Contents of the package

Thank you for choosing a FRIAX's Monobloc system to control the aging of your wine.
Take the  me to read this manual. It will help you understand the steps to install and adjust the MPC series.

What is a cellar Monobloc system FRIAX ?
The MPC serie is a refrigera on system specially designed to keep the op mum temperature and humidity at 
the aging of your wines. The system is composed of three essen als elements which are the evaporator, the 
condenser unit and the regula on box. These elements are interconnected by a refrigerant pipe and an 
electrical connec on.

At the delivery, you must 

fi

nd in your package, your Monobloc, the installa on manual and the accessories 

describde on page 3. Check package to detect any damage on the carton. Note on the delivery of the carrier all 
the observa ons about the package condi on, this could be useful in case of damage.
If in doubt contact your dealer.
When unpacking check that the material inside the package corresponds to the checklist on the box.

Safety

-Be sure to install the unit in a sheltered place.
-It is advisable to remove the device from its packaging with the help of someone.
-Connect the power supply once the en

Ɵ

re installa

Ɵ

on is complete.

O

 pallet dimensions:

 750 mm x 490 mm x 510 mm ( P x L x H)

Содержание MPC Genesis Series

Страница 1: ...Genesis Vintage Les caract ristiques donn es dans cette fiche technique peuvent voluer sans avis pr alable avec les am liorations que FRIAX Industrie entend toujours apporter sa production GB NT MPCA...

Страница 2: ...on box These elements are interconnected by a refrigerant pipe and an electrical connec on At the delivery you must find in your package your Monobloc the installa on manual and the accessories descr...

Страница 3: ...C 4 18 C Weight 45 kg 49 kg Current cooling mode 2 41 A 3 24 A 210 m3 h 210 m3 h Temperature se ng range Airflow outside 250 m3 h 250 m3 h Power cable lenght Genesis Vintage Genesis Condensate evapor...

Страница 4: ...260 48 42 204 19 243 567 198 75 285 43 25 350 253 26 374 139 Evaporator air inlet Regulation LED synchronization button Power Supply Condenseur air outlet Evaporator air outlet Condensor air inlet Dim...

Страница 5: ...MPCA Genesis Vintage Installation Position of the opening in the bottom of the cabinet 5 90 mini 285 75 43 5 1 3 260 23 199 75 199 260 23 285 60...

Страница 6: ...MPCA Genesis Vintage Installation 6 567 570 between cleat 60 mini 480 mini 11 60 90...

Страница 7: ...lation Connec on of the drain Only units not equipped with the KBEC op on condensate evapora on pan kit must be connected to a drain Connect the drain Connect the drain tube 16 to the end of the elbow...

Страница 8: ...The remote control could be installed in any room Its maximum range is 100m in a completely open area This distance could be extremly reduced by thickness of walls and the loca on of the cellar It is...

Страница 9: ...ature or humidity indicator option Battery charge level indicator C F or humidity unit indicator Speed condensor fan Speed evaporator fan Time 12 AM PM or 24 h existing if EC evaporator fan existing i...

Страница 10: ...Access to menu Parameters Display Handling See below the value set according to the device Login with Shorten the wai ng period hold Start the unit with the remote control The unit starts in hea ng or...

Страница 11: ...ired setpoint tempera ture Returns to the display of measured values in the cellar OK confirm with OK confirm with Change the value with or Change the value with or Step III Set the cellar temperature...

Страница 12: ...o its normal speed Manipula on bu ons no longer possible to change the se ngs Bu ons are accessible to change the se ngs The screen turns o a er a few seconds The appliance con nues to operate The scr...

Страница 13: ...display on 24 Access to menu Parameters Display Handling OK OK confirm with Change the value with or Login with OK OK confirm with Change the value with or Login with OK OK confirm with OK confirm wit...

Страница 14: ...ameter is set to 0 at the factory It may be modified only in the case where there would be a gap between the moisture displayed and the real humi dity of the cellar Only available on model Vintage Let...

Страница 15: ...ower threshold wine cellar temperature type 1 Upper threshold wine cellar temperature type 1 Faulty wine cellar temperature type 2 Vintage temperature signal lost type 2 type 1 type 1 Upper threshold...

Страница 16: ...6 months opera ons will allow your air condi o ner MPC keep its op mal ways to ensure its longevity and your wines CAUTION Before any maintenance work switch o the power supply to the main circuit br...

Страница 17: ...ture sensor Temperature humidity sensor on Vintage series GND PWM1 TAC CP HGR KCH EVF CDF POWER Sonde cond T L L L L L N N N N N blue Yellow White Blue Blue Black Black 5 x 20 10A GT L N T HGR or On V...

Страница 18: ...f 1 Compressor 30050077 2 Remote PR20050067 3 Control board PR20050070 4 Light switch PR20070008 5 Probe C HRG 20050002 20070035 6 Fan PR20080082 7 Drip tray 40010274 Bent hose PR60010039 Condensate p...

Страница 19: ...REQUIREMENTS OF THE FOLLOWING EUROPEAN MEASURES AND THEIR MODIFICATION 2014 35 EU Basse Tension 2014 35 EU Low Voltage 2014 30 EU Compatibilit lectromagn tique 2014 30 EU Electromagnetic compatibilit...

Страница 20: ...Site web www friax fr Boite mail friax fr info R INDUSTRIE 231 233 Rue de la Prairie F 73420 Voglans D couvrez notre de cave de rangement pour la cave site web www visiorack com...

Отзывы: