121
Name
Mnemonic
Bits
Value (hex)
Note
Emergency
E
1
80
Protected
P
1
40
Encryption is not supported
Duplex
D
1
20
Mode
M
1
10
Reserved
R
1
08
0 is specified
Priority Level
3
01 to 07
Highest to lowest
Table 2.2.7.3.1.3-4. P25 Service Options
Note: Service options are combined by adding their respective values. Example: The Emergency, Duplex,
and Highest Priority Level options combined have a value of A1.
Constellation Plot (Display Zone selection)
This selection displays the EVM measurement and a graph showing the symbol constellation on the
complex I/Q plane. The display provides a visual representation of overall transmitter operation – see
Figure 2.2.7.3.1.3-5, when Monitor Modulation Type is complex, e.g. LSM or WCQPSK. The
measurement is done at the optimal symbol times and positions to exclude adverse effects of frequency
error and residual carrier. The Display Mode setting configures the amount of information on the graph.
Figure 2.2.7.3.1.3-5 Constellation Plot (Symbols)