Bill of Materials 

 

1K x 4 
4K7 x 1 
10K x 4 
47K x 1 
100K x 3 
220K x 1 
 

All resistors ¼ watt 
metal film. 

 

22pF x 1

 

100nF x 2

 

10uF x 1 
47uF x 2

 

 
 
 

SEISMOGRAF PIC 
 

TL072 x 1 
 
BC547 x 1

 

 

1N4148 x 9

 

 

78L05 x 1

 

 

3mm red LED x 1 

 

14 pin IC socket x 1 
8 pin IC socket x 1

 

 

B100K x 3

 

 

3.5mm socket x 5 
 
Male header x 1

 

(cut to size) 
 

Female header x 1

 

(cut to size) 
 

Power header x 1 
 
Knob x 3 

 
Main PCB assembly 

1.

 

Solder the diode and all resistors 

2.

 

Solder all two IC sockets 

3.

 

Solder the non elecrolytic capacitors 

4.

 

Solder the 78L05 

 watch the polarity! 

5.

 

Solder the box power header. Make sure the notch lines up with the screenprint 
legend. If in doubt, have a look at a power cable, and make sure when inserted into 
the header the red stripe lines up with the -12V screenprint. 

6.

 

Solder all electrolytic capacitors. 

7.

 

Cut male headers to size and solder them into place. Make sure that they stick out of 
the bottom of the PCB. 

 

 