Franklin Pump Systems S - J Series Скачать руководство пользователя страница 4

3

PARTS FOR MODEL J, JCM, S, and SKM

8

7a

7

3

6

5

4

2

1

Figure No.

Part No.

Description

1

9010-1197-R

Motor 3/4HP 115/1/60 48Y Frame

9010-1247-R

Motor 1HP 115/1/60 48Y Frame

9010-0710-R

Motor 1-1/2HP 115/1/60 48Y Frame

2

02-1308-05-RKIT

J Bracket Kit (incl. #7 3-10 butt & #8 1/4-14 x 1-1/8 fasteners)

02-1309-04-R

JCM & SKM Bracket (eff. 2/1/94) 1/4-14 Thrd, 2-1/2 butt

02-1613-05-R

JCM & SKM Bracket (eff. prior 2/1/94) 1/4-20 Thrd, 2-1/2 butt

3

47-0357-46-R

O-ring 5-1/2 x 5-7/8 x 3/16

4

10-0002-06-R

5/8 Mechanical Seal

5

05-3862-06-R

Impeller S7J, S7K #11343 3.45D

05-3863-05-R

Impeller S1J, S1K #11343 3.73D

05-3864-04-R

Impeller S15J, S15K #11343 4.10D

05-3865-03-R

Impeller S2J, S2K #11304 4.22D

6

10-1462-07-R

Eye Seal

7

03-0651-09-R

J Flange 3-10 butt

03-0854-04-R

JCM Flange 2-1/21-8 butt

7a

11-1517-01-R

SKM Flange 2-1/2” butt with 1/4’ plug 31160906R

8

14-1266-35-R

Fastener 1/4-20x3/4 4 required, Eff, for units prior to 2/1/94 “J” model

14-4339-08-R

J, JCM and SKM Fastener 1/4-14 x 1-1/8

Содержание S - J Series

Страница 1: ...ur pump or in this manual look for one of the following signal words and be alert to the potential for personal injury D A N G E R warns about hazards that will cause serious personal injury death or major property damage if ignored WARNING warns about hazards that can cause serious personal injury death or major property damage if ignored CAUTION warns about hazards that will or can cause minor p...

Страница 2: ...d be done in accordance with applicable codes by competent electrician We recommend the installation of a ground fault circuit interrupter for maximum safety PVC PVC JOINT PVC ABS JOINT Uni weld Pool Tite 2000 Uni weld Pool Tite 2000 Suregard Flex 20 Suregard Weld all No 5 IPS Weld on 705 IPS Weld on 794 PUMP START UP Fill tub to desired level making sure that suction fittings and jets are below w...

Страница 3: ...r discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or disharge line too small 4 Pump running at reduced speed see above 5 Impeller clogged LOW PUMP PRESSURE 1 Pump running at reduced speed see motor 2 Discharge valve or inlet fittings open too wide HIGH PUMP PRESSURE 1 Discharge valve or inlet fittings closed too much 2 Return lines too small NOISY PUMP AND MOTOR 1...

Страница 4: ... eff prior 2 1 94 1 4 20 Thrd 2 1 2 butt 3 47 0357 46 R O ring 5 1 2 x 5 7 8 x 3 16 4 10 0002 06 R 5 8 Mechanical Seal 5 05 3862 06 R Impeller S7J S7K 11343 3 45D 05 3863 05 R Impeller S1J S1K 11343 3 73D 05 3864 04 R Impeller S15J S15K 11343 4 10D 05 3865 03 R Impeller S2J S2K 11304 4 22D 6 10 1462 07 R Eye Seal 7 03 0651 09 R J Flange 3 10 butt 03 0854 04 R JCM Flange 2 1 21 8 butt 7a 11 1517 01...

Страница 5: ...m has received the product at our factory Replacement or repair cannot be made until after the product is inspected All charges or expenses for freight to and from the factory removal and reinstallation of the product or installation of a replacement product are the responsibility of the purchaser THIS WARRANTY SUPERSEDES ANY WARRANTY NOT DATED OR BEARING AN EARLIER DATE ANY IMPLIED WARRANTIES WHI...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Отзывы: