This product is intended to reduce electromagnetic interference (EMI).
Its use should be considered only if interference remains after best wir-
ing and grounding practices have been implemented at the location.
Because of the variety of equipment locations, power wiring methods,
and grounding practices, it is impossible to ensure a specific amount
of interference suppression. Although Franklin Electric has performed
laboratory tests that show significant EMI reduction with this filter, we
cannot predict the performance of this product in the field.
Refer to the SubDrive/MonoDrive Utility Installation Manual for de-
tailed setup and safety information, refer to
www.franklinwater.com
.
Installation
Remove System Power
Risk of severe injury or death by electrical
shock.
•
Disconnect and lock out all power before installing or servic-
ing equipment.
•
Capacitors inside the drive and the filter can still hold a lethal
voltage even after power has been removed — ALLOW FIVE
MINUTES FOR DANGEROUS INTERNAL VOLTAGES TO
DISCHARGE.
Risk of bodily injury or damage to pump or other
equipment.
•
This product should only be used with the Franklin Elec-
tric drive models SubDrive Utility (UT3P) 5870202303 and
5870202303XD, or MonoDrive (UT3W) 5870202203..
Mounting
The SubDrive/MonoDrive Utility System Filter is supplied in a NEMA 3R enclosure. Appropriate cables and cable fittings must
be used in the installation to maintain the NEMA 3R rating.
1. Remove the thumbscrew from the bottom front cover of the System Filter.
2. Remove the cover from the System Filter.
3.
Mount the System Filter to a flat surface using three screws (not included). Insert one screw through the top flange hole,
and then two screws into two internal mounting holes.
Electrical Connections
Remove System Power
1.
Disconnect electrical power to the controller at the main breaker. If previously connected to the supply mains, wait five (5)
minutes for dangerous internal voltages within the controller to discharge.
2. Remove the cover from the SubDrive/MonoDrive Utility controller following instructions in the SubDrive/MonoDrive Utility
manual.
Install Wiring
(
Tighten all terminals to 5 in-lbs (0.55 Nm)
)
3. Route supply mains power and ground wires to the System Filter
Power In
terminals
L1
and
L2
(230 V) or
L
and
N
(115
V) with the green ground wire connected to the marked ground terminal.
4. Route power and ground wires from the SubDrive/MonoDrive Utility System Filter
To Drive Input
terminals
L1
and
L2
(230 V) or
L
and
N
(115 V) to the SubDrive/MonoDrive Utility controller drive input terminals
L1
and
L2
(230 V) or
L
and
N
(115 V) respectively, with the green ground wire connected to the marked ground terminals.
SubDrive/MonoDrive Utility 3 Wire & 3 Phase - System Filter
INSTALLATION GUIDE