- 20 -
Setting by input AI1
2
:
AI2
Setting by input AI2
3
:
Communication given
Setting by the communication
4: HI pulse input
Setting by HI pulse input
H00.08
Feedforward frequency
digital given
0.0%~100.0%
100.0%
△
When H00.07 set to be 0, H00.08 set the value of Feedforward frequency
H00.09
Roll diameter coefficient
K upper limit
0.0%~600.0%
Winding:300.0
%
Unwinding:100.
0%
Straight
line:300.0%
△
The upper limit value of roll diameter coefficient K
H00.10
Roll diameter coefficient
K starting value
0.0%~ feedforward gain limit
Winding:40.0%
Unwinding:0.0
%
Straight line:
300.0%
△
The initial value when inverter start roll diameter coefficient K
H00.11
Smooth starting time
0.0~120.0s
收卷
:1.0s
放卷
:0.0s
直进式
:0.0s
△
In smooth starting time, PI does not calculate, inverter start to accelerate and search a suitable
roll diameter coefficient K according to deviation E because of the effect of feedforward, then deviation
E tends to be 0. When reach smooth starting time, PI start to adjust so as to avoid bigger deviation and
vibrate, and accelerate to reach the target value.
Note
: When balance bar position is over the centre position in smooth starting time, inverter will exit
PI soft start state automatically then entry PI adjustment.
H00.12
Smooth start K increment
per second
0.00~100.00%
0.60%
△
In smooth starting time, roll diameter coefficient adjust the increment per second according to
balance bar, bigger value indicate faster adjustment
H00.13
Roll diameter coefficient
range 1
0.00~100.00%
2.0%
△
H00.14
Roll diameter coefficient
range 2
0.0%~Roll diameter coefficient
range 2
10.0%
△
H00.15
Roll diameter coefficient
range 3
Roll diameter coefficient range
1~3
20.0%
△
H00.16
Roll diameter coefficient
range 4
Roll diameter coefficient range
2~4
30.0%
△
H00.17
Roll diameter coefficient
range 5
Roll diameter coefficient range
3~5
35.0%
△
H00.18
Roll diameter coefficient
K increment 1
Roll diameter coefficient range
4~100.0%
0.05%
△
H00.19
Roll diameter coefficient
K increment 2
0.00~100.00%
0.08%
△
H00.20
Roll diameter coefficient
K increment 3
0.00~100.00%
0.50%
△
H00.21
Roll diameter coefficient
K increment 4
0.00~100.00%
1.00%
△
H00.22
Roll diameter coefficient
K increment 5
0.00~100.00%
6.00%
△
Roll diameter coefficient will be adjusted automatically corresponding to the incremental according
to the scope of balance bar. No adjustment below range 1, adjust with increment 1
Between range 1 and 2, adjust with increment 2 between range 2 and 3, adjust with increment 3