General Instructions 

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions. 

 

Application 

The infrared heater IH is powerful with a 
high filament temperature of 2200 °C and 
is the perfect choice for exposed outdoor 
environments where design is important. IH 
is available in two different designs. IHW gives 
a comfortable heat in the occupied zone from 
close range and also wider heat distribution. 
IHF has more direct heat distribution and is 
designed to be installed higher up.
Protection class: IP44.  
 

Positioning  

The heaters must be placed so that they 
cover the area to be heated, see fig. 1. The 
normal mounting height is 2–3 metres above 
the ground/floor. A rule of thumb for infrared 
heaters is that 600–800 W/m² increases the 
experienced temperature by about 10 °C. The 
output demand can be reduced if the area to 
be heated is protected. If the area only has a 
roof, at least 800 W/m² should be installed. 
600 W/m² is sufficient if the area has three 
walls. For enclosed areas, the output demand 
must be calculated. Optimum comfort is 
achieved if the heat is distributed from at 
least two directions.

IHW provides wide heat distribution (60°), 

recommended installation height 1.8 – 2.5 m. 
IHF provides directed heat distribution (40°), 
recommended installation height 2.3 – 3.5 m. 

Start-up 

When the unit is used for the first time or 
after a long period of disuse, smoke or odour 
may result from dust or dirt that has collected 
on the element. This is completely normal 
and disappears after a short time. 
 

Mounting 

IH is installed horizontally on walls with 
supplied bracket. The heater can be angled 
up to 45°. The heater can also be mounted 
on e.g. a parasol or a post, a suitable U-bolt 
(not included) is used for this together with 
the supplied console. For ceiling installation 
use ceiling bracket IHE (accessory). For other 
mounting alternatives, see accessories.  
For minimum distances, see diagrams on 
introductory pages. 
 
1. Secure the bracket on the wall with at least 

2 screws. If the keyhole slots are used, an 
addition screw is needed to fix the bracket. 
See the introduction pages.  

2. Remove the screws fixed to the unit's back 

on delivery.  

3. Hook the unit on the bracket. 
4. Lock in position with the screws.   

Connection  

IH is equipped with a 0.9 metre cord with 
plug for connection to an earthed outlet 
socket. 

The connection cord must not rest against 

the unit as the surface becomes hot or can 
be hit by thermal radiation. Contact an 
electrician if the cord needs to be changed. 
Note that due to the high temperatures in the 
heater, a cord of the type H05 RN-F 3G1 mm² 
or the like should be used. 

As the halogen lamp has a high starting 

current the wall socket should be fuse 
protected by a slow burn fuse.  

In the event of uncertainty contact an 

electrician. 

Содержание 11878

Страница 1: ...IH Original instructions 7 EN 10 SE 13 NO 16 FR 20 DE 24 ES 28 NL 32 IT 36 PL 40 RU 44 FI ...

Страница 2: ...en DE Las páginas introductorias contienen básicamente imágenes Consulte la traducción de los textos en inglés que las acompañan en las páginas del idioma correspondiente ES De inleidende pagina s bevatten hoofdzakelijk afbeeldingen Voor een vertaling van de gebruikte Engelse teksten zie de pagina s van de resp taal NL Le pagine introduttive contengono prevalentemente immagini Per le traduzioni de...

Страница 3: ...00 676 169 160 0 9 77 147 Positioning Fig 1 The heaters should heat from at least two directions for even heating 46 5 60 115 24 ø8 17 5 25 5 35 Dimensions 2 3 3 5 m 1 8 2 5 m Installation height Wallbracket ...

Страница 4: ...IH 4 1 3 3 4 5 2 1 Replacing the lamp Minimum mounting distance 200 180 min 30 1800 300 1000 160 500 IHE ceiling bracket Flammable material ...

Страница 5: ...16976 IHXL 11887 IHT 16974 IHTW 16970 IHP 92865 KLS1KS 93272 IHAF 220646 IHL1000 220647 IHL1500 206496 IHL2000 KLS1KS IHAF IHUB IHXH IHXL IHT IHTW IHE IHP IHP IHT IHL Controls 92867 IHBD3 10740 CBT IHBD3 CBT IHT See separate manual See separate manual ...

Страница 6: ...eater IHF with directed heat distribution IP44 Item number Type Heat output W Voltage V Amperage A Max filament temperature C Length mm Weight kg 11881 IHF10 1000 230V 4 3 2200 500 1 9 11882 IHF15 1500 230V 6 5 2200 500 1 9 11883 IHF20 2000 230V 8 7 2200 676 2 5 Wiring diagrams Timer control Timer control with contactor N IH IHC 1 2 3 CBT L N L N IH IHC L N IH IHC L 230V Max load 3500W N IH IHC 1 ...

Страница 7: ...distribution 60 recommended installation height 1 8 2 5 m IHF provides directed heat distribution 40 recommended installation height 2 3 3 5 m Start up When the unit is used for the first time or after a long period of disuse smoke or odour may result from dust or dirt that has collected on the element This is completely normal and disappears after a short time Mounting IH is installed horizontall...

Страница 8: ...rect output and voltage 9 Fit the new lamp Note do not touch the lamp with your fingers wear gloves or the like 10 The protective tube must be refitted to the cables so that the cables are not damaged when the grille is fitted 11 Reassemble the unit again See the introduction pages Residual current circuit breaker When the installation is protected by means of a residual current circuit breaker wh...

Страница 9: ...of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less...

Страница 10: ...020 04 20 HH CH Main office Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net ...

Отзывы: