AMA200 Rev150720
13
CODE
FEATURE
OPTION
312
ID Number
0 to 99
313
Module Function
Pri, SLA
314
Unit of Measure/
Full Bottle Pressure
PSI, kPa, BAR
0 to 8000
316
Low Air Warning
20 to 99 (%)
330
Audible Alarm
00 to 99
340
CAN Terminator
On, Off
E201
Datalink Failure
Check Datalink and Programming
E202
Invalid Program Code Entered Re-Enter Code
E208
Memory Failure
Contact Factory
E212
Pressure Sensor
Voltage Out of Range
Table 1. Program Code Quick Reference
Notes:
- Refer to Program Code Descriptions for detailed information.
- The time-out feature returns the program to normal operation in five
seconds if input is not detected.
- When a valid code has been entered and a programed value or option is
shown in the display, the time-out feature is disabled.