Fri-Jado 120-2-C FS Скачать руководство пользователя страница 7

MCC 

 Cold / Ambient

 

EU 

7/40 

  To avoid short-circuiting, never clean the unit using a water hose.  For cleaning instructions, 

see section 5. 

  The  Cold  unit  must  be  cleaned  regularly  to  ensure  proper  functioning  and  to  avoid  the 

outbreak of fire (overheating).  Especially the back of the fan plate. 

  Do not store explosive substances such as aerosol cans with flammable propellant in this 

appliance. 

  This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and  persons  with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 
have been given supervision or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. 

  Children shall not play with the appliance. 

  Cleaning and user maintenance shall not be performed by children without supervision. 

 

1.4.2  Self-contained cold units with R290 (propane) refrigerant 

 

 

Propane refrigerant is environmentally friendly but also highly flammable.  It is non-
toxic  with  zero  Ozone  Depletion  Potential  (ODP)  and  very  low  Global  Warming 
Potential (GWP). 

Read this manual carefully and follow all precautions described herein.

 

 

 

R290 

WARNING  

The propane refrigerant is highly flammable

.  All safety precautions must be followed. 

Keep  all  ventilation  openings  in  the  housing  of  the  appliance  or  in  the  installation 
unobstructed. 

Do not use mechanical devices or other means to accelerate the defrosting process, 
other than those recommended by the manufacturer. 

Do not damage the refrigerating circuit. 

Do  not  use  electrical  appliances  inside  the  food/ice  storage  compartments  unless 
they are of the type recommended by the manufacturer. 

Propane refrigerant does not contain odorants. 

 
 

 

SAFETY

 

Wear eye protection when working on the refrigeration system. 

 

  Install the unit in a well ventilated area with sufficient floor space: refer to the data plate for 

minimum space requirement. 

 

Do not install the unit in basements, in area’s with open flames or high surface temperatures.  

  Do not tamper with the system. 

  The system must be installed and maintained by qualified persons only. 

  The  ventilation  openings  of  the  cladding  of  the  unit  (including  accessories)  must  not  be 

blocked or covered.  Ensure that the air circulation remain unobstructed. 

  Electrical devices used within this unit must be certified by the applicable ATEX directive. 

 

Residual risks: 

  Sparks  from  electrical  devices  or  hot  surfaces  may  unintentionally  ignite  possible  leaked 

refrigerant gas. 

 

 

 

Содержание 120-2-C FS

Страница 1: ...MCC Cold Ambient EU EN Original Instruction 9124736 2207 USER MANUAL Modular Convenience Counter Cold Modular Convenience Counter Ambient WARNING Read the instructions before using the machine...

Страница 2: ...al As a result of constant commitment to improvement it may happen that your unit deviates in detail from what is described in this manual For this reason the given instructions are only a guideline f...

Страница 3: ...ended use 10 2 3 Accessories 10 3 INSTALLATION AND FIRST USE 11 3 1 Unpacking the unit 11 3 1 1 Unpacking the front doors optional 12 3 2 Installation and positioning 12 3 2 1 Level the unit 13 3 2 2...

Страница 4: ...CC Cold Ambient EU 4 40 5 5 Cleaning interior bottom 30 5 6 Cleaning the condenser Self Contained Cold units 30 6 MALFUNCTIONS AND SERVICE 31 6 1 Replace the mains cord 31 7 TECHNICAL SPECIFICATIONS 3...

Страница 5: ...ion plate can be found on the outside of the machine and contains the following data Name of the supplier or the manufacturer Model Serial number Year of construction Voltage Frequency Power consumpti...

Страница 6: ...lways use the brakes on both front wheels when applicable 1 4 1 General The user of the unit will be fully responsible for abiding the locally prevailing safety rules and regulations The unit may be o...

Страница 7: ...herein R290 WARNING The propane refrigerant is highly flammable All safety precautions must be followed Keep all ventilation openings in the housing of the appliance or in the installation unobstructe...

Страница 8: ...devices or other components except piping between the motor compressor and the pressure relief device that could introduce a pressure drop The pressure relief device shall be mounted so that any refri...

Страница 9: ...your unit is included In case of malfunctions you can contact your dealer service agent Make sure you have the following data available Model Serial number This data can be found on the identification...

Страница 10: ...hanged from 1 C to 5 C The units can be connected to a fixed drainage system or an optional evaporation tray to evacuate condensation water One LED module per level provides for lighting of the produc...

Страница 11: ...unit In case of damage store the packing material and contact the transporter within fifteen working days after receiving the goods 3 1 Unpacking the unit 1 Unpack the unit as initiated on the unpacki...

Страница 12: ...Place the unit level on a sufficiently sturdy floor Keep the weight of the unit in mind Use a levelling instrument to level the unit by adjusting the unit s legs Be sure that the personnel have suffi...

Страница 13: ...5 mm 3 2 2 Mounting the plinths Place the rear plinth by attaching it to both rear adjustable legs using its two clamps Insert the pegs of both side plinths into the slots of the rear plinth Secure th...

Страница 14: ...and with the warning sticker above the handle Position the door over the bottom profile and place a plastic spacer between the bottom profile and the collar bearing Insert the retaining bolt from the...

Страница 15: ...rails for full serve models can be mounted on the air inlet grill and on the glass shelves Self serve models are supplied with price rails as standard Refer to installation manual 3 3 Drop in units Fo...

Страница 16: ...in the example below to change from a horizontal to an angled position Reverse the steps to change to a horizontal position from an angled position 1 Carefully lift the glass shelf out of its side su...

Страница 17: ...ture Please note that the rear level is supposed to be located at an equal or higher level than the LED armature 6 Place the glass shelf back onto its supports 3 5 Plateau Options The bottom presentat...

Страница 18: ...rts at the front and the back to the desired positions Place the plateaus back in the unit 3 6 First use Before starting to use the unit clean the inside thoroughly with mild detergent and water After...

Страница 19: ...ng on the unit Switch the cooling on by means of the temperature controller Let the unit cool for approx 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C The maxi...

Страница 20: ...d until you find the folder SET 3 Press SET to view the current setpoint value 4 Change the setpoint value using and within 15 seconds 5 To confirm the value press SET or or let a timeout occur 15 sec...

Страница 21: ...e unit In order to avoid temperature rise of the products store them in another cooling unit Switch the cooling and lighting off using the corresponding switches 4 1 2 1 Danfoss Temperature Controller...

Страница 22: ...ith the factory settings The indication will light when the cooling is active Adjusting the SET Temperature 1 Press Set until the display shows the current temperature setpoint flashing 2 Change the s...

Страница 23: ...estoring the gloss Weekly Glass panes Clean see section 5 4 Weekly Interior bottom Clean see section 5 5 Weekly Condenser Clean see section 5 6 Monthly 5 2 Daily Cleaning Clean the inside of the unit...

Страница 24: ...nd hold up the top glass pane throughout the process The air guide pane is laid up freely and somewhat flexible and can as such easily be removed from its support on the rear by applying a light amoun...

Страница 25: ...t leave it standing upright without being supported by both guide rails or holding it It is recommended to only move the pane to such an extent that the pane areas next to the support columns can be c...

Страница 26: ...orward do not drop whilst holding the top glass Lower the top glass back in place Clean the front glass Closing Lift and hold the top glass whilst closing the front glass A positive snap will make sur...

Страница 27: ...its climate Cleaning the sliding doors is therefore recommended during off hours Follow the following steps to access the inner sides of the sliding doors and the rear of the shelves for cleaning Slid...

Страница 28: ...until the innermost door s slot aligns with the guiding pin NOTE The outermost door should still be in its rotated position Turn the innermost door outwards as well to clean it Follow the above steps...

Страница 29: ...MCC Cold Ambient EU 29 40 Cleaning front door s optional Clean the outside of the front doors Open the front doors and clean the inside of the doors in the same way as the outside...

Страница 30: ...nser Self Contained Cold units WARNING Cleaning of the condenser must be performed by qualified persons and in a well ventilated environment Unscrew the condenser cover and open it WARNING Do not dama...

Страница 31: ...meter cupboard Are all the switches in the correct position Item Malfunction Possible action Unit Unit does not work Check the power supply Are all switches in the correct position Unit Display shows...

Страница 32: ...25 C 60 RH 3 25 C 60 RH 3 25 C 60 RH Minimum room floor area 8 13 m2 10 53 m2 12 92 m2 Refrigerant2 R290 R290 R290 Refrigerant charge 170 g 220 g 270 g Model MCC 90 3 C SS 90 4 C SS 120 3 C SS 120 4 C...

Страница 33: ...m2 Refrigerant4 R290 R290 R290 Refrigerant charge 170 g 220 g 270 g Model MCC 90 3 C FS 90 4 C FS 120 3 C FS 120 4 C FS 150 3 C FS 150 4 C FS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth...

Страница 34: ...CO2 R744 CO2 Circuit volume 1 58 dm3 2 22 dm3 2 83 dm3 Model MCC 90 3 C SS 90 4 C SS 120 3 C SS 120 4 C SS 150 3 C SS 150 4 C SS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth 750 mm 750 mm...

Страница 35: ...2 R744 CO2 Circuit volume 1 58 dm3 2 22 dm3 2 83 dm3 Model MCC 90 3 C FS 90 4 C FS 120 3 C FS 120 4 C FS 150 3 C FS 150 4 C FS Approved for EU EU EU Width 900 mm 1200 mm 1500 mm Depth 750 mm 750 mm 75...

Страница 36: ...rthed plug 16A 2 pole earthed plug 16A Length power cord approx 1 5 m 1 5 m 1 5 m 1 5 m Model MCC 60 3 A 60 4 A 90 3 A 90 4 A 120 3 A 120 4 A 150 3 A 150 4 A Approved for EU EU EU EU Width 600 mm 900...

Страница 37: ...MCC Cold Ambient EU 37 40 Notes...

Страница 38: ...MCC Cold Ambient EU 38 40 Notes...

Страница 39: ...MCC Cold Ambient EU 39 40 Notes...

Страница 40: ...Cold Ambient EU 40 40 Fri Jado B V Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel 31 0 76 50 85 400 Fri Jado Inc 1401 Davey Road Suite 100 Woodridge IL 60517 USA Tel 1 630 633 7950 www frijado...

Отзывы: