PRO-S Rev1104
35
Figure 13. Navistar and Detroit Diesel (Series 40) PRO-S 4 Wiring
(Sheet 2 of 2)
Navistar and Detroit Diesel (Series 40) Harness
Connections
Interface Information
The ECM must be programmed for a remote throttle input. Set PTO REMOTE
PEDAL to 1. (This will enable the remote throttle input.)
The VARIABLE PTO ENABLE input has to be at 12 VDC to activate the
remote throttle. (12 VDC can be picked up from the interlock circuit.)
EST
Connector
ATA (–)
J1587
Datalink (See
Sheet 1)
Black Wire
Red Wire
Pin A
ATA (+)
Pin B
REMOTE THROTTLE INPUT
RESCM
VARIABLE PTO ENABLE
+5VDC REFERENCE
REMOTE THROTTLE
GROUND
11
19
14
17
Engine
Control
(See Sheet 1)
White Wire
Black Wire
Red Wire
Note: 12 when
the pump interlock
circuit is engaged.
Note: 2004 and newer model engines with
code 12VXY and the Remote Engine Speed
Controller Module (RESCM) installed.
99F
97DD
97HM
97CC
REMOTE THROTTLE INPUT
NAVPAK ECM
VARIABLE PTO ENABLE
+5VDC REFERENCE
REMOTE THROTTLE
GROUND
5
36
6
30
Engine
Control
(See Sheet 1)
White Wire
Black Wire
Red Wire
Note: 12 when
the pump interlock
circuit is engaged.