Installation Manual 

 

 

 

 

 
 
 
                                                                                

FHWFC 5000 Series 

Version 2010.09 

 

 

Содержание FHWFC 5000 Series

Страница 1: ..._________________ _______________________________________________________________________________ Free Hot Water 2146 Bering Dr San Jose CA 95131 Tel 408 218 3660 Fax 408 872 4142 www FreeHotWater net...

Страница 2: ...nformation 3 Transport note 4 Assembly instructions Collector 5 Overview of tools 6 Overview of materials 7 Attachment points 8 Mounting parallel roof bracket attachment system 9 Technical data Collec...

Страница 3: ...Page 3...

Страница 4: ...Page 4 Attention Do not lift the collectors by the connections and or the screw threads...

Страница 5: ...mstances at the place of installation foehn wind air jets or eddy formation etc which can lead to increased loads The collector is designed for wind loads of 150 km h and snow loads of 1 25kN m2 As a...

Страница 6: ...ion bends or flexible members inserted in the links IMPORTANT check the pump design When tightening the union nuts always balance counter the torque with a pipe wrench or another spanner to prevent da...

Страница 7: ...Page 7 Tools Needed Brackets hooks bolts etc _______________________________________________________________________________...

Страница 8: ...Pressure 10 bar Net Absorber Area m2 1 85 Recommended Working Pressure 3 bar Dimensions mm 2018 x 1018 x 102 Recommended Flow Rate 10 40 l h m2 Absorber Dimension mm 1950 x 950 x 0 2 Weight Empty kg 3...

Страница 9: ...Page 9 Recommend Anchor Points for the FHW FC5000 series...

Страница 10: ...m h Collector Area m2 6 8 12 24 Pipe Diameter Copper mm 10 12 15 18 22 Pipe Diameter STS corrugated DN 16 DN 20 Pressure loss per collector for anti freeze FS water mixture 40 60 at a thermal conduct...

Страница 11: ...l system should be filled and commissioned within one week of installation because heat build up in the collector array can damage the flat gaskets in empty systems If this is not possible the flat ga...

Страница 12: ...d when commissioning the system after filling the collectors 4 weeks after commissioning when necessary e g if there are malfunctions Warning Risk of scalding due to steam and hot heat transfer fluid...

Страница 13: ...o avoid over pressure in the solar circuit torque in Nm is available in certain countries from the data sheet attached to the collector Collector angle It is recommended to keep the solar collector an...

Страница 14: ...the mounting bracket not both holes fig 1 1 Note for collector model 7000 upper and lower mounting bracket should be 78 apart measured from top of top bracket to bottom of bottom bracket Note both the...

Страница 15: ...he hose through the hole 7 Begin mounting bracket installation with bottom bracket Mark a straight chalk line between the 2 bottom bracket mounting points Fig 1 4 8 For composition shingle roof DO NOT...

Страница 16: ...ll bit 11 FOR ONE BOTTOM BRACKET ONLY apply Solarflex in bracket screw holes on roof surface where bracket will be placed and on bracket surface that will be facing down Fasten first bottom bracket on...

Страница 17: ...han one collector cut flex hose or copper pipe in length necessary to connect collectors On all plumbing connections use Anti Leak part FHWM AA 72050 21 Connect collectors with each other if installin...

Страница 18: ...Page 18 Fig 1 91...

Страница 19: ...roof to the desired mounting points and mark the points where the collector mounting frame fig 2 2 will be installed fig 2 1 Fig 2 1 Fig 2 2 3 Follow the plumbing connections Blue for Supply and Red...

Страница 20: ...the frame kit as per the illustrated in fig 2 4 2 If you have more than one bank of 3 collectors you will need to use the FHW expansion band as illustrated in fig 2 5 3 At the end of every bank pleas...

Страница 21: ...ys use the respective assembly instructions supplied with the collectors Figures and illustrations used Due to the possibility of setting and printing errors and to the need for continuous technical c...