Free The Tone PA-1QB Скачать руководство пользователя страница 4

6

7

The PA-1QG/PA-1QB can save or recall preset contents to/from a personal computer. For connection 
and setup procedures, please confirm with the product or support page of the Free The Tone website.

The PA-1QG/PA-1QB can update its firmware. For the latest firmware or connection and setup proce-
dures, please confirm with the product or support page of the Free The Tone website.

1.

  Turn on the power to the unit while holding down the 

 cursor key switch and 

PRESET SELECT

 switch.

2.

 The 

LEVEL

 display shows “

1 n t

”.

3.

  Press the 

PARAMETER

 encoder to execute the initialization.

4.

 The 

PRESET

 display counts up from 01 to 99.

5.

 The 

LEVEL

 display shows the firmware version number.

6.

  All of the presets are returned to their factory default settings and usual operation resumes.

NOTE

This operation clears all of the presets and resets all of the settings to the default status as shipped from the factory.

Recalling a Preset

Transmitting Data to/from an External Device

Updating Firmware

Initializing

Setting Up MIDI Signals

The PA-1QG/PA-1QB can use up to 99 presets that can be recalled in various ways.

To switch among the first four presets:

1.

  Press the 

ON/OFF

 switch to turn on the LED above it.

2.

  Press the 

PRESET SELECT

 switch to switch the presets.

NOTE

Each press of the 

PRESET SELECT

 switch changes the presets as follows: PRESET 1 

 PRESET 2 

 PRESET 3 

 PRESET 4 

 

PRESET 1, ...

To switch among the 99 presets:

1.

  Press the 

ON/OFF

 switch to turn on the LED above it.

2.

  Press the 

PRESET

 switch to flash the 

PRESET

 display.

3.

  Turn the 

PARAMETER

 encoder to show the preset to be recalled.

4.

  Press the 

PARAMETER

 encoder to recall the selected preset.

To switch presets via MIDI:

1.

  Connect an external MIDI controller to the 

MIDI IN

 terminal on the PA-1QG/PA-1QB’s rear panel.

2.

  Press the PA-1QG/PA-1QB’s 

ON/OFF

 switch to illuminate the LED above it.

3.

  From the external MIDI controller, send the MIDI program change number corresponding to the preset to be 

recalled.

NOTE

Be sure to set the same MIDI program change number on the sending device’s MIDI channel and the PA-1QG/PA-1QB’s MIDI channel.

Setting up MIDI Receiving Channel 

 P.6

When the PA-1QG/PA-1QB receives a MIDI program change number 001–004, the corresponding LED 1–4 above the 

PRESET 

SELECT

 switch illuminates and the 

PRESET

 display shows the corresponding preset number (01–04). If a MIDI program change 

number 005 or later is received, then the LEDs 1–4 above the 

PRESET SELECT

 switch will not illuminate but the 

PRESET

 display 

shows the corresponding preset number (05–99).

The PA-1QG/PA-1QB can receive MIDI signals sent from an external controller to switch presets and edit 
parameters.

To setup a MIDI receiving channel:

1.

  Turn on the power to the PA-1QG/PA-1QB while holding down the 

PRESET SELECT

 switch.

2.

 The 

PRESET

 display shows “

ch

”.

3.

 The 

LEVEL

 display shows the number of the MIDI receiving channel.

4.

  Turn the 

PARAMETER

 encoder to show the desired MIDI receiving channel.

5.

  Press the 

PARAMETER

 encoder to confirm the selected MIDI receiving channel.

NOTE

User editable parameters: ALL (Omni mode), 1–16 (MIDI receiving channel), OFF

Отзывы: