Bolt the metal shaft pots and the sockets to the panel using their nuts and washers. Pop the
knobs on the pots and the caps on the sliders. Looks nice huh?
Calibration
1.
Set all rotary pots fully anticlockwise
2.
Set all sliders to 5
3.
Plug a patch cable into
Little Melody’s CV Out
4.
Using a
(DMM), connect the black probe to the sleeve of the patch
cable (ie ground), connect the red probe to the tip of the patch cable (I find a couple
of
5.
Set the DMM to read DC voltage.
6.
Adjust the trimmer on the back of Little Melody until the DMM reads 5.00V.
All done! Go be generative!
RDH 24/07/20