background image

 1 of 2

Colibri System Board 

Field Replacement Instructions

Tools Needed

•   ¼ Inch nut driver  
•   #2 Phillips screwdriver.

Backup Settings

If replacing a board that can still communicate, connect to 

it and download setup, registration file and database. 
To backup the data, use the TSA Upgrade tool. Refer 

to INCON document 000-0075 for information about 

downloading and using the upgrade tool. Individually 

select the tabs Registration, Setup and Database and in 

each case click Save.

 

Figure 1: Upgrade Tool Screen

Removing Existing System Board

1.  Remove electrical power from unit at the breaker.
2.  Remove the front cover from the unit.
3.  Disconnect the plugs from the Power, Relay and 

Probe receptacles and any communication cables 

or USB sticks attached to communication ports.

4.  Loosen the two screws on the left hand side of the 

power brick (1 and 2 in Figure 2). Do not pull the 

screws out.

5.  Remove the two screws on the right hand side of 

the board (4 and 5 in Figure 2) and set them aside 

with the Intrinsically Safe shield and the display 

ground strap. 

6.  Remove the standoffs from the top right and bottom 

left corners of the board (3 and 4 in Figure 2).

7.  Grasp the board and gently pull out from the top. 

Once the top portion is an inch or so from the 

enclosure gently lift the board up and out of the 

enclosure. 

Before placing the replacement board in the enclosure, 

first remove the two lock nuts from the left hand side of the 

power block/brick (1 and 2 in Figure 2) being careful that 

the screws do not drop out. Use the two nuts to secure the 

two screws on the unit that was removed. There will also 

be a locknut under the standoff in location 4. 
The replacement board that is being installed will be one of 

two types: 
•   CL-MBXX  Spare controller module, Fuel Management 

System Application only, no software options

•   CL-MBXX  Replacement controller module, factory 

programmed with the systems required options

If the system is having the board replaced with a spare 

module, the board may need to be upgraded to regain 

either SCALD or TRAC software options. This is only if the 

original system had these software options included.
The TSA Upgrade tool can be used to upgrade the CL-

MBXX. For assistance with upgrades, contact the FFS 

Technical Support Team.
If the CL-MBXX is ordered for the correct serial number 

of the system, the board will have the necessary software 

options installed. This will be a “plug and play” board 

replacement.

Part #

Description

CL-MB

CL6 Replacement mainboard, no display

CL-MB/R

CL6 Replacement mainboard, no display 

with required options

CL-MBWD

CL6 Replacement mainboard with display

CL-MBWD/R CL6 Replacement mainboard with display 

and required options