background image

 

 

 

 

999367 – Revision B 

 

P a g e

 | 

18 of 40

 

 

Size

 

Mackworth Sling Range - Product Material and Code

 

Polyester Solid  Polyester Mesh 

Parasilk 

Quilted  Supersoft Spacer 

Mackworth Oak

 

Small 

1201OK7500 

1201OK8500 

1201OK3500  1201OK5500 

1201OK4500 

Medium 

1201OK7400 

1201OK8400 

1201OK3400  1201OK5400 

1201OK4400 

Large 

1201OK7300 

1201OK8300 

1201OK3300  1201OK5300 

1201OK4300 

XL 

1201OK7200 

1201OK8200 

1201OK3200  1201OK5200 

1201OK4200 

XXL 

1201OK7100 

1201OK8100 

1201OK3100  1201OK5100 

1201OK4100 

XXXL 

1201OK7000 

1201OK8000 

1201OK3000  1201OK5000 

1201OK4000 

Mackworth Oak with head support

 

Small 

1201OK7520 

1201OK8520 

1201OK3520  1201OK5520 

1201OK4520 

Medium 

1201OK7420 

1201OK8420 

1201OK3420  1201OK5420 

1201OK4420 

Large 

1201OK7320 

1201OK8320 

1201OK3320  1201OK5320 

1201OK4320 

XL 

1201OK7220 

1201OK8220 

1201OK3220  1201OK5220 

1201OK4220 

XXL 

1201OK7120 

1201OK8120 

1201OK3120  1201OK5120 

1201OK4120 

XXXL 

1201OK7020 

1201OK8020 

1201OK3020  1201OK5020 

1201OK4020 

Mackworth Yew

 

Small 

1201YW7500 

1201YW8500 

1201YW3500 

n/a 

1201YW4500 

Medium 

1201YW7400 

1201YW8400 

1201YW3400 

n/a 

1201YW4400 

Large 

1201YW7300 

1201YW8300 

1201YW3300 

n/a 

1201YW4300 

XL 

1201YW7200 

1201YW8200 

1201YW3200 

n/a 

1201YW4200 

XXL 

1201YW7100 

1201YW8100 

1201YW3100 

n/a 

1201YW4100 

XXXL 

1201YW7000 

1201YW8000 

1201YW3000 

n/a 

1201YW4000 

Mackworth Yew with head support

 

Small 

1201YW7520 

1201YW8520 

1201YW3520 

n/a 

1201YW4520 

Medium 

1201YW7420 

1201YW8420 

1201YW3420 

n/a 

1201YW4420 

Large 

1201YW7320 

1201YW8320 

1201YW3320 

n/a 

1201YW4320 

XL 

1201YW7220 

1201YW8220 

1201YW3220 

n/a 

1201YW4220 

XXL 

1201YW7120 

1201YW8120 

1201YW3120 

n/a 

1201YW4120 

XXXL 

1201YW7020 

1201YW8020 

1201YW3020 

n/a 

1201YW4020 

Mackworth Hazel

 

Small 

1201HZ7500 

1201HZ8500 

1201HZ3500  1201HZ5500 

1201HZ4500 

Medium 

1201HZ7400 

1201HZ8500 

1201HZ3400  1201HZ5400 

1201HZ4400 

Large 

1201HZ7300 

1201HZ8300 

1201HZ3300  1201HZ5300 

1201HZ4300 

XL 

1201HZ7200 

1201HZ8200 

1201HZ3200  1201HZ5200 

1201HZ4200 

XXL 

1201HZ7100 

1201HZ8100 

1201HZ3100  1201HZ5100 

1201HZ4100 

XXXL 

1201HZ7000 

1201HZ8000 

1201HZ3000  1201HZ5000 

1201HZ4000 

Mackworth Hazel with head support

 

Small 

1201HZ7520 

1201HZ8520 

1201HZ3520  1201HZ5520 

1201HZ4520 

Medium 

1201HZ7420 

1201HZ8520 

1201HZ3420  1201HZ5420 

1201HZ4420 

Large 

1201HZ7320 

1201HZ8320 

1201HZ3320  1201HZ5320 

1201HZ4320 

XL 

1201HZ7220 

1201HZ8220 

1201HZ3220  1201HZ5220 

1201HZ4220 

XXL 

1201HZ7120 

1201HZ8120 

1201HZ3120  1201HZ5120 

1201HZ4120 

XXXL 

1201HZ7020 

1201HZ8020 

1201HZ3020  1201HZ5020 

1201HZ4020 

Mackworth Willow

 

Small 

1201WL7500 

This sling is made up of a single quilted material backed with solid 

polyester material. 

Medium 

1201WL7400 

Large 

1201WL7300 

Содержание S180E Mobile Hoist

Страница 1: ...Doc No 999367 Revision of document B Revision Date 10 06 21 S180E Mobile Hoist User Manual...

Страница 2: ...Hoist Assembly 10 3 4 Electrical Connections 11 Final Inspection 11 Operating instructions 12 5 1 Manoeuvring the Hoist 12 5 2 Raising and Lowering 12 5 3 Open Close Mobile Hoist Legs 12 5 4 Emergency...

Страница 3: ...E Mobile Hoist Dimensions 26 7 2 Specifications 27 7 3 Electrical Specifications 27 7 4 Standards Applied 27 Environmental Storage and Operating Conditions 28 8 1 Normal Operating Conditions 28 8 2 Sh...

Страница 4: ...nufacturer and to your national authority Store this manual with the documents included with the Mobile Hoist and sling s Contents of this manual are subject to change without prior written notice Ens...

Страница 5: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Страница 6: ...the operation of the aid is undertaken by a trained carer A risk assessment must be performed before using any other manufactured slings or Mobile Hoist to ensure safe use can be established The Freew...

Страница 7: ...with Between Hoist Spreader Bar and Body Support Unit the lowest maximum load shall always be used You may need to seek specialist advice on how to assist some people with specific moving and handling...

Страница 8: ...ceived all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Description Item Description 1 Boom 6 Handle 2 Mast 7 Front Cast...

Страница 9: ...ance of the Hoist and to avoid unnecessary damage or injuries to people within the area of the Mobile Hoist The environment in which the Mobile Hoist is situated in whilst carrying out a transfer is r...

Страница 10: ...ked castors are locked D Remove the Star Handle and bolt from the top of the base as shown in Fig 3 E Ensure all cables are clear from entrapment while fitting the base and mast together As shown in F...

Страница 11: ...cables are located and secure Ensure the red emergency stop button on the control box is deactivated Rotate clockwise to release if required Refer to section 5 4 for guidance Press the up button on t...

Страница 12: ...r castors can be braked for rotation by applying a single brake lateral movement and parking To apply the brake press the brake pedal down with your foot as shown in Fig 13 To release the brake press...

Страница 13: ...vider 5 5 2 Electrical Emergency Lowering The Mobile Hoist Boom can be raised and lowered by pushing the emergency lifting and lowering buttons on the control box with a suitable object such as a pen...

Страница 14: ...save the battery When the service indicator lights up the system will still be functional Battery State Indication Comment 1 The battery is OK no need for charging 100 50 the third LED is green 2 The...

Страница 15: ...rged state You cannot overcharge the battery pack if left for longer periods of time D To return the Hoist to use switch off the mains supply Remove the plug from the socket and clip onto the Mast E T...

Страница 16: ...purpose if the symbol is to inform the user that it is not possible to use the lift when it is plugged into the mains Short Circuit If there is a short circuit the control box will show the short circ...

Страница 17: ...locking mechanism lift the loop out of the hook and release the locking mechanism The same process of attaching and detaching the Sling is relevant for the QRS Quick Release System Carry Bar 5 9 2 Com...

Страница 18: ...1YW8100 1201YW3100 n a 1201YW4100 XXXL 1201YW7000 1201YW8000 1201YW3000 n a 1201YW4000 Mackworth Yew with head support Small 1201YW7520 1201YW8520 1201YW3520 n a 1201YW4520 Medium 1201YW7420 1201YW842...

Страница 19: ...0 1201BC3120 1201BC5120 1201BC4120 XXXL 1201BC7020 1201BC8020 1201BC3020 1201BC5020 1201BC4020 Mackworth Pine Small 1201PN7500 1201PN8500 1201PN3500 1201PN5500 1201PN4500 Medium 1201PN7400 1201PN8400...

Страница 20: ...ML CA400SL CA400PAL X Large CA400PXL CA400MXL CA400SXL CA400PAXL CA500 Toilet Access P1 CA500PP1 CA500MP1 CA500SP1 CA500PAP1 P2 CA500PP2 CA500MP2 CA500SP2 CA500PAP2 P3 CA500PP3 CA500MP3 CA500SP3 CA500...

Страница 21: ...CA503SP1 CA503PAP1 P2 CA503PP2 CA503MP2 CA503SP2 CA503PAP2 P3 CA503PP3 CA503MP3 CA503SP3 CA503PAP3 P4 CA503PP4 CA503MP4 CA503SP4 CA503PAP4 P5 CA503PP5 CA503MP5 CA503SP5 CA503PAP5 X Small CA503PXS CA50...

Страница 22: ...A701PP2 CA701MP2 CA701SP2 CA701PAP2 P3 CA701PP3 CA701MP3 CA701SP3 CA701PAP3 P4 CA701PP4 CA701MP4 CA701SP4 CA701PAP4 P5 CA701PP5 CA701MP5 CA701SP5 CA701PAP5 X Small CA701PXS CA701MXS CA701SXS CA701PAXS...

Страница 23: ...SPAP3 P4 CA702HSPP4 CA702HSMP4 CA702HSSP4 CA702HSPAP4 P5 CA702HSPP5 CA702HSMP5 CA702HSSP5 CA702HSPAP5 X Small CA702HSPXS CA702HSMXS CA702HSSXS CA702HSPAXS Small CA702HSPS CA702HSMS CA702HSSS CA702HSPA...

Страница 24: ...the locking mechanism into the hook by pressing down on the tab Figure 30 and 31 2 With the carry bar positioned sideways along the length of the bar move the pin at the top of the carry bar into the...

Страница 25: ...procedure Attach 1 Grab Hold of the Battery from the top position as shown in figure 35 and place your fingers onto the latch 2 Press the latch to release the Battery and lift the Battery from its fi...

Страница 26: ...999367 Revision B P a g e 26 of 40 Technical Specification 7 1 Freeway S180E Mobile Hoist Dimensions All dimensions below are shown in millimetres Figure 38 Figure 39...

Страница 27: ...0 VDC 0 8A Electric Shock Protection Charger Class II Lift internal power source Degree of shock protection Type B Lift internal power source Duty cycle 10 Use 90 Rest 90 seconds use 810 seconds rest...

Страница 28: ...ntended use safely the Hoist must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure including local laws and being environmentally...

Страница 29: ...eaks Hoist doesn t lift Check if the Hoist is plugged into Charge Hoist will not raise and lower while on charge Check that the Lift Actuator to Control Box cable is connected properly between the two...

Страница 30: ...cumented each service in the Service Log at the back of this User Manual When the Mobile Hoist is serviced the 6 month service checklist must be completed for the Freeway S180E Mobile Hoist Service Ma...

Страница 31: ...r than the regular charging as detailed in the charging instructions Emergency Stop Button Check the emergency stop button functionality Manual Emergency Lower Check the manual emergency lower functio...

Страница 32: ...before the cleaning process Application is through a clean damp cloth applied to wipe the device down Use in the following dilutions to ensure an effective clean Actichlor dissolvable chlorine tablets...

Страница 33: ...y precautions when using this cleaning agent Advice on Safe Handling Avoid contact with skin and eyes Do not breathe dust fumes gas mist vapours spray Use only with adequate ventilation Wash hands tho...

Страница 34: ...rchased the equipment from Prism Medical UK In no event shall Prism Medical UK incur liability for any consequential or unforeseeable losses 3 This equipment guarantee shall be void if the equipment i...

Страница 35: ...999367 Revision B P a g e 35 of 40 Service Record History Complete this section after each service repair inspection and or maintenance...

Страница 36: ...999367 Revision B P a g e 36 of 40...

Страница 37: ...999367 Revision B P a g e 37 of 40...

Страница 38: ...999367 Revision B P a g e 38 of 40...

Страница 39: ...999367 Revision B P a g e 39 of 40 User notes...

Страница 40: ...or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Manufacturer contact detail...

Отзывы: