Installation:
•
North American units must be installed conform local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1, as applicable, including:
i) The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
ii) The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
•
North American units must when installed be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electric Code, NFPA 70, or the
Canadian Electrical Code, CSA C22.2, as applicable.
•
North American units equipped with casters must be installed with connectors that comply with
the Standard for Connectors fo
r Movable Gas Appliances, ANSI Z21.69 • CSA 6.16. This
connection must include a quick disconnect device that complies with the Standard for Quick
Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 • CSA 6.9.
•
Adequate means must be provided to limit the movement of the appliance without depending on
the connector and quick-disconnect device or its associated piping to limit the appliance
movement. The restraining device should be attached to the appliance tether bracket.
restraining suggestion
•
A water connection with an aerated valve with a ¾ inch thread connection, with a minimum
continuous flow rate of 15 liters / min, must be available near the unit. The water pressure must
be between 200 and 500 kPa (2 and 5 bar), preferably at least 300 kPa (3 bar). Refer to the
Installation Manual.
•
Use the water hose supplied with the machine.
•
An open drainage with a diameter of at least 40 mm (1.6 inch) must be available near the unit.
•
The unit has a mains plug, and must be connected to a wall socket with the proper mains voltage.
The wall socket must be mounted by a certified electrician.
•
A Gas supply with a 1/2 inch NPT connection must be available near the unit.
•
Use the GAS pipe supplied with the machine.