Bolt the metal shaft pots and the sockets to the panel using their nuts and washers. Pop the 
knobs on the pots and the caps on the sliders. Looks nice huh? 

 
Calibration 
 

1.

 

Set all rotary pots fully anticlockwise 

2.

 

Set all sliders to 5 

3.

 

Plug a patch cable into 

Little Melody’s CV Out

 

4.

 

Using 

digital multimeter

 (DMM), connect the black probe to the sleeve of the patch 

cable (ie ground), connect the red probe to the tip of the patch cable (I find a couple 
of 

crocodiles

 can help here)  

5.

 

Set the DMM to read DC voltage. 

6.

 

Adjust the trimmer on the back of Little Melody until the DMM reads 5.00V. 

 
All done! Go be generative! 
 
 

 