INSTALLATION AND SETUP
Installation Process
12
Standard Submersible Constant Pressure System
The above drawing illustrates how a typical submersible pump system should be arranged for a
constant pressure application.
1.
Pump and Franklin Electric Motor.
Refer to the Franklin Electric AIM Manual for pump, pipe,
and cable sizing information.
2. Check Valve
3.
Pressure Relief Valve:
Pressure relief valve must be able to pass full pump flow at 100 PSI.
4.
Pressure Tank:
Refer to
“Minimum Pressure Tank and Supply Pipe Sizing” on page
13
.
5. Pressure Gauge
6.
Pressure Sensor or transducer:
Install in a vertical position.
7.
MonoDrive Utility VFD
8.
Power Supply from Circuit Breaker.
Single phase, 230 VAC
±
10%.
9.
Power to Motor:
Single phase.
A tank tee is recommended for mounting the tank, pressure sensor, pressure gauge, and pressure
relief valve. If a tank tee is not used, the pressure sensor or pressure transducer should be within 6
feet (1.8 meters) of the pressure tank to minimize pressure fluctuations. There should be no elbows
between the tank and pressure sensor.
Risk of bodily injury or property damage.
•
Pumps can develop very high pressure in some situations. Always install a pressure relief
valve able to pass full pump flow at 100 psi.
•
Install the pressure relief valve near the pressure tank and route to a drain capable of full sys-
tem flow.
Содержание MONODRIVE UTILITY UT3W
Страница 1: ...MONODRIVEUTILITY Owner s Manual ...
Страница 41: ...MONODRIVEUTILITY Manuel d utilisation ...
Страница 81: ...REMARQUES Normes en vigueur 41 REMARQUES ...
Страница 82: ...REMARQUES Normes en vigueur 42 REMARQUES ...
Страница 85: ...MONODRIVEUTILITY Manual del propietario ...
Страница 125: ...NOTAS Estándares aplicables 41 NOTAS ...
Страница 126: ...NOTAS Estándares aplicables 42 NOTAS ...