background image

 

18 

 

 

With help of spirit level, check if both serve-overs are horizontal. 

 

All 3 connection slot positions in the figure. 

Содержание VEGA SPACE S HG

Страница 1: ...OPERATION MANUAL SERVE OVER VEGA SPACE S LG HG...

Страница 2: ...gerant circuit 10 2 7 Opening closing the doors 10 2 8 Recommended working conditions and ambient temperature 10 2 9 Purpose of use 11 3 UNPACKING 11 4 INSTALLATION 14 4 1 Requirements for installatio...

Страница 3: ...ER LIGHTING 26 11 ENERGY SAVING 27 12 DISPOSAL 27 13 STORAGE 27 14 TESTING 27 15 ACCESSORIES 27 16 TECHNICAL DATA 28 16 1 Electrical layouts 28 16 2 Failures and troubleshooting 28 17 MEANINGS OF SYMB...

Страница 4: ...turer information Manufacturer address FREOR LT UAB Katiliskiu St 92 LT 02212 Vilnius Lithuania T 370 5 232 9188 EN Made in Lithuania Customer Installation date Installation place Start of the product...

Страница 5: ...Fig 1 Fig 1 Example of sticker Intention of this document is to provide information about maintaining and operating of the serve over Vega Space S LG HG In accordance with the EU Directive the refrig...

Страница 6: ...6 1 2 Dimensions Fig 2 Dimensions of Vega Space S HG Fig 3 Dimensions of Vega Space S LG...

Страница 7: ...as been properly set up and installed and has no obvious defects Do not make any technical changes to the appliance Do not store any explosive substances such as aerosol containers with flammable prop...

Страница 8: ...not expose the unit to temperatures higher than 70 C during transportation and storage Avoid transmitting pulsations and vibrations to the unit Do not allow external forces to act on the appliance e...

Страница 9: ...setup and installation Protection from contact with liquid leaking refrigerant in the event of leakage in the refrigerant circuit Protection from low temperature during loading and cleaning For removi...

Страница 10: ...fault messages or damage to the appliance contact the maintenance service 2 7 Opening closing the doors Hand or other body parts may become caught on side of door hinge When opening closing the door...

Страница 11: ...dairy products delicacies ready made food snacks sandwiches green salad game salad with mayonnaise sauce cooked meat products eggs and their products sauces 4 C Household poultry minced meat and produ...

Страница 12: ...2 x 2 Size 17 15 min Use appropriate equipment for unit transportation refer to unit weight and dimension information Lift the serve over Remove pallet s screws Remove the pallet Screws M6x100 ISO 738...

Страница 13: ...13 Install the plastic legs Lower the serve over...

Страница 14: ...ly both depth and length and installed in the stable position Set up the unit only on the designated adjustable legs It is forbidden to install the unit close to any heating equipment or any HVAC elem...

Страница 15: ...15 4 2 Installation of Vega Space S LG HG X2 Size 17 32 PH2 Using the front and rear legs perform horizontal and vertical pre adjustment of the serve over The legs are adjustable up to 5 cm...

Страница 16: ...16 Apply the foam tape around perimeter of connection Apply silicone to seal the perimeter of connection...

Страница 17: ...17 Insert the guiding pins into indicated places Push the serve overs together...

Страница 18: ...18 With help of spirit level check if both serve overs are horizontal All 3 connection slot positions in the figure...

Страница 19: ...19 Front connection slot position Connection slots are fixed together with threaded pin M10x90 ISO 7985 Remove the back decoration...

Страница 20: ...20 Back connection slot position Connection slots are fixed together with threaded pin M10x90 ISO 7985 River the connection plate on the back of the connection Rivets D4 8x10...

Страница 21: ...21 Example of installed serve overs 5 INSTALLATION OF DUST COVERS X1 PH2 15 min Fix the front dust cover with self tapping screws D4 2x13...

Страница 22: ...22 Fix the rear dust covers and cover connector with self tapping screws D4 2x13 Fix the side dust covers with self tapping screws D4 2x13...

Страница 23: ...23 6 INSTALLATION OF LEG PANELS X1 PH2 15 min Attach the front panel to the leg Fix the sides of the panel with self tapping screws D4 2x13...

Страница 24: ...nnel Note the following before connecting the unit Applicable local electrical safety regulations The power supply voltage and frequency must match the specifications on the technical data sticker Do...

Страница 25: ...uce the temperature in the control Products must be uploaded into the cooled inner space of the serve over 9 2 Defrosting Warm ambient air can get into the serve over It is very likely when the showca...

Страница 26: ...aning Deep cleaning of the serve over must be performed once every 4 weeks The serve over must be cleaned and disinfected to eliminate pathogenic microorganisms Make sure that defrosting is in progres...

Страница 27: ...tions that dispose of certain types of materials 13 STORAGE If temporary storage and subsequent use of the serve over is expected during repair of the shopping premise or change location of the cabine...

Страница 28: ...serve over check the refrigerant amount and replacement of parts may only be carried out by a specialist qualified to work with F and OAM gases Only an electrician with the respective qualification ma...

Страница 29: ...ination of the freezing coil Damage of the tightness of the freezing coil Failure of the control valve TRV ERV Leakage of the refrigerant Call the refrigeration technician service department Defrostin...

Страница 30: ...elements can be operational Check switches Check the power network The compressor is out of order Refrigeration cycle malfunction Signals of the pressure sensors Fluctuations of the electrical network...

Страница 31: ...NINGS OF SYMBOLS Symbol Meaning Type Qualified specialist Work clothing Protective gloves Brittle surfaces Wrench Sizes 10 13 17 32 Screwdriver PH2 Rubber hammer 1 Protective goggles Silicone pistol 1...

Страница 32: ...ufacturer of the commercial refrigeration equipment Katiliskiu St 92 LT 02212 Vilnius Lithuania T 370 5 232 9188 E sales freor com www freor com DOM 1CA0X 00000E_v2 0 FREOR LT is not affiliated with C...

Отзывы: