Know Your Environment

Working at a fueling station can present many dangers. It is a potentially dangerous environment of 
electricity, flammable fuels, vapors, and interaction with the general public. Only trained and 
knowledgeable individuals should perform service on the equipment. It is important to your safety and the 
safety of others to follow proper procedures.

Emergency Shut Off (ESO)

Know how to turn OFF power to all the fueling equipment by locating the ESO switch and circuit breakers. 
You must know how to shut off all fuel flow and electricity in an emergency.

Follow the Regulations

Information is available at Occupational Safety and Hazard Association (OSHA), National Fire Protection 
Association (NFPA) 30A; Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 70; 
National Electrical Code (NEC), as well as other national, state and local entities. All applicable codes 
must be followed to maintain safe installation, service, use and operation of the equipment.

LOTO (Lockout/Tagout)

Always make sure ALL power to the dispenser is turned OFF before servicing the 
dispenser. Follow OSHA Standard 29 CFR 1910.147 The Control of Hazardous Energy (Lockout/Tagout).

No Sparks - No Smoking

Sparks from power tools, burning cigarettes, static electricity, vehicles and other sources can ignite fuels 
and their vapors. Ensure that you use safe and established practices while working with electrical devices 
and equipment.

Wear Proper PPE

Check with your company, customers and the job/site specifics to determine what types of personal 
protective equipment are appropriate. Always wear the proper PPE to prevent injuries and save lives.

Barricade Your Work Area

One of the dangers of working at an active retail fueling station is the potential impact of customers and the 
general public. It is important to properly establish your work area by barricading, to reduce the potential 
of vehicles or customers from entering the work area. The use of barricades is both for the protection of 
workers and protection of the general public/customers.

Read the Manual(s)

Knowledge of all related manufacturer procedures, manuals and documents is important. Follow the 
Recommended Practices of The American Petroleum Institute (API). Understand the specific procedures 
before starting work. If you do not understand a procedure, call Freedom Electronics at 770-792-8888.

Notify Site

On arrival identify yourself to the site manager and inform them of the work you will be performing.

3

FE-22 Printer

Freedom Electronics: FE-22 Install

Содержание Wayne Ovation FE-22

Страница 1: ...dom Electronics FE 22 Printer Rev 4 3 2022 Kit FE 22 New Description FE 22 Install Model Ovation 1 Dispenser This kit will upgrade printers on Ovation 1 dispensers only The Ovation 2 dispensers are currently not supported 1 FE 22 Printer Freedom Electronics FE 22 Install ...

Страница 2: ... FW00011 Printer Door Blanking Panel Overlay 1 FW00013 Blanking Panel Gasket 1 91090A101 Blanking Panel Washers 6 FE 22 NFC Kit Contactless Manufacturer Part Description Quantity FW00006 Contactless Panel 1 FW00012 Contactless Panel Overlay 1 FC00012 Contactless Reader Extension Cable 1 FW00013 Blanking Panel Gasket 1 91090A101 Blanking Panel Washers 6 97975A205 Blanking Panels Screws 6 FE 22 Secu...

Страница 3: ...azardous Energy Lockout Tagout No Sparks No Smoking Sparks from power tools burning cigarettes static electricity vehicles and other sources can ignite fuels and their vapors Ensure that you use safe and established practices while working with electrical devices and equipment Wear Proper PPE Check with your company customers and the job site specifics to determine what types of personal protectiv...

Страница 4: ... the two locks on the door 4 Keep the door wide open using the door hinge 5 If the dispenser has a contactless reader on the cash acceptor panel as shown to the right then disconnect the contactless reader cable from iX board 6 Remove the cash acceptor panel by removing the 6 screws marked in yellow 4 FE 22 Printer Freedom Electronics FE 22 Install ...

Страница 5: ... onto the dispenser door in place of the cash acceptor panel using the provided screws 9 Install the Printer Door Overlay FW00008 and Printer Door Frame Overlay FW00009 10 Disconnect and remove the OEM printer power cable 11 Disconnect and remove the OEM printer data cable 5 FE 22 Printer Freedom Electronics FE 22 Install Printer power cables connections at distribution board ...

Страница 6: ... Power Input Cable FC00005 to the Wayne distribution board 16 Connect the Extended Data Input Cable FC00004 to the Wayne SPM 17 Connect the Power and Data cables to the FE 22 printer as shown 18 Route the grounding cable along with the other cables and attach it to a grounding point in the dispenser 19 Secure the cables with zip ties 6 FE 22 Power Serial connections Data Power FE 22 Printer Freedo...

Страница 7: ...nel and install it onto the Contactless Panel FW00006 24 Install the contactless panel to the dispenser in the printer opening using the 6 washers and 6 screws provided 25 Install the provided Contactless Panel Overlay FW00012 26 Connect the Contactless Reader Extension Cable FC00012 to the reader and reconnect it to the iX board 7 Contactless panel mounted on OEM printer opening Switching contact...

Страница 8: ...ng it straight out 31 Press the diagnostic button on the FE 22 printer and verify proper operation 32 Close the dispenser door and lock it 33 Run a transaction select yes for receipt and verify a receipt is printed 34 Open the printer door and make sure there are not any obstructions and close the printer door when done 35 Finally make sure that there are no errors displayed on the POS system insi...

Страница 9: ... for FE 22 printer Wayne Ovation dispenser with SPM JP1 JP4 at RS232 position JP5 JP7 at RS232 position Wayne dispenser with QCAT JP1 JP4 at TTL position JP5 JP7 at RS232 position 9 TTL RS232 FE 22 Printer Freedom Electronics FE 22 Install ...