Troubleshooting: No Ionisation
Check mains supply and fuse on power unit. Replace fuse if necessary - see fuse details below.
The power unit has a current limitation of 5mA which ensures the safety of the system. If there is a
short on one of the bars it will try to draw more current than 5mA. When this happens the power unit
will shut down. Disconnect one bar at a time to discover which bar is causing the problem.
Health & Safety
The ozone generated by this product is less than 0.1ppm and within internationally accepted limits
Please note, when handling and cleaning, that the emitter pins are sharp and care is needed.
Spare Parts
Fuse in Power Unit: 20 x 5mm, value 400mA for 230V, or 800mA for 115V rated to 1500A.
Fuseholder: Bulgin
FX0462
On/off Switch:
Arcoelectric C1353ALGNE
Declaration of Conformity
We declare that this equipment conforms to the following EC Directives:
94/9/EC (Equipment intended for use in potentially explosive atmosphere (ATEX) directive)
•
EN60079-0
•
EN60079-18
89/336/EEC ( Electromagnetic Compatibility (EMC) Directive)
•
EN61000-6-3
•
EN55011-1-B
72/23/EEC (Low Voltage Equipment Directive)
•
EN60204-1
For further information, please contact the manufacturer:
Instructions/Booklet/EX1250
iss.11
9
Содержание EX1250
Страница 1: ...1250 EXHP ...
Страница 3: ...EX1250 Static Eliminator Bar Operating Instructions Instructions Booklet EX1250 iss 11 3 ...
Страница 10: ......
Страница 18: ......
Страница 19: ...EX1250 Antistatikstab und EXHP Netzteil Betriebsanleitung Instructions Booklet EX1250 iss 11 19 ...
Страница 26: ......