INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own 

and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship 

and material, and has been engineered to give you long and reliable 

service. This product has been carefully tested, inspected, and packaged 

to ensure safe delivery and operation. Please examine your item(s) 

carefully to ensure that no damage occurred during shipment. If damage 

has occurred, please contact the place of purchase. They will assist you 

in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING 

TO INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW 

THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL 

HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING 

ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE 

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR 

PROPERTY DAMAGE!

DESCRIPTION

Little Giant Big John

®

 submersible sump pumps remove water from 

sump basins in basements or crawlspaces. When water in the sump 

reaches a certain level, the sump pump turns on and removes the water 

through a discharge pipe. 
The 6-CIA-RFS pump is equipped with a remote float switch level control. 

This level control is sealed in a polypropylene float cylinder. For automatic 

operation, the pump must be plugged or wired into a remote float switch. 

Pump will run continuously if plugged directly into an electrical outlet.
When the water level rises in the sump, the float cylinder rises with it. 

When the float cylinder is at an angle of about 45 degrees (upward), the 

float switch activates and starts the pump motor.
As the water level falls, the float cylinder falls. When it reaches an angle of about 

45 degrees (downward), the switch deactivates and the pump motor stops.

SAFETY GUIDELINES

To reduce the risk of electrical shock, remove power cord from power 

supply before servicing this pump.
This pump is supplied with a grounding conductor and grounding-type 

attachment plug. To reduce the risk of electric shock, be certain that it is 

connected only to a properly grounded, grounding-type receptacle. 
Check local electrical and building codes before installation. The 

installation must be in accordance with their regulations.
Your pump is supplied with a 3-prong electrical plug. The third prong is 

to ground the pump to prevent possible electric shock hazard. Do not 

remove the third prong from the plug. A separate branch electrical circuit 

is recommended. Do not use an extension cord.
Do not oil the motor. The pump housing is sealed. A high-grade, dielectric 

oil devoid of water has been put into the motor housing at the factory. 

Use of other oil could cause serious electric shock and/or permanent 

damage to the pump.
During normal operation the pump is immersed in water. Also, during rain 

storms, water may be present in the surrounding area of the pump. Use 

caution to prevent bodily injury when working near the pump.
Remove the plug from the receptacle prior to touching, servicing, or 

repairing the pump.
To minimize possible fatal electrical shock hazard, use extreme care 

when changing fuses. Do not stand in water while changing fuses or 

insert your finger into fuse socket.
Do not operate the pump in a dry sump. This will cause the pump to become 

extremely hot, causing burns if touched and/or damage to the pump.
This pump’s motor housing is filled with a dielectric lubricant at the factory 

for optimum motor heat transfer and lifetime lubrication of the bearings. 

Use of any other lubricant could cause damage and void the warranty. This 

lubricant is non-toxic; however, if it escapes the motor housing, it should be 

removed from the surface quickly by placing newspapers or other absorbent 

material on the water surface to soak it up, so aquatic life is undisturbed.

In any installation where property damage and/or personal injury might 

result from an inoperative or leaking pump due to power outages, 

discharge line blockage, or any other reason, a backup system(s) and/or 

alarm should be used.
The motor section of this pump is permanently lubricated and sealed - do not 

attempt to open this section. Special equipment and knowledge is required 

for proper servicing of this part of your pump and may only be accomplished 

by an authorized service center or the factory. Your warranty will be void if the 

motor section is opened by unauthorized persons.

INSTALLATION

 1.  Clean any debris from sump and set pump in center of pit. A solid 

bottom will prevent clogging of the pump from sand and dirt.

 2. Connect discharge pipe and run it to the nearest sewer or surface 

outlet. Use pipe joint compound at all connections. Sump pumps 

can discharged into a house drainage system, to a dry well, a splash 

block, or to a storm drain, depending on local plumbing codes. The 

discharge pipe should be as short as possible and contain as few 

elbows as possible. The discharge pipe should be the same diameter 

as the pump discharge to reduce pipe friction losses. Smaller pipe will 

restrict capacity and reduce pump performance. The pump comes with 

1" female pipe thread discharge and a 1" FNPT reducing bushing.

 3.  Install a union in the discharge line, immediately above the sump, to 

allow for easy removal of the pump for cleaning or repair.

 4. If the piping is long, the vertical discharge is above 7 or 8 feet, or 

the sump is small, use of a check valve is recommended to prevent 

backflow of water into the sump. When a check valve is used, drill a 1/8" 

or 3/16" diameter air-bleed hole in the discharge pipe. This hole should 

be located below the floor line between the pump discharge and the 

check valve. Unless such a relief hole is provided, the pump could air 

lock and will not pump water even though it will run.

 5.  REMOTE FLOAT SWITCH INSTALLATION (6-CIA-RFS only). 

NOTE:

 

The float switch consists of a switch, a cord clamp, and a clamp 

screw. If screw is lost, use a #10-16 X 1/2" long tapping screw. 

Longer screws can crack the cover.

 a.  Attach cord clamp to pump cover as shown in switch instruction 

manual packaged with switch. Position clamp and pump handle 

as shown to allow free operation of float. Locate pump and switch 

power cords away from switch float.

 b.  Ensure that float tether length is 3½" when attached to pump. A 

tether length of 3" may be used, but is recommended only with 

a minimum sump diameter of 18". 

 c.  After desired tether length is set, hand-tighten clamp screw.
 d. Ensure pump is secure in sump and float cylinder moves 

unobstructed, without touching the sump walls or plumbing.

 6.  Tape power cords to discharge line with electricians tape. This will 

protect the cords from damage and will prevent the pump being 

pulled from the sump by its power cord.

 7. Place cover over sump. This will prevent solid debris from filling 

sump, prevent odors, and guard against accidental injury.

ELECTRICAL CONNECTIONS

 1.  Check the pump label for proper voltage required. Do not connect 

the pump to any voltage other than that shown.

 2.  Connect the power cord and float switch cord (for automatic operation) 

or power cord only (for manual operation) as shown in Figure 1.

Big John

®

 

Submersible Sump Pump • 

Pompe de Puisard Submersible • 

Bomba del Sumidero Sumergible

6-CIM-R

6-CIA-RFS

8-CIM-R

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

AUTOMATIC OPERATION • 

FONCTIONNEMENT AUTOMATIQUE • 

FUNCIONAMIENTO AUTOMÁTICO

MANUAL OPERATION • 

FONCTIONNEMENT MANUEL • 

FUNCIONAMIENTO MANUAL

Pump plug • Fiche de 
la pompe • Enchufe 
de la bomba 

Float switch plug • Fiche de 

l’interrupteur du flotteur • Enchufe 

del interruptor del flotador

Float switch plug • Fiche de 

l’interrupteur du flotteur • 

Enchufe del interruptor del 

flotador

Pump plug • Fiche de 
la pompe • Enchufe 
de la bomba 

Figure 1

Содержание Little GIANT Big John 6-CIM-R

Страница 1: ...it up so aquatic life is undisturbed In any installation where property damage and or personal injury might result from an inoperative or leaking pump due to power outages discharge line blockage or...

Страница 2: ...e dans le bo tier en usine L utilisation d un autre type d huile pourrait causer un choc lectrique grave ou gravement endommager la pompe ou les deux Durant le fonctionnement normal du syst me la pomp...

Страница 3: ...puisard est de 45 7 cm 18 po c Lorsque la longueur souhait e est obtenue visser manuellement la vis de serrage d S assurer que la pompe est fix e solidement dans le puisard et que le cylindre flottan...

Страница 4: ...ubo de descarga deber tener el mismo di metro de la descarga para reducir las p rdidas por fricci n de los tubos Un tubo m s peque o restringir el rendimiento y disminuir la capacidad de la bomba La b...

Страница 5: ...ow on check valve body to ensure it is installed properly V rifier la fl che indiquant l coulement pour s assurer que la soupape d arr t est bien mont e Inspec cione la flecha indicadora del flujo en...

Страница 6: ...Volute Volute Difusor 1 1 1 4 909021 Screw washer 10 24 x 1 2 Vis rondelle 10 24 x 1 2 Tornillo y arandela 10 24 x 1 2 5 5 5 5 108482 Intake screen cran d admission Rejilla de malla de la entrada 1 1...

Страница 7: ...lt GFCI s with various cord lengths are in stock and we recommend each product be used with a GFCI GARANTIE LIMIT E Votre produit est garanti pour tre dans la condition parfaite quand il quitte notre...

Страница 8: ...nes necesarias y resuelva el reclamo de la garant a DESAUTORIZACION LA GARANTIA ANTERIOR ES UNA GARANTIA EXCLUSIVA EN LUGAR DE CUALQUIER OTRA GARANTIA EXPRESA CUALQUIER GARANTIA IMPLICADA INCLUYENDO P...

Отзывы: