This instruction sheet provides you with the information required to safely own 

and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and 

material, and has been engineered to give you long and reliable service. This 

product has been carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your item(s) carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.
ReAd  THeSe  INSTRUCTIoNS  CAReFUllY  BeFoRe  ATTeMPTING  To 

INSTAll, oPeRATe, oR SeRVICe YoUR PRodUCT. KNoW THe PRodUCT’S 

APPlICATIoN,  lIMITATIoNS,  ANd  PoTeNTIAl  HAZARdS.  PRoTeCT 

YoURSelF  ANd  oTHeRS  BY  oBSeRVING  All  SAFeTY  INFoRMATIoN. 

FAIlURe  To  CoMPlY  WITH  THeSe  INSTRUCTIoNS  CoUld  ReSUlT  IN 

PeRSoNAl INJURY ANd/oR PRoPeRTY dAMAGe!

 deClARATIoN oF CoNFoRMITY

We, Franklin Electric, declare that our pumps TPR, TPT & TPS with pump type 

and serial number as shown on the nameplate are constructed in accordance 

with Directives 2006/95/EC and 89/336/EEC and assume full responsibility for 

conformity with the standards laid down therein.

deSCRIPTIoN

Your Little Giant peristaltic condensate pump is designed as a fully automatic 

condensate removal system for the water dripping off an air conditioner 

evaporator coil. The pump is not for contiuous use applications. The pump you 

have purchased is a small but powerful drain pump for the positive displacement 

of condensate from fan coils and air conditioners. The design of this pump allows 

the air handler to be located away from gravity water drains since the condensate 

can be pumped to a common drain a distance away. The peristaltic pump is 

designed to remove condensation from fan coil, wall-mount, ceiling and cassette 

air conditioning equipment. 

SAFeTY GUIdelINeS

SHUT oFF eleCTRICAl PoWeR AT FUSe BoX BeFoRe ATTeMPTING To 

SeRVICe, dISCoNNeCT, CoNNeCT oR ReMoVe ANY CoMPoNeNT!
 1.  This pump is not to be used to pump flammable or explosive fluids such 

as gasoline, fuel oil, kerosene, etc. Do not use this pump in explosive 

atmospheres.

 2.  Do not handle pump with wet hands or when standing on a wet, damp 

surface or when standing in water.

 3.  In any installation where property damage and/or personal injury might result 

from an inoperative or leaking pump due to power outages, discharge line 

blockage, or any other reason, a backup system(s) and/or alarm should be 

used.

 4.  Support pump and piping when assembling and when installed. Failure to 

do so may cause piping to break, pump to fail, motor bearing failures, etc; or 

may cause the pump to malfunction.

 5.  Place pump in an area where there is no danger of ingress of water.

SPeCIFICATIoNS

Maximum suction head: 

2m (6.5 ft)

Maximum delivery head: 

14m (49 ft)

Maximum ambient temperature: 50°C (122°)

PRe-INSTAllATIoN

 1.  Check the pump label for proper voltage and frequency required. Do not 

connect to voltage and frequency other than that shown.

 2.  It is recommended to use ¼” I.D. or 6 mm I.D. tubing for both the inlet and 

outlet. Inlet tubing is connected to the inlet fitting identified by an upward 

arrow. Outlet or discharge tubing is connected to the outlet fitting identified 

by a downward arrow.

 3.  Make sure the transparent cover is closed before operating.

INSTAllATIoN

Pump Mounting Installation:
The pump can be mounted adjacent, below or above (but not more than 2m 

above) the condensate water source.
For best results, mount the pump with the hose connections facing down as 

shown in Figure 1B. 

A

B

C

D

FIGURe 1

The pump may also be positioned on any side, but not placed rotor downward 

(Figure 1C) or upward (Figure 1A). Connect 6.0mm or 1/4” tubing (not provided) 

to the pump intake indicated by the arrow pointing upward on the transparent 

cover. Position the other end of the intake tube in the drip tray drain hose and 

seal it accordingly or place the intake tube in the drip tray (Figure 2). Be careful 

not to twist, kink, or collapse the tubing. Run a length of 6.0mm or ¼” tubing (not 

provided) from the discharge of the pump to a gravity drain. Refer to Figure 2 for 

maximum vertical and horizontal discharge capabilities.

"Your Solution Innovator"

TPT

16 ft (5 m) 

max

98 ft (30 m) 

max

46 ft (14 m) 

max

Lt. blue

Brown

Alternative position for inlet tube

To pump

Internal 
drain tray

Inlet tube fixed 
inside tray 
outlet with 
sealant

Ceiling

Red end: room air 
sensor, intake air

Blue end: cold air 
sensor, intake air

Coil

Block off unit drain

Internal drain tray

Wall or below ceiling A/C unit

6.5 ft (2 m) max

FIGURe 2

CAUTIoN: Be certain that there are no sharp bends or kinks in the suction and 

discharge tubing. Keep all tubing and cables clear of moving parts in the air 

handler. If using Ty-raps to secure tubing, be certain the Ty-rap does not collapse 

tubing.
Collection Reservoir Installation (R Series only):
Locate the float reservoir in a suitable position below the bottom level of the drip 

tray of the air conditioner. Be certain that the reservoir is within (+/-) 15 degrees 

of being level. Optimum performance is achieved when the reservoir is level. If the 

reservoir is not mounted properly, the float mechanism may not function properly 

and may overflow.
Attach the 13mm (1/2”) tube (provided) to the reservoir intake and the drip tray 

outlet or drain hose. Be certain to support the reservoir when attaching tubing 

and make sure the tubing is not twisted, kinked or collapsed when reservoir is 

in place. Connect the long 4 x 6 mm (5/32”) tubing (provided)to the discharge 

of the reservoir marked “PUMP”. Connect the other end of the 4 x 6 mm (5/32”) 

tubing to the provided 4 x 6 mm adapter. Use a short piece of 6 mm or ¼” tubing 

(not provided) to connect the 4 x 6 mm adapter to the pump inlet fitting identified 

by an upward arrow. Connect the short 4 x 6 mm (5/32”) tubing (provided) to 

the outlet of the reservoir marked “VENT”. The free end of the tubing must be 

directed upward above the drip tray to prevent overflow. Be certain the tubing is 

not twisted, kinked or collapsed when installed.

eleCTRICAl CoNNeCTIoNS

SHUT OFF ELECTRICAL POWER AT FUSE BOX BEFORE MAKING ANY 

CONNECTIONS. ALL WIRING MUST COMPLY WITH LOCAL CODES. CHECK 

THE PUMP LABEL FOR PROPER VOLTAGE REQUIRED. DO NOT CONNECT TO 

VOLTAGE OTHER THAN THAT SHOWN.
TPS Series (compressor or cooling signal) - Connect the brown wire to the main 

phase (line), the blue wire to the neutral phase (common). The pump must not 

be connected to a switched line. Electricity should always be provided on this 

line. Connect the orange wire to the compressor or cooling signal (Figure 3). 

When the compressor engages, a 230V supply voltage will be sent to start the 

pump. When the compressor stops operating, the pump will not stop. The pump 

is programmed to continue operating for another 5 minutes to collect any residual 

condensate before stopping.
NoTe: The compressor or cooling signal neutral phase (common) needs to be 

the same neutral phase (common) that is used to supply power to the controller.
TPT  Series (temperature signal) FOR PROPER PUMP OPERATION, PLEASE 

FOLLOW THESE INSTRUCTIONS: Connect the brown wire to the main phase 

(line) and the blue wire to the neutral phase (common) (Figure 2). Make sure 

power is off when connecting the temperature sensor to the pump. Connect the 

sensor cable to the pump by connecting the 4-prong plug to the corresponding 

Franklin electric Co., Inc.

Oklahoma City, OK

www.LittleGiantPump.com

[email protected]

Содержание Little Giant TPS

Страница 1: ...URE 1 The pump may also be positioned on any side but not placed rotor downward Figure 1C or upward Figure 1A Connect 6 0mm or 1 4 tubing not provided to the pump intake indicated by the arrow pointin...

Страница 2: ...ASSY REPLACEMENT PARTS NOT SHOWN TUBE NATURAL RUBBER RESERVOIR ASSEMBLY USED ON MODEL FIGURE 5 Pump Tubing Replacement 1 Disconnect the pump from the power source 2 Open the transparent cover 3 To rem...

Страница 3: ...u Un r servoir niveau fournit une performance maximale Si le r servoir n est pas correctement mont le m canisme du flotteur risque de mal fonctionner et d entra ner un d bordement TPT FIGURE 2 Fixer l...

Страница 4: ...recommandations des autorit s comp tentes ESPA OL ES Esta hoja de instrucciones le proporciona la informaci n requerida para tener y operar de forma segura su producto Guarde las instrucciones para re...

Страница 5: ...ONES ELECTRICAS ADVERTENCIA APAGUE LA ENERG A EL CTRICA EN LA CAJA DE FUSIBLES ANTES DE REALIZAR CUALQUIER CONEXI N TODO EL CABLEADO DEBE CUMPLIR CON LOS C DIGOS LOCALES REVISE LA ETIQUETA DE LA BOMBA...

Страница 6: ...cuidado y aseg rese de que el anillo t rico est debidamente instalado no debe estar doblado roto o fuera de sitio Reemplazo de la tuber a de la bomba 1 Desconecte la bomba de la fuente de energ a 2 Ab...

Страница 7: ...legal rights You may have other rights which vary according to the applicable laws and regulations Where any term of this warranty is prohibited by such laws it shall be null and void but the remaind...

Страница 8: ...de cualquier herramienta suministro o equipo que sea necesario para instalar reparar o remover alg n producto III Limitaciones aplicables a esta Garant a Limitada ESTA GARANT A NO APLICA A NINGUNO DE...

Отзывы: