EVX2

Genesis-Vintage

 2

Ce symbole indique que le manuel d’installation doit être lu attentivement.

This symbol indicates that the installation manual should be read carefully.

Ce symbole indique qu’un technicien de service doit manipuler cet équipement en

se référant au manuel d’installation.

This symbol indicates that a service technician should handle this equipment in

referring to the installation manual.

Ce symbole indique que des informations sont disponibles, telles que le manuel 

d'utilisation ou le manuel d'installation.

This symbol indicates that information is available, such as the manual

operating instructions or installation manual.

Avertissement 

Warning

Veillez à installer l’appareil dans un endroit à l’abris des intempéries et hors gel.

Make sure to install the device in a place protected from bad weather and frost.

Une installation ou utilisation incorrecte, peuvent entraîner des blessures aux personnes, des  dommages aux biens, et 

l’annulation de la garantie constructeur. Le non-respect des consignes  de sécurité et des normes locales en vigueur lors 

de l’installation ou utilisation décharge le fabricant de toute responsabilité.

Improper installation or use can result in injury to persons, damage to property, and cancellation of the manufacturer's 

warranty. Failure to follow instructions  safety and local standards in force during installation or use discharges themanu-

facturer of any responsibility.

- Sachez que certains gaz réfrigérants peuvent être inodores.

- Toute intervention sur un circuit frigorique doit être réaliser par un professionnel autorisé par un organisme accrédité 

certifiant la compétence à manipuler les fluides réfrigérants.

- Be aware that some refrigerant gases can be odorless.

- Any intervention on a refrigeration circuit must be carried out by an authorized professional by an accredited body 

certifying the competence to handle refrigerant fluids.

- L’appareil doit être en permanence libre de toute obstruction pour en assurer le bon fonctionnement et réduire les 

risques en matière de sécurité.

- Ne perforez aucun composant du circuit réfrigérant.

- Faites preuve de prudence lors de la manipulation de l’équipement pour éviter tout dysfonctionnement.

- The device must be free of any obstruction at all times to ensure good operation and reduce safety risks.

- Do not puncture any component of the refrigerant circuit.

- Use caution when handling equipment to avoid malfunction.

- L’appareil doit-être installé conformément aux réglementations locales en matière de câblage.

- Assurez-vous que les caractéristiques de l’appareil sont compatibles avec celles de l’installation électrique.

- Assurez-vous que la prise secteur est raccordée à la terre.

- N’utilisez par l’appareil s’il est endommagé

- Ne branchez l’alimentation électrique qu’une fois toute l’installation achevée.

- Eteignez toujours l’appareil et débranchez-le du secteur pour le nettoyage et la maintenance.

- Ne mettez pas vos mains ou d’objets dans les entrées et sorties d’air.

- N’essayez pas de réparer vous-même l’appareil.

- Toute utilisation et/ou modification non agréée par le fabricant peut s’avérer dangereuse pour votre sécurité et votre santé.

- Cet appareil ne doit pas être utilisé par des enfants.

- L’utilisateur doit comprendre et être conscient des danger potentiels liées à l’utilisation de l’appareil.

- N’utilisez que les moyens et/ou outils recommandés par le fabricant pour le dégivrage ou le nettoyage.

- The device must be installed in accordance with local wiring regulations.

- Make sure that the characteristics of the device are compatible with those of the electrical installation.

- Make sure that the mains socket is connected to earth.

- Do not use the device if it is damaged

- Do not connect the power supply until the entire installation is complete.

- Always switch off the appliance and unplug it from the mains for cleaning and maintenance.

- Do not put your hands or objects in the air inlets and outlets.

- Do not try to repair the device yourself.

- Any use and / or modification not approved by the manufacturer may be dangerous for your safety and health.

- This appliance must not be used by children.

- The user must understand and be aware of the potential dangers associated with the use of the device.

- Use only the means and / or tools recommended by the manufacturer for defrosting or cleaning.

Содержание EVX2

Страница 1: ...trie in a constant endeavour to improve its products reserves the right to change any information contained in this leaflet without prior warning EN NT EVX2 1121 Installation manual SPC EVX2 WEVX2 Gen...

Страница 2: ...e perforez aucun composant du circuit r frig rant Faites preuve de prudence lors de la manipulation de l quipement pour viter tout dysfonctionnement The device must be free of any obstruction at all t...

Страница 3: ...sis Vintage THANK YOU for trusting Friax Industrie for the conservation of your wines Our air conditioners are designed for the comfort of wine above all but do not forget the user Once installed in t...

Страница 4: ...of the ceiling and walls between 60 and 80 mm of PU for a device installed in the wall of the cellar Under the following conditions 12 C in the cellar 35 C outside IMPORTANT The cooling capacity and t...

Страница 5: ...level at 5m 2 x1 2 M 2 x1 2 M 225 335 Amax 5 1 4 2 6 5 1 Max Intensity of AIR Water group SPC EVX2 30 48 W 780 1100 W Heating capacity Cooling capacity 800 800 R134A Power absorbed in heating Power a...

Страница 6: ...be necessary to add a siphon every 2m of height Do not add oil unless the network of refrigerant s length exceed 10m in this case use the oil recommended by FRIAX Industrie Auf den horizontalen F hrun...

Страница 7: ...ass located to the dehydrator Complete load slowly until the bubbles disappear Tighten caps Schraeder Die Verbindung im Rohrnetz ausf hren Schnittstellen flare Nach dem Anschluss ziehen Sie den Vakuum...

Страница 8: ...y 300 150 250 A Clearance of air without obstacle A minimum 2500 150 109 502 489 A 2500 488 453 488 01 Setting up 160 160 200 200 01A Wall fixation Depending on the layout constraints below select you...

Страница 9: ...EVX2 Genesis Vintage 01B Fastening system Plug Lock 265 339 66 01C Ductable with KFG GCG and KGR160 KR kits See List of accessories on pages 11 to 12 Air group installation GCG 9...

Страница 10: ...frigorif re 10 EVX2 Genesis Vintage Water connections 15 21 Compressor fan 565 605 510 BNS 25 380 440 02A Fastening system Plug Lock 225 58 180 180 The installation of the Low sound level kit must be...

Страница 11: ...le sheath insulated with 200 glass wool KGS200 or Semi rigid polyethylene sheath 180 KGR180 Semi rigid polyethylene sheath 160 KGR160 Flexible sheath insulated with 160 glass wool KGS160 Using the tab...

Страница 12: ...48 Low noise BNS kits for Air group 30 48 low noise level BNS water group kits 30 to 230 REF BNS 82 122 Sheet metal background mousse B mousse C 1 U galva mousse A galvanized angle See assembly instru...

Страница 13: ...ve a minimum of 25 cm of space around the device so as not to obstruct the air ow and obtain an optimal ow rate For a perfect di usion it is advisable to install the air conditioner in height any othe...

Страница 14: ...ase it is recommended to use the KPR XJ lifting pump kit in order to evacuate the condensate outside the cellar 459 280 Secure the device to the wall using screws suitable for the support not supplied...

Страница 15: ...ns Cellar evaporator installation Cellar probe Temperature Humidity Power supply Condensor probe Cellar side connection hole KLED XJ power supply Condensate recovery tray Heating resistance Lift pump...

Страница 16: ...nnection kit for humidi er KLPWSECU XJ For VINTAGE units it is recommended to install this kit to protect against leaks and excessive water ow to the humidi cation system Water inlet Max 10 bars 21 C...

Страница 17: ...oop Vintage Vintage LED backlight kit KLED XJ Connection KIT KLED XJ Support transfo KIT KLED XJ EVX2 Genesis Vintage Cellar evaporator installation To switch ON OFF On the remote control push for 5 s...

Страница 18: ...ar as it will go to connect flexible conductors The connection of the rigid cables is carried out by direct insertion Snap the wired connector into the lower part of the discharge housing traction Enc...

Страница 19: ...derstand Unit ext rieure Outdoor unit Schaltkasten Blanc White wei Variateur de Viesse EC Fan speed Controler L fterdrehzahlregler BP HP N 1 ou Brun N 2 ou Noir N 3 ou Bleu COND SHGR POWER SUPPLY CDF...

Страница 20: ...nd Unit ext rieure Outdoor unit Schaltkasten Blanc White wei Variateur de Vitesse EC Fan speed Controler L fterdrehzahlregler BP HP N 1 ou Brun N 2 ou Noir N 3 ou Bleu COND SHGR POWER SUPPLY CDF L N H...

Страница 21: ...sed of properly you help avoid the conse quences potentially harmful to the environment and human health Please contact your installer or local authorities for more information Warning 05 Close the de...

Страница 22: ...t from the battery be careful not to damage the ns Before closing check that there are no foreign objects leaves etc that could interfere with the proper functioning of the appliance Turn on the power...

Страница 23: ...OF THE FOLLOWING EUROPEAN MEASURES AND THEIR MODIFICATION 2014 35 EU Basse Tension 2014 35 EU Low Voltage 2014 30 EU Compatibilit lectromagn tique 2014 30 EU Electromagnetic compatibility 2014 68 EU...

Страница 24: ...24 Expert Fran ais du vin www friax fr D couvrez notre gamme de rangement pour la cave www visiorack com...

Отзывы: