background image

www.friatools.com

OPERATING INSTRUCTIONS

FRIAMAT PRIME ECO

  

Содержание FRIAMAT PRIME ECO

Страница 1: ...www friatools com OPERATING INSTRUCTIONS FRIAMAT PRIME ECO...

Страница 2: ...ation site 8 2 9 Emergency 8 3 Basic information 9 3 1 Layout parts 9 3 2 Function keys explained 10 3 3 Display 11 3 4 Function key symbols explained 12 3 5 Function status symbols explained 13 3 6 T...

Страница 3: ...enu 24 5 3 Data submenu 24 5 3 1 Transfer submenu 25 5 3 2 Delete submenu 26 5 4 Fusion options 26 5 4 1 ID Data menu 26 5 4 2 Traceability Barcodes Pipe Number Pipe Length 28 5 4 3 Info Data Info Tex...

Страница 4: ...safety fittings with HDPE pressure pipes SDR 17 7 FRIALEN XL large pipe installations with HDPE pressure pipes SDR 17 7 and FRIAFIT sewage fittings with HDPE sewage pipes SDR 17 33 FRIAMAT fusion unit...

Страница 5: ...AMAT fusion unit Safety considerations forbid the following modifications and changes to the FRIAMAT fusion unit and working with FRIAMAT fusion units with broken lead seals Failing to observe the abo...

Страница 6: ...n this is prescribed Do not remove or otherwise put safety installations out of operation Immediately eliminate identified defects WARNING Danger of fire and explosion from highly flammable materials...

Страница 7: ...nt series exhibit highly diverse control characteristics The suitability of a specific generator therefore cannot be safeguarded even when it provides the required rated power output according to its...

Страница 8: ...nger of death Never open the FRIAMAT fusion unit when it is supplied with operating voltage FRIAMAT fusion units may be opened only by specialised personnel from an authorised FRIATEC service station...

Страница 9: ...1 2 3 4 5 8 6 7 1 Main switch 2 Fusion cable with reader wand 5 Ventilation slots air outlet or barcode scanner 6 Adapter bag 3 Front foil with display 7 Power cable and function keys 8 Ventilation s...

Страница 10: ...tion keys left right up down let you move the cursor through the menu structure The selection is confirmed with OK or one of the function keys 3 START key The START key is used to start a fusion proce...

Страница 11: ...ance see also Section 6 2 2 View ambient details Key ambient details are shown date time ambient temperature voltage and frequency 3 Main window The main window presents all inputs and details in each...

Страница 12: ...ntext OK Confirm Apply Save Select a menu item Cancel key This ends an input and closes the dialog without saving Back key This takes you one step back in a menu sequence or input without changes Next...

Страница 13: ...fusion barcodes and traceability barcodes place the reader wand under a slight angle like a pencil in front of the barcode on the fitting Now move the reader wand quickly over the whole label and a l...

Страница 14: ...rotective cap for data interface The USB port is found directly behind the protective cap This data interface functions as a service port The protective cap for the data interface must be screwed on a...

Страница 15: ...e fans can then reduce the heat sink temperature 3 12 FRIAMAT preCHECK function Before every fusion process the FRIAMAT calculates from the fitting parame ters the current device status and the ambien...

Страница 16: ...ng temperature range 20 C 50 C Fusion current monitoring short circuit 110 A short circuit 1 70 x IN interrupt 0 25 x IN Fusion voltage max DC 48V Data transfer interface USB Bluetooth prepared Protoc...

Страница 17: ...fusion INFORMATION The leading maintenance date is always shown on the display and may differ from the details on the service label attached to the FRIAMAT fusion unit 3 16 Transport storage dispatch...

Страница 18: ...applies to the device fusion and extension cables 4 Connect the device to the power supply mains or generator To do so insert the device s plug into the socket 5 If necessary use an extension cable Ma...

Страница 19: ...turer and the same charge In cases of doubt contact the fitting manufacturer s hotline NOTE It is forbidden to read in a replacement barcode on a different fitting 3 Read in the barcode with a reader...

Страница 20: ...ese must be checked and confirmed by the user 3 Press the START key to initiate the fusion procedure The ambient temperature is measured and the resistance of the connected fitting determined Check ap...

Страница 21: ...r Time Date Language and Volume 5 Press the Confirm function key or OK 6 Use the function and direction keys to make your changes and edit the settings 7 Press the Confirm function key or OK to save y...

Страница 22: ...n the operator pass the system opens the ID Data submenu see also Section 5 2 4 The direction keys scroll through the settings activated on the FRIAMAT prime eco The operator pass can be used to lock...

Страница 23: ...ntered for the fusion operation on each of the pipes 5 2 3 Info Data submenu The Info Data submenu lets you enter additional information relevant to each of the fusion operations 5 2 3 1 Info Text The...

Страница 24: ...sion Number activated the ID Data menu ID Data key lets you select a Commission Number or enter a new number either manually or in the form of a barcode The selected order number then appears in the d...

Страница 25: ...port Filter dialog 5 Press the function Next key to select the output format dialog Transfer Data 6 In the menu Transfer Data define the output formats CSV PDF and or FTD 7 The display prompts the ope...

Страница 26: ...m numbers can be entered only when documentation and the functions Commission Number see Section 5 2 4 1 and Seam Number see Section 5 2 4 2 habe been activated 5 4 1 1 Commission Number 1 Press the I...

Страница 27: ...ss the Input Emergency Input function key 4 Enter each of the numbers from the first to the last using the direction keys on the virtual keypad When finished press OK 5 Press the Confirm function key...

Страница 28: ...ain window prompts you to enter the traceability barcode on the fitting When this is being read in you are prompted to enter the traceability barcode on Component 1 When Pipe Number and or Pipe Length...

Страница 29: ...ed press OK 5 Press the Confirm function key to save the entered numbers the Cancel function key to abort the input or the Backspace function key to delete preceding numbers 6 Press the OK function ke...

Страница 30: ...you enter the fusion barcode manually 1 Press the Input Emergency Input function key 2 Enter each of the numbers in the barcode using the direction keys on the number pad now appearing When finished p...

Страница 31: ...k function Before every use Operator Check and if necessary clean or exchange contacts Before every use Operator Factory maintenance Yearly FRIATEC GmbH or authorised service stations 6 3 Disposal The...

Страница 32: ...range Ambient temperature outside of permitted range You may have to tent over or shield the fusion area 03 Resistance outside of tolerance Fitting s electrical resistance outside of tolerance Check t...

Страница 33: ...y of the FRIAMAT Contact the FRIATEC service hotline 49 0 621 486 1533 17 19 System error Contact the FRIATEC service hotline 49 0 621 486 1533 23 Generator error Generator possibly not suitable for f...

Страница 34: ...ncorrect barcode Use a new barcode on an identical fitting or correct the entered code manually Let the device cool down Protective function that prevents the device from overheating Let the device co...

Страница 35: ...cal information contained in these operating instructions is examined regularly for currency The date of the last revision is specified on every page The latest operating instructions can be viewed on...

Страница 36: ...2522 Stand Update 01 2019 FRIATEC GmbH Technical Plastics Division P O B 71 02 61 D 68222 Mannheim Telefon 49 621 486 1533 Telefax 49 621 486 2030 info friatools friatec de www friatools com...

Отзывы: