background image

4

 10.43"

[ 265 ]

 7.00"

[

177.8

]

 8.00"

[

203.2

]

 5.72" 

[

145.2

]

 3.45"

[ 87.7 ]

ACCESS PANEL

ACCESS PANEL SCREWS

 9.31"

[

236.4

]

 2.92" [

74.1

]

 6.65" [168.9

]

 1.50"
[ 38.1 ]

INPUT

POWER

 18.84"

[ 478.5 ]

 17.32"

[ 439.9 ]

1-1/4" NPT

SUCTION

1-1/4" NPT

DISCHARGE

FIGURE 1: 

TYPICAL INSTALLATION
The Inline System is designed to both increase a system’s incoming pressure, and to provide the system with constant 
pressure across all outlets. See 

FIGURE 2 for a graphical representation of what a typical installation may look like. 

Ball

Valve

Check

Valve

Ball

Valve

Union

Coupling

Union

Coupling

To Home

Water Supply

Inline System

Pressure
Shut-off

Sensor

(optional)

2 Gallon

Tank

Check

Valve

Power

Ball

Valve

Pressure

Sensor

(Discharge into drain 

rated for max pump 

output at relief pressure)

Pressure 

Relief

Valve

Pressure 

Gauge

Flow

Optional Bypass

5 feet or Less

*Check

 Valve

FIGURE 2: 

*NOTICE: If system plumbing does not have a backflow prevention device, a check valve is required on the incoming   
water supply line.
NOTE: These optional components are shown in a typical installation diagram. They should be used at the installer’s    
discretion as required for particular applications. 

 

Содержание SubDrive Inline 1100

Страница 1: ...dous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNI NG TERMINAL USING WIRE NO SMALLER THAN MOTOR CABLE WIRES TO REDUCE RISK OF ELECTRICAL SHOCK DIS...

Страница 2: ...60 PSI 4 1 bar Stainless steel construction for all wetted surfaces Drive Controller Protection Features No in rush power on transient current Over pressure shut off optional See Replacement Parts Section Low water shut off Locked pump detection shut off High voltage lightning surge protection Low line voltage protection Motor under and overload protection Open and short circuit protection NEMA 4 ...

Страница 3: ...roller will try to restart when the fault condition subsides INSTALLATION LOCATION OF THE Inline Constant Pressure System Decide on a location for the pump installation that is suitable based on the enclosure rating of the Inline System WARNING Liquid tight conduit and fittings must be used to maintain NEMA 4 rating Choose a clean well ventilated location that provides protection from freezing flo...

Страница 4: ... electrical power at the main breaker 2 Drain the system if applicable 3 Mount the Inline System in the desired location using mounting screws Screw locations are shown in FIGURE 1 The Inline System may be installed in any orientation 4 Install inlet and outlet plumbing and pressure tank as shown in FIGURE 2 A check valve must be installed in the inlet and outlet plumbing The outlet check valve sh...

Страница 5: ...y look like Ball Valve Check Valve Ball Valve Union Coupling Union Coupling To Home Water Supply Inline System Pressure Shut off Sensor optional 2 Gallon Tank Check Valve Power Ball Valve Pressure Sensor Discharge into drain rated for max pump output at relief pressure Pressure Relief Valve Pressure Gauge Flow Optional Bypass 5 feet or Less Check Valve Figure 2 NOTICE If system plumbing does not h...

Страница 6: ...PERATION RATINGS CAUTION Maximum operating pressure should be limited to whatever level is needed to protect the rest of the existing system plumbing When required a pressure relief valve should be installed and or the optional over pressure sensor can be used Maximum suction pressure is 70 psi 4 8 bar Maximum water temperature is 104 F 40 C Avoid pumping abrasive or sandy water WARNING Hazardous ...

Страница 7: ...s the steady flow feature reduces the controller s reaction time to sudden changes in flow If it is necessary to adjust the pressure control remove power and allow the controller to discharge Wait 5 minutes to allow internal voltage to dissipate locate the DIP switch bank Use a small screwdriver provided to move position 2 to ON as shown restrictions in the plumbing and will be more pronounced the...

Страница 8: ...to pump before servicing unit DRAINING NOTICE Disconnecting the pump will not necessarily drain all other parts of the piping system If there are any concerns with the proper procedure or necessity of draining the suction plumbing contact a water systems professional All piping and water tanks exposed to freezing weather should be drained If there are any concerns with the proper procedure to drai...

Страница 9: ...8 Overpressure Switch H 305707909 19 2 Gallon Pump Tank Kit I 305707910 1 Item ships with fastener kit D REPLACEMENT PARTS CONTINUED Spare Parts Kits for Inline 1100 LG Number Description Kit Grouping Identifier Repair Part Order Codes 1 Drive Assembly A 305707907 2 Mounting Posts 3 Pump Motor Assembly B 305707902 4 Mounting Feet C 305707903 5 10 24x1 625 Pan Head Torx D 305707904 6 10 Lock Washer...

Страница 10: ... N A 5 OPEN MOTOR CIRCUIT Loose motor connection Wires to motor are open circuit Check motor connection 6 SHORT CIRCUIT When fault is indicated immediately after power up Short circuit due to defective cable motor or drive Check motor connections Replace drive or motor 7 OVERHEATED DRIVE High ambient temperature Improper ventilation Clogged heat sink Ambient temperature has exceeded 104 F 40 C Shi...

Страница 11: ...Curves 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 Feet M 3 PH GPM LPM Meters PSI Recommended Continuous Operating Range 0 10 20 30 40 50 0 20 40 60 80 100 120 140 160 180 0 1 2 3 4 5 6 7 8 9 10 11 0 20 40 60 80 100 120 140 160 180 ...

Страница 12: ... 15 8 103 56 6 18 0 87 7 1 1 4 Schedule 40 pipe 1 380 in i d Type L Copper tube 1 265 in i d GPM Velocity Ft S Friction Loss Ft Hd 100 of pipe Velocity Ft S Ft Hd 100 Pipe Fric Loss C 130 Steel C 100 PVC C 140 4 0 0 86 0 56 0 30 1 02 0 52 6 0 1 29 1 20 0 65 1 53 1 12 8 0 1 72 2 04 1 10 2 04 1 92 10 2 15 3 08 1 67 2 55 2 90 12 2 57 4 31 2 33 3 06 4 04 14 2 00 5 73 3 10 3 57 5 35 16 3 43 7 34 3 96 4...

Страница 13: ...or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums as set forth in the product instructions NEITHER SELLER NOR THE COMPANY SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQ...

Отзывы: