89x26 mm (FCCF)

74686

FCPA

89x89x26 mm (FCCF)

74687

FCBA

89x89x26 mm (FCCF)

FCDA - FC Direct

FCSA - FC Smart

74694

FCRTX

39x39x23 mm

74695

FCOTX

39x39x23 mm

74699

FCLAP

89x89x26 mm

74718

FCBC05

5 m

74719

FCBC10

10 m

74720

FCBC25

25 m

74721

FCSC10

10 m

74722

FCSC25

25 m

17495

FCDC

74703

FCTXRF*

89x89x26 mm

74702

FCWTA
FCBAP

149x149x43 mm

EN

FC Control system 

External room temperature sensor 
Outdoor temperature sensor
Local access point for extra sensors and extended range 
Extra communication cable, 5 m
Extra communication cable, 10 m
Extra communication cable, 25 m
Extra sensor cable, 10 m
Extra sensor cable, 25 m
Door contact 
Indoor/outdoor wireless sensor (for FC Smart, FC Pro) 
Return water temperature sensor  
Building access point 

Item 

number

Type 

Description 

Dimensions 

*The wireless sensor can be set up as outdoor or indoor sensor by a switch inside the sensor. 

Control system content and accessories 

The air curtain must be supplemented with a control system. 

FC Direct, first level control system 
FC Smart, second level control system 
FC Pro, third level control system

FC Building, BMS system

FC Control system helps to create many smart and energy saving features. In addition to our 

four packages, components can be added to expand and customize the system. 

Item 

number

Type 

Description 

Dimensions 

Содержание 74684

Страница 1: ...Control system FC Quick Guide FCDA FC Direct FCSA FC Smart FCPA FC Pro FCBA FC Building EN...

Страница 2: ...ensor Local access point for extra sensors and extended range Extra communication cable 5 m Extra communication cable 10 m Extra communication cable 25 m Extra sensor cable 10 m Extra sensor cable 25...

Страница 3: ...D GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 Com NO NC BLK GRY RED G 1 2 Sensor...

Страница 4: ...AP Set up in Setup Guide FCDC SDM VPFC VMFC FCWTA Config input PC Board inside air curtain A1 A2 B1 B2 GND GND GND GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS...

Страница 5: ...HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 FCDC Com NO NC FCWTA BLK GRY RED SDM VPFC VMFC GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V FCLAP Config in...

Страница 6: ...GND GND GND GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 Com NO NC BLK GRY RED S G...

Страница 7: ...erference the communication BUS should be terminated at each end i e in the units that are located at the start and at the end of the BUS respectively On delivery all buses are pre connected with a 12...

Страница 8: ...mation FCOTX FCTXRF outdoor temperature signal in FCBAP heating is automatically blocked when the outdoor temperature exceeds 15 C The set point can be changed and this function can be deactivated see...

Страница 9: ...ay the set point temperature The FC control is delivered with preset values The preset set point temperature is 21 C and can be easily adjusted using the up down arrows Normal mode Comfort mode Comfor...

Страница 10: ...n speed 0 100 Auto 0 3 Auto Auto requires outdoor temperature information FCOTX FCTXRF outdoor temperature signal in FCBAP Fan menu Browse between the menu options Confirm Home screen Press twice to a...

Страница 11: ...closes Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Fan speed if there is a need for...

Страница 12: ...Quick guide 12 EN User menu See the table on the following page for the possible choices Press to activate keypad Confirm Exit without saving or Press and hold for 2 seconds Browse between the menu op...

Страница 13: ...arrow Confirm each step with OK Switch between OFF and P1 P9 with up down arrow Confirm with OK off function not activated Switch heating on off Switch between On and OFF with up down arrow Confirm wi...

Страница 14: ...temporary set point temperature Confirm The temporary set point temperature will apply until the next program step Power failure Note A power loss longer than 7 days may require an adjustment of time...

Страница 15: ...ted 1 function activated Automatic time change over Press to activate keypad Press and hold for 2 seconds After run speed fixed Fan speed in fixed after run mode After run speed Auto low Low fan speed...

Страница 16: ...1 enabled Outdoor temperature heat blocking set point Set point for Outdoor temperature heat blocking in 0 1 C Block water bypass due to outdoor temperature 0 disabled 1 enabled If enabled the water...

Страница 17: ...ed Controls the return water temperature Requires return water temperature sensor and mobile app Return water temperature set point Requires return water temperature sensor and mobile app Actuator exe...

Страница 18: ...nsor fault Fault on the control panel s temperature sensor Incorrect sensor connection Outdoor temperature sensor fault Error code Action Cause Control panel communication error Reset alarm To reset m...

Страница 19: ...cal supply Check the overheat protection see manual for the air curtain Clean the filter Reset the alarm manually Replace the batteries A 35 A 36 A 37 A 38 A 39 A 33 BMS communication error BMS invali...

Страница 20: ...08 EV CH Main o ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www f...