![freor PLUTON SPACE Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/freor/pluton-space/pluton-space_operation-manual_2331497035.webp)
35
Potential reasons
Error signal
Potential reason
Troubleshooting
High temperature in the
internal space of the semi
vertical
Power supply failure (the
system does not receive
power supply).
Check electrical
installations, network and
fuses.
The temperature of the
uploaded products is
higher than the
temperature in the internal
space of the semi vertical.
Remove warm products
from the cabinet and
freeze them up to the
necessary temperature in
the freezer compartments.
Contamination of the
freezing coil;
Damage of the tightness of
the freezing coil;
Failure of the control valve
(TRV / ERV);
Leakage of the refrigerant.
Call the refrigeration
technician / service
department.
Defrosting disorders;
Failure of defrosting
heating elements;
Disorder of the
electromagnetic valve
functionality;
Failure of the defrosting
clock;
Failure of the control
system;
Icing of the evaporator;
High load in the semi
vertical, unsuitable amount
of products.
Check loads of the shelves
and air circulation flows.
Reset factory settings in
the control.
Failure of the fans.
Call the manufacturer or
qualified representative.
Содержание PLUTON SPACE
Страница 1: ...OPERATION MANUAL SEMI VERTICAL PLUTON SPACE...
Страница 7: ...7 Fig 5 Dimensions of Pluton Space Island 6 plug in...
Страница 20: ...20 Using a rubber hammer attach the rubber bumper...
Страница 27: ...27 Unscrew the screws of the compressor cover Remove the compressor cover...
Страница 38: ...38 Date Work Name...
Страница 39: ...39 Date Work Name...